![Phoenix Contact 1624130 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/phoenix-contact/1624130/1624130_user-manual_1551407044.webp)
EV
-
PLCC
-
AC1
-
DC1
44 / 74
PHOENIX CONTACT
107068_en_06
4.9.2
Connecting the power supplies
Figure 4
-
10
Terminal point assignment of the plug for the 24 V supply voltage
Figure 4
-
11
Connecting the 24 V supply voltage
Supply the controller via external 24 V DC sources. The permissible voltage range is
19.2 V DC to 30 V DC (ripple included).
•
Connect the power supplies to the corresponding plugs as described in
.
•
Insert the plugs into the controller.
•
Switch on the power supplies.
•
Only use power supplies that are suitable for operation with capacitive loads (in
-
creased inrush current) (see
Section “Sizing of the power supply” on page 43
).
EV
CH
A
R
GE
CON
T
RO
L
X3
X4
RS232
RS485
RS485
X5
COM
X7
SD CARD
Digital OUT
X11
Digital IN
X10
SIM
ANT
UL
UM
US
FR
FF
E
RS232-1
RS232-2
RS485-1
RS485-2
CAN
GSM St.
GSM TR.
Error
Plug
Charge
PLC
Error
Plug
Charge
1.1
1.2
1.3
X1
107068A011
Power
24 V
X1
X2.1
X2.2
24 V
GND
FE
X 2.2
X 2.1
Содержание 1624130
Страница 1: ...User manual Installing and operating the EV PLCC AC1 DC1 controller...
Страница 71: ...EV PLCC AC1 DC1 72 74 PHOENIX CONTACT 107068_en_06...
Страница 74: ......