background image

HD7892/00 /01

8-15

Parts list

Pos

Service code

Description

Remark

1

4222 259 65942

Padholder assy  Switch 1-cup

Deep black

110

Padholder 1-cup

120

Coff ee spout 1-cup

Deep black

2

4222 259 65952

Padholder assy  Switch 2-cup

Deep black

210

Padholder 2-cup

220

Coff ee spout 2-cup

Deep black

3

4222 247 75762

Top collector

Deep black

4

4222 247 75782

Driptray cover

Deep black

5

4222 247 75772

Driptray

Deep black

6

4222 259 67511

Filter holder assy incl. Lid

610

Filter holder lid

620

Filter holder

7

4222 259 63771

Thermal jug assy incl. Lid

Black

8

9965 100 70806

Thermal jug lid

Black

9

4222 247 75141

Coff ee spoon

10

4222 259 65932

Water container assy incl. Lid

Deep black

1010

Water container lid

Deep black

1020

Valve seal

1030

Valve spring

1040

Valve rod

1050

Float spring

1060

Float assy

1070

Water container

Transparent

11

4222 259 60072

One way valve

12

4222 247 76092

Housing

Star white

13

4222 247 59473

Sensor housing

14

4222 259 65902

Top cover assy

Deep black

1410

Top cover

Deep black

1420

Buttons rubber

1430

Buttons plastic

1440

UI house top

1450

UI PCBA

1460

UI house bottom

15

4222 259 66842

Back plate assy

Star white

1510

WC Sealing

1520

Filter

1530

WC Socket

16

4222 247 72692

Lid cover

Deep black

17

4222 259 66712

Brew chamber assy

Deep black

1710

Lid hinge cover

Содержание SENSEO HD7892/00

Страница 1: ...130 mm Pump pressure 1 bar Brewing time for a jug 8 5 min Dimensions W x D x H º Packaging 466 x 242 x 322 mm º Product 150 x 400 x 270 mm Weight º Incl packaging 2 4 kg º Product 1 75 kg Materials º Podholder Stainless steel º Podholder handle PP º Top collector Podholder spouts POM º Housing Driptray cover Back plate ABS º Water container SAN º Water container lid Driptray PP º Brewchamber botto...

Страница 2: ...2 ml 74 C 76 C French version 100 ml 69 C 73 C Measured in full Jug 7 cups 80 C Measurement specification Water spec without pod in mL Western Europe ml French ml 1 cup with 1 cup pod holder 133 10 109 10 2 cup with 1 cup pod holder 266 20 218 20 Electical diagram P NTC Fuse Fuse TCO Water level sensor N E L Boiler Pump UI PCBA Main PCBA t Functional diagram Boiler Pump 1 way valve Brew head g h e...

Страница 3: ...undo them with a small flathead screwdriver No 0 The top cover needs to be tilted forward to be removed The flat cable W from the main PCBA to the UI PCBA is still attached to the User Interface panel and can easily be unplugged The brew chamber can now be removed by unscrewing the two screws C T15 and undoing the hose connection g from the one way valve 2 To reach internal components like Boiler ...

Страница 4: ...hrough the guide on the inside of the housing and the water level sensor still connected to the inside of the housing You can now access the Boiler and Pump to remove them undo the electrical connections and hoses and reinstall in the reverse order Any Ty wrap that has been removed needs to be replaced by a new one and tightened with the specified forces 3 To replace the PCBA 3 1 Unscrew the inner...

Страница 5: ...no country selection option therefore adjust both 1 cup 2 cup recipes within the right volumes following the table page 2 For the correct procedure on Volume measurement please refer to the SENSEO Repair process How to adjust the volume output 1 cup 1 Make sure the boiler is filled properly otherwise perform the Flush before first use procedure according to the instructions in the DFU 2 Make sure ...

Страница 6: ... cup buttons to store the calibration value The 1 cup and 2 cup LEDs blink rapidly 3 times You enter automatically the 2 cup pump time adjusting step 1 cup and 2 cup buttons are on 5 2 cup adjustment a Press and release the 1 cup button to decrease the calibration value The 1 cup and 2 cup LEDs blink one time b Press and release the 2 cup button to increase the calibration value The 1 cup and 2 cu...

Страница 7: ...t temperature sensor and descale LED a Press the 1 cup button and hold it b The descale LED turns on Other LEDs and the heater are off c If the temperature sensor is connected and has the right value approx 1 5 kOhm the pump turns on d Disconnect the temperature sensor and the pump turns off e Release the 1 cup button CALC LED remain on 5 Test step 5 Test water level sensor a Press the 2 cup butto...

Страница 8: ...k 8 9965 100 70806 Thermal jug lid Black 9 4222 247 75141 Coffee spoon 10 4222 259 65932 Water container assy incl Lid Deep black 1010 Water container lid Deep black 1020 Valve seal 1030 Valve spring 1040 Valve rod 1050 Float spring 1060 Float assy 1070 Water container Transparent 11 4222 259 60072 One way valve 12 4222 247 76092 Housing Star white 13 4222 247 59473 Sensor housing 14 4222 259 6590...

Страница 9: ...2 247 08101 L bend 21 4222 240 02041 Hose clamp 22 4222 259 61291 Pressure hose assy 23 4222 247 75502 Base plate Fusion black 24 4222 247 69442 Suspension bracket 25 4222 244 50693 Tie wrap boiler 26 4222 259 37244 Pump ULKA HF 230 V 50 Hz 27 4222 247 43690 Boiler pin cover 28 Hose valve assy 29 4222 247 69552 TCO cover 30 Boiler assy TCO Metal 230 V 3010 4222 259 53272 Boiler Metal 230 V 3020 42...

Страница 10: ...HD7892 00 01 10 15 110 120 3 4 5 210 220 1 2 Exploded view ...

Страница 11: ...HD7892 00 01 11 15 8 9 6 7 610 620 Exploded view ...

Страница 12: ...HD7892 00 01 12 15 1060 1050 1030 1020 1070 1040 10 1010 Exploded view ...

Страница 13: ...HD7892 00 01 13 15 a B A g C C W g f V 13 11 1460 1420 1430 1440 1450 1410 14 1530 1510 1520 15 12 Exploded view ...

Страница 14: ...HD7892 00 01 14 15 h g 1790 1770 1750 1760 2x 1780 1720 1710 17120 17130 17140 1730 1740 16 17100 17 17110 2x Exploded view ...

Страница 15: ...HD7892 00 01 15 15 U W V Y X 19 20 21 22 23 Restrictor D Z D 18 26 c b a Z Y X 31 33 2x 32 4x d e f U 28 29 27 2x 3060 3050 3020 3010 30 3040 3030 24 25 Exploded view ...

Отзывы: