170X4
9
Go to cover page
Factory mode
Access Factory Mode
Step 2 :
[Push AUTO "
" & OK "
" buttons at the same time and hold
it ] + [Press power "
" button untill comes out "Windows screen"
] => then release all buttons.
How to Get into Factory Mode Menu
Turn off monitor.
Press OK "
" button, bring up Factory mode indication as
shown in Fig 2.
Step 1 :
Step 3 :
Basic and simple instruction on the control keys.
When you press the OK button on the front control of your monitor, the
On-Screen Display (OSD) Main Controls window will pop up and you
can start making adjustments to your monitor's various features.
Front control panel
Fig. 2
Contrast adjustment (Sub-Contrast). Use this menu item to
adjust the contrast gain of pre-amp ranges from 0 to 255.
9 3 0 0 K R G B
6 5 0 0 K R G B
Color temperature gain adjustment. Use these menu items to
adjust the RGB gains of pre-amp for different color
temperatures, ranges from 0 to 255.
OFFSET R G B
Sub-Brightness adjustment. Use this menu item to adjust
the brightness level (DC-level) of pre-amp range from 0 to
255.(R/G/B ANALOG DC -level).
GAIN
R G B
R/G/B GAIN adjustment. Use this menu item to adjust
the R/G/B (GAIN) of Amp. range from 0 to 255.(R/G/B
ANALOG GAIN Values).
(PS: The Offset R G B function can be used on reduce or eliminate
snowy noise on the background when the resolution of video signal is
1280 X 1024 vertical 60Hz. Slightly increase or decrease the value
until snowy noise completely disappear.)
Hot key function: by pressing "UP" and "DOWN" key
simultaneously at User mode (or Factory mode).
-
SUB
CON:
SUB
CON:
HUDSON 170X4 V200 2003-09-23
<------
Factory mode indicator
BL
: Blacklevel value
SUB-BRI
: Brightness value range(Min Max)
SUB-CON
: Contrast value range(Min Mid Max)
SRGB-B
: Brightness of sRGB
SRGB-C
: Contrast of sRGB
Gain-m
: Minimum value of User Gain
Gain-M
: Maximum value of User Gain
AUTO-SUB : To do Auto color function
When push Menu key in white pattern
OSDTIMER : OSD time out control(sec)
VCON
: For LG 15inch panel control
IDX
: Limit current of inverter
(For 15inch panel control)
SCALER
: Read/Write scaler register
NVRAM
: Read/Write eeprom address
Panel
: AUO (AUO panel)
CPT (CPT panel)
QDI (QDI panel)
LPL (LG.Philips panel)
Factory menu
Cursor can move on gray color area
Fig. 3
Fig. 1
<---
Mean : it is not
1280 x1024
resolution now.
<---
Mean : it is running the
resolution now.
Содержание SH3L 170X4
Страница 8: ...170X4 8 Go to cover page Warning message table Warning message table ...
Страница 11: ...170X4 11 Go to cover page Wiring Diagram ...
Страница 39: ...39 9 Go to cover page Scaler C B A 170X4 ...
Страница 40: ...40 9 Go to cover page Scaler C B A 170X4 ...
Страница 44: ...44 9 Go to cover page Power C B A 170X4 ...