background image

Colour Observation Monitor

Table of contents

Page

Introduction

...............................................................................................

3

Connection and operation facilities

......................................

4

Installation

..................................................................................................

4

Placement and connection
Settings

Cable length selector
Last in line switch
Input selection switch

Operation

..................................................................................................

6

Power on/off
Power save/active

Alarm

...............................................................................................................

6

Monitor is used as slave monitor

When an alarm occurs
Reset alarm

Monitor is used as stand-alone system

Trouble shooting

System cable

.............................................................................................

7

Tips for maintenance

.........................................................................

7

English

g

Read these instructions, before putting your system in
operation.

Introduction

By purchasing our ‘Colour Observation Monitor’ you
possess an easy to operate set for expansion of your
observation and security system with more observation
posts.

Used as a slave monitor it provides the same camera
image and sound as the system monitor. The monitor is
fitted with a loop-through connector to which a
following slave monitor can be connected.

The ‘Colour Observation Monitor’ can also be used as a
stand-alone system. In this way you can use the slave
monitor as a one camera surveillance system. The
monitor provides an input for a Philips system camera.
The monitor also has an auxiliary input which can be
used for any video and audio baseband signal, such as a
VCR (playback only).

The following items are included in this kit:

1

Colour Observation Monitor

1

System cable (25m/75ft)

1

User manual

1

System monitor

2

Video recorder (VCR)

3

Slave monitor(s) (max. 3)

4

Accessary boxes (0-2 per cable)

5

Interface box

6

System cameras

7

Non system camera’s (CVBS)

8

Mains power adapter

Mains supply:

The monitor accepts a mains power voltage of
100-240V~, 50/60Hz.
When the monitor is used as a stand alone system, it
supplies a safe low-voltage (16-32V

_

) for a camera.

Colour Observation Monitor

CL 66610005_005a.AI

4

6

6

7

2

talk action

menu

_

+

next

auto

view

Colour Observation system

Colour Observation Monitor

4

4

4

4

4

4

5

8

3

1

R

A

E

N

>

<

R

A

F

R

A

E

N

>

<

R

A

F

English

3

g

Содержание VSS94705T

Страница 1: ...s resulting in the revocation of the authorization to operate the equipment Note we advise you to use the following types of mains power adapters in combination with the camera U K Philips VCM1162 01R EUR Philips VCM1162 00R Important notes for users in the U K If the fitted plug is not suitable for your mains socket it should be removed and be replaced by an appropriate plug How to replace a plug...

Страница 2: ...ing slave monitor can be connected The Colour Observation Monitor can also be used as a stand alone system In this way you can use the slave monitor as a one camera surveillance system The monitor provides an input for a Philips system camera The monitor also has an auxiliary input which can be used for any video and audio baseband signal such as a VCR playback only The following items are include...

Страница 3: ...nitor Remark When the slave monitor is not connected to a system monitor stand alone you can use this input to connect a system camera 12 Slave out slave out Output for a second or third slave monitor 13 Last in line switch slave out 1 0 Set the switch to 1 if another slave monitor is connected to this output 14 Input selection switch in slave aux With this switch you can select which input is dis...

Страница 4: ...between slave monitor and system monitor The max allowed cable length is 300m 900ft Last in line switch Set this switch to 0 when the slave out output is not used this monitor is last in line Set this switch to 1 when you connect a second slave monitor Input selection switch With this switch you can select which input is displayed on the monitor screen The slave in input is selected The slave moni...

Страница 5: ... slave monitor reproduces the camera image and sound of the camera input which triggered the alarm The blinking message AL and the camera input number is displayed at the bottom of the monitor screen A buzzer sounds for max 3 minutes 2 The system monitor is in silent mode and the slave monitor is in power save mode The system mode indication LED is red blinking 3 The system monitor is in silent mo...

Страница 6: ...ptor should be used to supply the camera see accessories The max allowed cable length is 300m 900ft Caution The plugs used for the observation system have the same dimensions as standard telephone plugs Never connect telephone equipment to the observation system Tips for maintenance Ventilation Keep ventilation openings free to avoid the monitor for overheating Do not place the monitor in the imme...

Страница 7: ...e mains Cameras lock to H V and PAL indent of the monitor Inputs 1 system interface or camera Slave monitor output 1 system interface Alarm output 4 pole screwblock N O N C contact system ground Contact rating 24VDC 2A AUX Video input BNC 1Vpp output impedance 75Ohm Audio input BNC 0 5Vpp output impedance 1kOhm System cable 4 wire dual twisted pair telephone cable Weight 11 6kg Dimensions hxwxd 32...

Отзывы: