Troubleshooting
Oven Fails To Operate: No Heat
1.
If the indicator light does not illuminate, check power supply.
2.
Confirm cord is plugged fully into power inlet. Check complete power cord for
continuity. If defective, replace the entire cord.
3.
Check indicator light. Using a volt meter, confirm voltage to the light leads. If
voltage is confirmed and light does not illuminate, replace light. Please note
the indicator light is neon and cannot be checked for continuity.
4.
Disconnect heating element from the thermostat (under shell top/lid
assembly). Check heating element for continuity. If no continuity, replace
heating element.
5.
Disconnect wiring from the thermostat. Turn the thermostat knob to the
lowest temperature setting (counter-clockwise). Check for continuity through
thermostat. If no continuity, replace thermostat.
Oven Operates: Overheats, Low Heat,
Does Not Heat to Desired Temperature
1.
Check power supply to confirm voltage is within acceptable range of 120 or
240 volts AC +/-10%.
2.
Check that the voltage selector switch setting corresponds with the power
supply to be used.
3.
Check that the variable thermostat is properly set to the desired temperature.
4.
Check that enough time has been allowed for heat-up. A cold, fully loaded
oven may take up to four hours to fully heat and stabilize.
5.
Check that the variable thermostat is securely mounted. A loosely mounted
thermostat will not properly sense the oven temperature.
Thermometer Indicates in Wrong Units:
˚F or ˚C
(if equipped)
1.
Disconnect power from the unit.
2.
Remove the bottom cover from the base to expose thermometer battery
housing.
3.
Changing to either °F or °C is accomplished by pressing the button located in
the battery holder.
4.
Re-install the battery and bottom cover prior to putting the oven back in
service.
Thermometer Inoperable
(if equipped)
:
Replace Battery
Indicated by a weak or absent display.
1.
Disconnect power from the unit.
2.
Remove the bottom cover from the base.
3.
Remove the battery from the holder and replace with a fresh AA 1.5V battery.
(Alkaline batteries are recommended.) Check that display is operational. If
not, replace thermometer (part #1257420). (See Replacement Parts section
in this manual.)
4.
Re-install the battery and bottom cover prior to putting the oven back in
service.
CAUTION
•
Disconnect power before opening or servicing unit. Make sure oven is
cooled before opening or servicing unit.
•
Surfaces are hot! Use extreme care to avoid possible burns or personal
injury. Protective gloves and personal protective equipment are
recommended.
Recommended Spare Parts
Item No. Spare Part Description
Part No.
Recommended
Quantity
per 10 Ovens
1
Heating Element Kit
1257360
1
2
Variable Thermostat Kit
1257430
1
3
Locking Power Connection Kit
1257395
1
4
Indicator Light
1257400
1
5
Voltage Selector Kit
1257410
1
For users of large DryRod II oven quantities or users not in North America:
For normal daily operation, the following spare parts and quantities are
recommended to have inventoried.
1
2
3
4
5