Connecting the power supply
when assembling the connector for the supply voltage.
•
Strip 8 mm off the cable. If necessary, fit a ferrule to the cable.
Rigid conductor/ferrule
•
Insert the conductor into the terminal point. It is clamped into place automatically.
Figure 5-3
Connecting a rigid conductor
Flexible conductor
•
Open the spring by pressing on the spring lever with a screwdriver (A in
).
•
Insert the conductor into the terminal point (B in
•
Remove the screwdriver to secure the conductor (recommended: bladed screwdriver,
blade width 2.5 mm (e.g., SZS 0,4 x 2,5 VDE, Order No. 1205037)
Figure 5-4
Connecting a flexible conductor
When using ferrules:
•
Use ferrules in accordance with the specifications in the UM EN AXL F SYS INST
user manual.
•
Make sure that the ferrules are crimped correctly.