background image

Warning:

to prevent fire or shock hazard, do not expose

camera or monitor to rain or moisture.

The lightning flash with arrowhead
symbol, within a triangle, is intended to
alert the user to the presence of
uninsulated “dangerous voltage” within
the product’s enclosure; that may be of
sufficient magnitude to constitute a risk
of electric shock to persons.

Caution:

to reduce the risk of electric shock, do not remove

cover (or back). No user serviceable parts inside. Refer servicing
to qualified service personnel.

The exclamation mark within a triangle is
intended to alert the user to the presence
of important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.

Electro Magnetic Compatibility
(EMC)

This equipment complies with the European rules EMC
according to EN55013, EN55020 and EN50082-1.

The equipment conforms with the EMC directive and
low-voltage directive.

This device complies with EMC rules under test
conditions that included use of system cables and
connectors between system components. If you have any
problems, contact your dealer.

Warning

Any unauthorized modification to this equipment may cause
violation of the EMC rules resulting in the revocation of the
authorization to operate the equipment.

Note:

we advise you to use the following types of mains

power adapters in combination with the camera:
U.K.

Philips VCM1162/01R

EUR

Philips VCM1162/00R

Important notes for users in the U.K.

If the fitted plug is not suitable for your mains socket,
it should be removed and be replaced by an appropriate
plug.

How to replace a plug

Cut the mains plug from the lead.

Strip the sheathing so the wires will become free for
the necessary length to connect the UK-mains plug (not
supplied).

The wires in the mains lead are coloured according to
the following code: blue=neutral (N), brown=live (L).
As these colours may not correspond with the colour
markings identifying the terminals in your plug, proceed
as follows:

Connect the blue wire to the terminal marked N or
coloured black.

Connect the brown wire to the terminal marked L or
colewort red.

Caution

Do not connect either wire to the earth terminal in the
plug, marked E (or) or coloured green (or green and
yellow).

Before replacing the plug cover, make certain that the
cord grip is clamped over the sheath of the lead, not
simply over the two wires.

Fuse

If the mains plug (or adapter) contains a fuse, the value
of this fuse should be 3 Amp. Alternatively, if another
type of plug (not fused) is used, the fuse at the
distribution board should not be greater than 5 Amp.

2

Содержание VSS94705T

Страница 1: ...s resulting in the revocation of the authorization to operate the equipment Note we advise you to use the following types of mains power adapters in combination with the camera U K Philips VCM1162 01R EUR Philips VCM1162 00R Important notes for users in the U K If the fitted plug is not suitable for your mains socket it should be removed and be replaced by an appropriate plug How to replace a plug...

Страница 2: ...ing slave monitor can be connected The Colour Observation Monitor can also be used as a stand alone system In this way you can use the slave monitor as a one camera surveillance system The monitor provides an input for a Philips system camera The monitor also has an auxiliary input which can be used for any video and audio baseband signal such as a VCR playback only The following items are include...

Страница 3: ...nitor Remark When the slave monitor is not connected to a system monitor stand alone you can use this input to connect a system camera 12 Slave out slave out Output for a second or third slave monitor 13 Last in line switch slave out 1 0 Set the switch to 1 if another slave monitor is connected to this output 14 Input selection switch in slave aux With this switch you can select which input is dis...

Страница 4: ...between slave monitor and system monitor The max allowed cable length is 300m 900ft Last in line switch Set this switch to 0 when the slave out output is not used this monitor is last in line Set this switch to 1 when you connect a second slave monitor Input selection switch With this switch you can select which input is displayed on the monitor screen The slave in input is selected The slave moni...

Страница 5: ... slave monitor reproduces the camera image and sound of the camera input which triggered the alarm The blinking message AL and the camera input number is displayed at the bottom of the monitor screen A buzzer sounds for max 3 minutes 2 The system monitor is in silent mode and the slave monitor is in power save mode The system mode indication LED is red blinking 3 The system monitor is in silent mo...

Страница 6: ...ptor should be used to supply the camera see accessories The max allowed cable length is 300m 900ft Caution The plugs used for the observation system have the same dimensions as standard telephone plugs Never connect telephone equipment to the observation system Tips for maintenance Ventilation Keep ventilation openings free to avoid the monitor for overheating Do not place the monitor in the imme...

Страница 7: ...e mains Cameras lock to H V and PAL indent of the monitor Inputs 1 system interface or camera Slave monitor output 1 system interface Alarm output 4 pole screwblock N O N C contact system ground Contact rating 24VDC 2A AUX Video input BNC 1Vpp output impedance 75Ohm Audio input BNC 0 5Vpp output impedance 1kOhm System cable 4 wire dual twisted pair telephone cable Weight 11 6kg Dimensions hxwxd 32...