1 7 |
P a g e
Nightlight level
The controller recognizes "day" and "night" based on the solar PV array open circuit voltage. The daylight threshold can
be modified according to the requirements of the local conditions and the solar PV array used.
To find the exact values, we recommend measuring the PV solar array "open circuit voltage" at twilight and when the
controller is expected to switch the loads "on" or "off". This value (the closest setting available) can then be set accordin g
to the description presented in the programming section.
Technical Data
Note: The voltage levels before/after the slash are valid for 12 V and 24 V systems respectively.
Technical Data
CIS-N-MPPT 100/30
System volt age
12/24 V auto recognition
Max. charge current
30 A*
Max. load current
30 A*
Max. usable PV power
450 W (12 V system), 900 W (24 V system)
Max. PV array power
675 Wp (12 V system), 1350 Wp (24 V system)
Power conversion efficiency
Up to 98%
Float charge
13.8/27.6 V (25 °
C)
Main charge
14.4/28.8 V (25 °
C), 0.5 h daily
Boost charge
14.4/28.8 V (25 °
C), 2 h, activation: battery volt age < 12.3/24.6 V
Equalization charge
14.8/29.6 V (25 °
C), 2 h, activation: battery volt age < 12.1/24.2 V
(at least every 30 days)
Overvoltage protection
15.5/31.0 V
Open circuit volt age curve of solar array