PHOENIX CONTACT page 5  of  7

 

Medium Converter – FL MC 10BASE-T/FO G850

 

4. Connection Notes

6 3 7 9 A 0 1 6

Figure 07

Control cabinet mounting

6 3 7 9 A 0 1 7

1

M o n t a g e

D e m o n t a g e

2

3

3

2

1

U L  
C O L

F L   H U B   1 0 B A S E - T

O r d . - N o . 2 8 3 1 0 2 8

1

2

3

4

1

2

3

4

1

2

3

4

R E S E T

U L   1  

F L   H U B   A G E N T

O r d . - N o . 2 8 3 1 0 7 3

U L   2  
C O L

1

2

3

4

0 0 A 0 4 5 1 B D D

6 1 4 5 1 0 0 1

U L  

F L   M C   1 0 B A S E - T

                  / F O   G 8 5 0

O r d . - N o . 2 7 4 4 7 8 8

T D  

1  

R D  

2  

6 1 4 5 1 0 0 1

U L  

F L   M C   1 0 B A S E - T

                  / F O   G 8 5 0

O r d . - N o . 2 7 4 4 7 8 8

T D  

1  

R D  

2  

Figure 08

Mounting/removing the 
FL hub station

 

6.  Push the second module (from the left) along the 

DIN rail to the left until the pin strip/socket strip of 
both modules are interlatched and the sides of both 
modules lie flush with one another.

7.  Now push the other modules together from right to 

left as described above.
(Figure 08).

 

Removal:

 

1.  To remove a FL hub station, the FL module on the 

right-hand side must be pushed to the right until the 
entire pin strip/socket strip is released (Figure 08). 

2.  Pull the locking latch down using a screwdriver, 

needle-nose pliers or similar. 

3.  Pull the bottom edge of the module away from the 

mounting surface.

4.  Pull the module diagonally upwards away from the 

DIN rail.

Install the FL MC 10BASE-T/FO G850 on a DIN rail 

in accordance with DIN EN 50 022 (Phoenix Contact: 
item NS 35). To avoid contact resistance only use 
clean, corrosion-free DIN rails. End clamps should be 
mounted on both sides of the module to stop the 
terminals from slipping on the DIN rail.

 

4.1. Mounting/Removing

Mounting:

 

1.  Fasten an end clamp next to the left-hand module to 

stop the modules from slipping.

2.  Place the module onto the DIN rail from above. The 

upper holding keyway must be hooked onto the top 
edge of the DIN rail (Figure 07).

3.  Push the module from the front towards the 

mounting surface. 

4.  Once the module has been snapped on properly, 

check that it is fixed securely on the DIN rail.

5.  Snap the other modules to be contacted onto the 

DIN rail side by side.

Only mount and remove modules when 
the power supply is disconnected.
When connecting the supply voltage for 
operation in a FL hub station, please 
refer to the notes.

Attention
Disregarding this warning may result in serious 
damage to persons or property. Only qualified 
personnel may start up and operate these devices. 
According to the safety instructions in this text, 
qualified personnel are persons who are authorized 
to start up, to ground and to mark devices, systems, 
and equipment according to the standards of safety 
technology. In addition, these persons must be 
familiar with all warning instructions and maintenance 
measures in this text.
The FL MC 10BASE-T/FO G850 module is designed 
exclusively for SELV operation in accordance with 
IEC 60950/EN 60950/VDE 0805.

Connect the DIN rail to the protective 
earth ground using a grounding terminal. 
The modules are grounded when they 
are snapped onto the DIN rail. This 
ensures that the shield is effective. 
Connect the protective earth ground with 
low impedance.

Only mount and remove modules when 
the power supply is disconnected.

Note: The device can be operated individually as well 
as in modular FL hub stations. In a FL hub station, the 
order of the various module types can be freely 
selected.

Содержание FL MC 10BASE-T/FO G850

Страница 1: ...ically detects pairs of incorrectly connected receiving cables at the TP connection and corrects them using the auto polarity correction function If long distances are to be covered or if an existing glass fiber installation is used the FL MC 10BASE T FO G850 converter covers distances up to 2800 m 9186 35 ft using multimode glass fiber The connection corresponds to the ST B FOC standard The mediu...

Страница 2: ...C 10BASE T FO G850 Housing width 22 5 mm 0 886 in Type Order No Pcs Pkt FL MC 10BASE T FO G850 27 44 78 8 1 FL MC 10BASE T FO G850 for glass fibers 10 BASE T in accordance with IEEE 802 3 RJ45 shielded 10 Mbps 100 m 328 08 ft twisted pair shielded Receiving data link status B FOC ST 850 nm 2000 m 6561 68 ft glass fibers with F G 50 125 2 4 dB km 2800 m 9186 35 ft glass fibers with F G 62 5 125 3 0...

Страница 3: ...rresponds to IEC 1000 EN 55011 corresponds to CISPR11 1 Criterion A Normal operating characteristics within the specified limits 2 Criterion B Temporary adverse effects on the operating characteristics that the device corrects independently Class A Industrial application without special installation measures EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 55011 8 kV air dischar...

Страница 4: ...n 6 LED Link status FO port green 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 6 3 7 9 A 0 1 5 Figure Medium Converter FL MC 10BASE T FO G850 3 Function Elements 7 LED Receiving data FO port yellow 8 LED Link status TP port green 9 LED Receiving data TP port yellow 10 10Base T connection TP port 11 Optical fiber connection receiver 12 Optical fiber connection sender ...

Страница 5: ... on the DIN rail 4 1 Mounting Removing Mounting 1 Fasten an end clamp next to the left hand module to stop the modules from slipping 2 Place the module onto the DIN rail from above The upper holding keyway must be hooked onto the top edge of the DIN rail Figure 07 3 Push the module from the front towards the mounting surface 4 Once the module has been snapped on properly check that it is fixed sec...

Страница 6: ...r the module via terminals US1 and GND As an option an additional power supply unit can be connected to terminals US2 and GND to provide a redundant voltage supply Both US1 US2 voltages are forwarded on the backplane Figure 03 5 2 Operation in a FL Hub Station 6 Twisted Pair Interface TP Port 6 1 10Base T Interface The FL MC 10BASE T FO G850 has an Ethernet interface on the front in RJ45 format to...

Страница 7: ...be exceeded ST is a registered trademark of AT T 7 2 Diagnostic Indicators Link Control Optical Fiber Path FO The line monitoring checks the connected cable segment for an interrupt To do this the partner must send link or data signals The LED green lights up if no error has occurred An interface that is not being used or a terminal device that is switched off is indicated as an error and the LED ...

Отзывы: