Two alarm/action boxes or intercom boxes, which are designated to the
same camera input, have the same ‘box-number’.
If the system monitor detects two boxes with the same designation and
box number, it shows the following error message:
DOUBLE ADDRESSING
“Accessory name”
INPUT X/X
Change from one intercom box the BOX switch or the CAMERA #
switch.
Explanation:
Operation
The button on the intercom is used as (door)bell. When pushed, the
buzzer in the monitor (system & slave) sounds. The monitor (system &
slave) switches to the camera input the intercom is designated to. The
automatic camera sequence stops. If you don’t react within 3 minutes - by
pushing any button - then the monitor returns to its previous status (for
example, the automatic camera sequence continues).
The system monitor reproduces the sound received from the intercom
box (plus that of the camera the system switched to, if its microphone is
not switched off). To talk back to your visitor push
H
. The sound
received by the system monitor’s microphone is then reproduced by the
intercom.
INPUT X/X
the physical camera input numbers to
which the double addressed boxes are
connected.
11
g