Troubleshooting
3433_en_C
PHOENIX CONTACT
5
Troubleshooting
5.1
Resetting the device
If, for some reason, you need to reset the module to factory settings, there are two methods
available.
Hardware reset
The reset button resets the device to the default settings, without the use of a PC, loaded
during manufacturing, including the user interface settings. Any user-loaded firmware,
including updates, is also removed.
Figure 5-1
GW PL ETH/UNI-BUS reset button
While connected to the power source:
1.
Press and hold the reset button for at least five seconds.
Reinitializing the module and firmware reset may take some time. Do not disconnect
from power.
2.
After a successful reset, the module will return to the factory default address
(192.168.254.254).
Software reset
A software reset returns the user interface settings to the default settings.
1.
Start the web server and navigate to the “Device Maintenance/Restore Defaults” page.
2.
Click the check box on the page.
3.
Click the “Apply Changes” button.
4.
After a successful reset, the module will return to the factory default address
(192.168.254.254).