Volume adjustment

The PCB circuit board makes it possible to adjust the 
volume output by means of pushing the one-cup and two-
cup user controls.  How to adjust the volume output: 
1.  Make sure the boiler is fi lled properly, otherwise 

perform fi ll procedure see DFU for instructions.

2.  Switch appliance on and wait until the unit is ready to 

brew.

3.  Make sure a pod holder is placed, but without a Coffee 

POD.  (Only adjusting with plain water)

4.  Place a cup on the drip tray cover and push the one-

cup button.

5.  When the appliance has fi nished it is stabilized to 

perform the volume adjustment.

6.  Empty the cup, pod holder and push again for one cup 

setting, measure the volume output with a graduated 
beaker.  In the table you can fi nd the requirements for 
the minimum / maximum volume output cc/mL values 
depending from the country version:  (see Technical 
specifi cations)

7.  Unplug the appliance from the mains.
8.  Press the 1- and 2 cup button simultaneously and plug 

the mains on.

9.  When above step succeeded the LED will turn on 

continuously.

10.  Depending if the volume has to de- or increase you 

have to push the one- or two cup button.  Every time 
you push the 1- or 2 cup button the LED will turn 
off for 0.5 second  (feedback to user) and the pump 
time will be shortened or lengthened for 0.5 seconds 
depending which button was pushed. 

Pushing 1 cup button

 pump, time will be shorten 

with 0.5 sec is approximately − 3.5 cc/mL  (less coffee).

Pushing 2 cup button

 pump, time will be lengthen 

with 0.5 sec is approxi 3.5 cc/mL  (more 
coffee).
When the volume has to increase with 10 cc for 
example, push the 2 cup button 3 times.  The new value 
will be stored when you switch the appliance off by 
pushing the main switch  (LED will turn off).

11.  Turn appliance on again and brew one cup, measure the 

volume.  In case the volume is not within specifi cation 
repeat steps 6 - 11.

Note:

Changing a newly installed PCBA (by default delivered with 
General version settings) into a French or Spanish setting 
requires a decrease of the pump time by 2,5 seconds 
(or fi ve pushes of the 1-cup button).

Содержание Senseo Twist HD7870/10

Страница 1: ...CHNICAL INFORMATION Voltage 220 240V Frequency 50 Hz Power consumption 1450 W Standby power 0 25 W Color setting Chinese Fire Weight 2 05 Kg Dimensions H x W x D Appliance 31 5 x 24 9 x 30 8 cm F Box 36 x 29 x 29 5 cm Length of cord 80 cm Contents water reservoir 930 cc ml ACCESSORIES CRP475 01 1 cup pod holder Black HD5015 01 2 cup pod holder Black CRP862 01 Drip tray cover Black CRP872 01 Collec...

Страница 2: ...ess the 1 and 2 cup button simultaneously and plug the mains on 9 When above step succeeded the LED will turn on continuously 10 Depending if the volume has to de or increase you have to push the one or two cup button Every time you push the 1 or 2 cup button the LED will turn off for 0 5 second feedback to user and the pump time will be shortened or lengthened for 0 5 seconds depending which butt...

Страница 3: ...ing the brewhead 22 Caution the hinge spring on the back side of the appliance may come out when the brewhead lid cover is being removed When reinstalling it mind your fingers as this is a strong spring To remove the boiler 24 Caution the boiler may still be hot Remove the back cover Disconnect the Hose a to the brewhead Unhook the 3 way valve 27 from its seat on the bottom of the brewhead Unhook ...

Страница 4: ...the drip tray Repeat the process for the other side All snap hooks will come undone Please note that the water container interface is still connected to the tray panel assembly and to the pump on the base plate To access the capacitive UI PCBA Remove the back cover Remove the boiler Remove the brewhead assembly Remove the Main PCBA cover 33 Remove the PCB assembly Unscrew the two screws B holding ...

Страница 5: ...ld see the On Off light blinking very rapidly for 0 5 seconds For convenience the country selection and ME HE selection are also being displayed 1 cup button 1 2 cup button 2 cup button Press the indicated button after connecting the mains Blinking Off Blinking Off Blinking General version Boiler_empty_flag set France Spain version Country Selection ME HE Selection Mid end High end Sensor On Off b...

Страница 6: ...l switches The On Off and 1 cup LED will be ON The memory LED will be OFF when ME is selected and ON when HE is selected ME HE selection In this appliance ME Mid End should be selected Strong LED off Service step 3 Change HE ME selection value 1 Push and release the 1 cup button to change the HE ME value The strong LED will be OFF when ME is selected and ON when HE is selected 2 Repeat step 3 1 wh...

Страница 7: ...on p 4 will be ON 2 Release the button or sensor The related LED refer to the table on p 4 will be OFF Service step 2 End test 1 Disconnect mains end test program PCBA REPLACEMENT When there is the need for a PCBA replace ment the default setting of the PCBA will be Boiler empty flag SET ME HE selection Mid end Country selection General version Please follow below way of working Start End Manual p...

Страница 8: ...p black 21 22 23 24 25 4222 247 41922 4222 259 57251 4222 247 71791 4222 259 52091 4222 247 05134 Distribution disk Brew chamber assy Front housing Boiler assy NTC O ring Chinese Fire Chinese Fire TCOV7 0 230V 26 27 28 29 30 4222 259 47301 4222 259 54481 4222 247 71821 4222 247 71831 4222 247 71811 NTC assy Valve assy Screw cover Valve outlet Water container catch Lynx Grivory Chinese Fire Chinese...

Страница 9: ...HD7870 80 HD7870 81 9 12 5 6 1 2 8 7 3 4 EXPLODEDVIEW ...

Страница 10: ...HD7870 80 HD7870 81 10 12 14 16 17 18 15 a 19 20 21 EXPLODEDVIEW ...

Страница 11: ...HD7870 80 HD7870 81 11 12 22 26 25 24 23 B B A b z t s u v y x w y x w a 33 32 31 28 27 29 30 34 A EXPLODEDVIEW ...

Страница 12: ...HD7870 80 HD7870 81 12 12 AUTO OFF coffee strength select CALC u v t s z 35 39 41 42 40 38 37 36 b c c C C EXPLODEDVIEW ...

Отзывы: