Phoebus ICM-120 Скачать руководство пользователя страница 7

TECHNICAL DATA

I.

36 Chip Micro Lens LED Array Module

The 

Ichip Mystére 

uses 

a

 

5600K, 90 CRI 36 chip Micro lens LED Array Module. 

 The

 

internally mounted ballast

 

is used to operate the 

LED Module

 from standard 120 volts.

 

The 

L

ED array module

 life

span

 is

 on

 average of 

6000

 hours

. H

owever at normal use it is

 

rated 

well beyond

 

6000

 hrs.

 Once the LED module reaches the 6000 hour mark, one or

 

two of the LED Micro chips may expire.  However this will not noticeably effect the light

 

output of the Ichip Mystére, which will continue to operate well past the 6000 hour mark.

 

CRI (color rendering index) is a measure of how accurately a light source illuminates

 

objects' true colors. Our LED modules have a CRI value of 90, indicating that 

the 

modules are able to produce white light that approximates halogen or incandescent

 

lighting and natural daylight. 

The 

LED Module

 is cooled by 

two specially designed

 fan

to 

insure 

cool and quiet 

o

peration. One

 

fan is chassis mounted 

below the 

LED module while the

 

second fan is mounted directly onto LED Module

.  Th

e

 fan

s

 

are

 essential to lamp

 

operation.  Improper cooling will cause decreased 

LED module

 life. 

A

llow 

LED

 

Module

 to

 

cool before cutting power.

II.

ELECTRIC

AL

 

I. LED Module Replacement

 I

nstallation

1.

Turn off and unplug unit.

2. Remove

 the eight 

carry handle mount screws and four housing mount screws

located 

on both sides of housing.

3.

Remove the two 

black 

control handle 

knobs

 from the

 control shafts

.

4.

Lift and remove housing from chassis.

5.

Unscrew the 

four LED module cooling fan button head screws followed by the four

LED module

 

Button head mount screws.  For easier access to the LED module

mount screws, The LED module mount bracket may be removed by unscrewing the

four phillips screws located on the underside of the chassis.

6. Replace the LED module and LED module cooling fan by reversing the above 

steps

Ichip Mystére

ICM-150/120 User Manual

5

The I

chip Mystére

 operates on 1

10

 to 12

0

V 50/60Hz A.C. 

and

 draw

s Less than

 7 amps

(replace using 7A 3AB Bussman fuse

) Located at

 the

 rear

 inside

 of the 

unit

 

you will find 

the    internally  mounted

 

Ballast  used  to  supply  the  lamp  with  the  proper  voltage  and 

current.  

There are no user

 

serviceable parts located on this ballast!!  

Refer to the 

trouble  shooting  guide  located

 

on  page  6  of  this  manual,  or  contact  the  local  dealer/ 

representative in your area.

MAINTENANCE

Содержание ICM-120

Страница 1: ...Ichip Myst re LED FOLLOWSPOT USER MANUAL MODEL ICM 150 120 PHOEBUS MANUFACTURING 1029 Washington St San Carlos CA 94070 U S A 650 591 9905 TEL 650 591 1778 FAX www phoebus com...

Страница 2: ...2 BASIC SETUP AND ASSEMBLY 2 3 4 OPTICAL SYSTEM OPERATION I SET UP AND FOCUSING 4 II BEAM CONTROL 4 TECHNICAL DATA I LAMP 5 II ELECTRICAL 5 MAINTENANCE I LAMP INSTALLATION 5 II LENS CLEANING 6 III COL...

Страница 3: ...th this manual Cause of defect is in the sole judgement of Phoebus Manufacturing This warranty is voidable at Phoebus Manufacturing s option under the following circumstances User makes unauthorized m...

Страница 4: ...to the dowser and iris assembly with black knob 2 medium Brake washers 2 small brake washers Off circuit one cooling Circuit two on 3AB 7AMP Used to focus image Turn handle clockwise to lock and count...

Страница 5: ...read handle into the bail until it is flushed to the yoke weld nut on the other side of the bail Spread washers fully apart so that the yoke can be inserted between them 4 Lift the Ichip Myst re using...

Страница 6: ...Move rear lens until edge of pattern is in focus Position may be adjusted for hard or soft edge 6 Close down the iris by moving its control handle away from the operator 7 Focused may change slightly...

Страница 7: ...on Improper cooling will cause decreased LED module life Allow LED Module to cool before cutting power II ELECTRICAL I LED Module Replacement Installation 1 Turn off and unplug unit 2 Remove the eight...

Страница 8: ...lors The lefthand operator right holders should be used for deep blue or purple gels 11 Replace boomerang assembly and secure with four thumbscrews IV LUBRICATION 1 Remove housing carry handles and mo...

Страница 9: ...3d 3e 3f 3g 3h 345 0001 1k 3a 3b 2a 2b 2c 2d 2e 2f 2g 2h 2i 2j 2k 2m 2n 2o 2p 2q 2r 2s 2t 2u 2v 1c 1d 1e 1f 1g 1m 1n 1o 1p 1h 1i 1j 1l 1a PARTS LAYOUT CHASSIS AND HOUSING Ichip Myst re ICM 150 120 Us...

Страница 10: ...8 6a 6b 6c 6d 6e 6f 6g 4a 4b 4c 4d 4e 4f 4g 5a 5b 5c 5d 5e 5f 5g 5h 5i 5j 5k 5l Ichip Myst re ICM 150 120 User Manual PARTS LAYOUT BASE COLORBOOM DOUSER ASSEMBLIES 5j...

Страница 11: ...sembly ICM 015A 1 425 00 2t Fibre Lens Handle washer ICM 771 83L 2 4 75 2u Steel Lens Washer ICM 1420 2 1 00 2v Lens Control Handle ICM 5K51 2 15 00 Serial Number Plate ICM ICMSP 1 12 00 3b Chassis Gu...

Страница 12: ...URCHASE DEALER NAME USER S NAME COMPANY NAME STREET ADDRESS CITY STATE ZIP TELEPHONE FAX EMAIL Please fold along the dotted lines and staple with return address on the outside as shown above Thank you...

Отзывы: