background image

PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany

phoenixcontact.com

28/28

28

How to contact us

Internet

Up-to-date information on Phoenix Contact products and our Terms and Conditions can be 

found on the Internet at:

phoenixcontact.com

Make sure you always use the latest documentation. 

It can be downloaded at:

phoenixcontact.net/products

Subsidiaries

If there are any problems that cannot be solved using the documentation, please contact 

your Phoenix Contact subsidiary. 

Subsidiary contact information is available at 

phoenixcontact.com

.

Published by

PHOENIX CONTACT GmbH & Co. KG

Flachsmarktstraße 8

32825 Blomberg

GERMANY
PHOENIX CONTACT Development and Manufacturing, Inc.

586 Fulling Mill Road

Middletown, PA 17057 

USA
Should you have any suggestions or recommendations for improvement of the contents and 

layout of our manuals, please send your comments to:

[email protected]

Содержание TP 6000 HMI

Страница 1: ...User manual UM EN TP 6000 TP 6000 HMI for machine control...

Страница 2: ...ny phoenixcontact com 4109_en_B TP 6000 HMI for machine control This user manual is valid for Designation Order No TP 6070 WVPS 1189629 TP 6101 WXPS 1190417 TP 6121 WXPS 1190420 TP 6156 WHPS 1190421 T...

Страница 3: ...network 4 2 Overview and ordering data 5 2 1 Description 5 2 2 Ordering data 5 3 Installation 7 3 1 Mounting 7 3 1 1 Panel mount 7 3 1 2 VESA mount 10 3 2 Interfaces 11 3 2 1 Power connection 11 3 2 2...

Страница 4: ...TP 6 PS 2 28 PHOENIX CONTACT 4109_en_B...

Страница 5: ...ments This device is state of the art and has been built to the latest standard safety requirements However dangerous situations or damage to the machine itself or other property can arise from the us...

Страница 6: ...Due to its communication interfaces the device should not be used in security crit ical applications unless additional security appliances are used Therefore please take additional protective measure...

Страница 7: ...2 Ordering data Products Description Type Order No Pcs Pkt Touch panel 7 inch display TP 6070 WVPS 1189629 1 Touch panel 10 inch display TP 6101 WXPS 1190417 1 Touch panel 12 inch display TP 6121 WXP...

Страница 8: ...TP 6 PS 6 28 PHOENIX CONTACT 4109_en_B...

Страница 9: ...maintained for the mounting cutout The seal lies flat against the mounting surface The number of mounting brackets given in the technical data is used The material of the mounting surface is sufficien...

Страница 10: ...le 3 1for dimensions Table 3 1 Overall and cutout dimensions with number of mounting clamps Display size Overall dimensions Cutout dimensions1 1 Cutout dimensions are 0 5 mm Number of mounting clamps...

Страница 11: ...nel The retention clips on top and bottom of the monitor only provide temporary assis tance during installation 3 From the rear place the clamps 3 in the slots 4 on the display Clamps must be in stall...

Страница 12: ...CONTACT 4109_en_B 3 1 2 VESA mount The TP 6 PSincludes a VESA MIS D 100 C hole pattern for attachment to an appropriate mount Note that this standard is for devices up to 14 kg 30 lb Figure 3 3 VESA...

Страница 13: ...iguration environment such as Visu Express refer to Serial communication on page 13 MicroSD The microSD slot accepts use of a microSD card to transfer data to and from the TP 6 PS Typical use is for t...

Страница 14: ...roduct label as VC00 Starting with VC01 the ferrite core is built into the internal power supply A ferrite core is included with the TP 6 PS units It is required to reduce EMI interference when the de...

Страница 15: ...ation environment as either When in Visu Express the user will select the communication driver RealTimeDB and then configure the port within the station properties The function of the pins in the D SU...

Страница 16: ...TP 6 PS 14 28 PHOENIX CONTACT 4109_en_B...

Страница 17: ...2 Power LED A power LED indicates when power is available at the operating device 4 3 Display DANGER If the display is damaged avoid touching swallowing or breathing in the liquids or gases which may...

Страница 18: ...TP 6 PS 16 28 PHOENIX CONTACT 4109_en_B...

Страница 19: ...use to regenerate At an ambient temperature of 20 C 68 F the regeneration takes approximately 20 seconds The higher the ambient temperature the longer the regeneration takes 5 2 Battery replacement Th...

Страница 20: ...the battery It is held in place with double stick tape and may require a small amount of effort to remove 6 Secure the new battery in place using new double stick tape obtained locally 7 Plug the bat...

Страница 21: ...HPS TP 6185 WHPS TP 6215 WHPS 25 85 C 20 60 C Permissible humidity relative TP 6070 WVPS TP 6101 WXPS TP 6121 WXPS TP 6156 WHPS TP 6185 WHPS TP 6215 WHPS 5 85 non condensing 10 95 non condensing Weigh...

Страница 22: ...x A9 Clock speed 800 MHz Number of cores 4 Interfaces Data port 2x Type A USB 3 0 MicroSD Serial connection 1x D SUB 9 male configurable via Visu Express for RS 232 422 485 Number of Ethernet connecto...

Страница 23: ...Display size inch cm 12 1 30 7 Type TFT Resolution W x H pixels 1280 x 800 Number of colors 16 7 million Touch technology PCAP 10 point Brightness cd m 400 Backlight LED Backlight MTBF hours 50000 Vie...

Страница 24: ...size W x H mm 455 x 300 Display TP 6215 WHPS Display size inch cm 21 5 54 6 Type TFT Resolution W x H pixels 1920 x 1080 Number of colors 16 7 million Touch technology PCAP 10 point Brightness cd m 4...

Страница 25: ...of figures Section 3 Figure 3 1 Panel cutout dimensions 8 Figure 3 2 Panel mounting clamps 9 Figure 3 3 VESA mount drawing 10 Figure 3 4 Connectors and ports 11 Figure 3 5 Power connection 11 Figure...

Страница 26: ...TP 6 PS 24 28 PHOENIX CONTACT 4109_en_B...

Страница 27: ...ables 4109_en_B PHOENIX CONTACT 25 28 B 2 List of tables Section 3 Table 3 1 Overall and cutout dimensions with number of mounting clamps 8 Table 3 2 D SUB 9 pinout 13 Section 4 Table 4 1 Power LED me...

Страница 28: ...TP 6 PS 26 28 PHOENIX CONTACT 4109_en_B...

Страница 29: ...products in your specific application in particular with regard to observing the applicable standards and regulations All information made available in the technical data is supplied without any accom...

Страница 30: ...products Subsidiaries If there are any problems that cannot be solved using the documentation please contact your Phoenix Contact subsidiary Subsidiary contact information is available at phoenixconta...

Отзывы: