Initial startup
108413_en_06
PHOENIX CONTACT
33 / 52
4.3.2
Establishing a network connection to the device
To configure the device by means of a web browser (web-based management), you first
have to connect it to a configuration computer (see
).
Below, configuration of the device via net zone 2 (XF2) is described. (Configuration via net
zone 1 is also possible.)
Figure 4
-
3
Establishing a network connection to the device
Requirement
The device and the configuration computer (admin PC) has to be in the same subnet. An exam
-
ple of a network configuration is provided in
Procedure
•
Either directly or via the network, connect the configuration computer with a network
port XF2 of net zone 2 of the device (see
).
•
The IP setting of the configuration computer can be assigned automatically per DHCP,
or a static configuration can be made (see below).
⇒
If the configuration computer has already been configured to obtain its IP setting via
DHCP, the device automatically assigns it an IP configuration (e.g.
192.168.1.100/24) in the
factory default settings
, via net zone 2 (XF2).
Checking the IP configura
-
tion
•
Open the Windows start menu and type
“cmd”
to open a command line.
•
Enter the command “
ipconfig
” and press the Enter button.
⇒
IPv4 address
,
subnet mask
and
default gateway
of the Ethernet adapter are dis-
played.
The IP configurations used in the following example have been randomly chosen. Adapt
the IP configuration to your network environment to avoid address conflicts.
Table 4
-
1
IP configuration (example): establishing a network connection
Device
IP
Net mask
Gateway
Device
(Default setting for XF2)
192.168.1.1
24 (255.255.255.0) -
Configuration computer
(Assigned by the device per
DHCP
or
static
configuration.)
192.168.1.100 24 (255.255.255.0)
192.168.1.1
Содержание 1153079
Страница 1: ...User manual UM EN FL MGUARD 1000 FL MGUARD 1000 Installation and startup...
Страница 10: ...FL MGUARD 1000 product family 10 52 PHOENIX CONTACT 108413_en_06...
Страница 28: ...FL MGUARD 1000 product family 28 52 PHOENIX CONTACT 108413_en_06...
Страница 50: ...FL MGUARD 1000 product family 50 52 PHOENIX CONTACT 108413_en_06...
Страница 53: ......