Function explanation:
2-01
Impulse time set-up for trunk output.
2-02
Impulse time set-up for door lock.
2-03
Impulse time set-up for door unlock.
2-06
Using this function, you can set the lights control by the alarm mode.
- normal – mainly for direct control of hazard lights by (-) or (+).
- 1-2 mode – designed to control hazard lights by the button (see page 36).
2-08
Duration of negative impulse for AUX output No.1 (grounded when activated)
2-09
Duration of negative impulse for AUX output No.2 (grounded when activated)
2-11
It allows you to deactivate a shock sensor by using additional outputs in case
connected device is causing sensor reaction.
2-13
When function is disabled then is not possible to arm or disarm alarm by original remote
control only by system remote control. When function is enabled alarm will be armed or
disarmed by original and system remote control. Alarm must be connected to CAN bus via
CAN BUS Magicar module.
Programming menu RESET
In case you wish to set all the function back to the pre-set, you can do so by the following way.
All the functions will be set to option 1.
Procedure:
1. Turn the ignition on and open the door.
2. For resetting the programming menu No.1, keep buttons
l
+
ll
pressed for 2 seconds.
For resetting the programming menu No.2, keep buttons
l
+
lV
pressed for 2 seconds.
3. Lights will flash and siren will beep once.
4. Within 2 sec. press the button
III
. Lights will flash and siren will beep once.
Press button
III
again. Lights will flash and siren will beep once.
Press button
III
again. Lights will flash and siren will beep once.
5. After few seconds siren will beep 3 times and the lights will flash 3 times to confirm the
reset of the programming menu.
VI. CALIBRATION OF THE FUNCTION – HAZARD LIGHT MODE
In case
it is not possible to control hazard lights directly for the alarm needs, you can use the
hazard light button mode. In this case the alarm, using the lights output, replaces a hazard
light switch (Fig.1). In the programming menu 2-06 you can set the continuous mode (Mode1)
and the pulse mode (Mode 2).
Output - Lights
Lights - flashing
Mode 1 – continuous
Mode 2 – pulse
Fig.1 Parking Lights output connected to the Hazard switch
Lights Control
Unit
Relay contact bypassing
the hazard light switch
Light output (CN1-3 or 4)
Common input (CN1-2)
Hazard
Lights
Switch