background image

9

Volume adjustment procedure

If you have replaced the PCBA for whatever reason, 
you always need to check/adjust the volume 
setting from this new PCBA. The PCBA coming from 
service has standard the WEU volume setting pre-
installed.

S

pecification table, water specification normal/

strong 1-cup SENSEO recipe:

In-cup volume 
(ml) water

1-cup (ml) 

(lower limit)

1-cup (ml) 

(upper limit)

General version

123

143

French, Spanish 
version

101

121

All countries

61

81

Due to the “Intensity select” function, the volume 
programing procedure has changed. 

For proper coffee volume adjustment, for both 
volumes normal/smooth cup 122/100 ml and 
short/strong cup 60 ml two parameters need to be 
(re-)programmed.

1.  Coffee volume 122 ml  (WEU) / 100 ml 

(French/Spain) 

(Hall sensor should be 

activated, make sure a filled water tank is 
placed on the machine)

2.  Scale factor (this scale factor, need adjustment 

to ensure that for both version 122/100 ml the 
small cup volume remains 60 ml.) 

(Hall sensor 

should be de-activated, make sure water tank 
is removed from the machine)

First setup, check current water specification:

1.  Make sure boiler, is filled with water.

2.  Switch appliance on and wait until the unit is 

ready to brew.

3.  Place a 1-cup 

pod holder without

 a Coffee 

POD.  (only adjusting with 

plain

 water)

4.  Place a cup on the drip tray cover and push the 

one-cup button.

5.  When the appliance has finished, you are able 

to perform the volume adjustment. 

Adjusting the normal 1-cup volume 
(WEU or French/Spain)

6.  Empty the cup, podholder and push again for 

one cup setting, measure the volume output 
with a graduated beaker. 
In the table above you can find the 
requirements for the minimum / maximum 
water volume output cc/ml values. 

7.  Unplug the appliance from the mains.

8.  Make sure the 

water tank

 is 

filled

 and 

placed

 

on the machine. 
(for adjusting the right parameter, the internal 

SW

 will check if the 

water level sensor

 is 

activated

 yes/no.)

9.  Press the 1- and 2-cup button simultaneously 

and plug the mains on.

10. When above step succeeded the led will turn 

on continuously.

11. Depending if the volume has to de- or increase 

you have to push the one- or two-cup button. 
Every time you push the 1- or 2 cup button 
the LED will turn off for 0.5 second (feedback 
to user) and the pump time will be shortened 
or lengthened for 0.5 seconds depending 
which button was pushed. 

Pushing 1-cup

 button pump, time will be 

shorten

 with 0.5 sec is approximately  

- 3.5 cc/mL  (less coffee) 

Pushing 2-cup

 button pump, time will be 

lengthen

 with 0.5 sec is approximately  

+ 3.5 cc/mL  (more coffee) 
When the volume has to increase with 10 cc 
for example, push the 

2-cup

 button 3 times. 

The new value will be stored when you switch 
the appliance off by pushing the on/off switch. 
(LED will turn off)

12. Turn appliance on again and brew one cup, 

measure the volume. In case the volume is not 
within specification repeat steps 6 - 12.

Functions/features explanation

Содержание Senseo HD7806/50

Страница 1: ...in d un conseil Une question sur ce produit RDV sur la communauté SAV Darty https sav darty com Déjà 1 2 million de solutions grâce à l avis des utilisateurs PHILIPS CAFETIERE HD7806 51 MANUEL D UTILISATION ...

Страница 2: ...Service Manual Senseo Original HD7806 50 HD7806 52 HD7806 51 HD7806 59 ...

Страница 3: ...product is void if you do not use genuine Philips spare parts to repair critical components of your appliance The critical components are indicated with a warning triangle in the service exploded view and or service manual HD7806 50 51 52 59 Contents General information 3 Technical information Consumer Replaceable Parts Optional accessories Technical information 4 Materials Production date or seri...

Страница 4: ...0 C 10 KΩ 0 4 KΩ T 100 C 0 8 KΩ 0 02 KΩ Consumer Replaceable Parts HD5009 01 Podholder 1 cup Black HD5010 01 Podholder 2 cup Black HD5011 01 Water container Sepia grey CP0216 01 Water container Translucent specific models CP0220 01 XL Water container Sepia grey only for HD6555 CP0217 01 Driptray cover Black CRP116 01 Driptray cover Metal only for HD6556 CRP117 01 Driptray CP0602 01 Spout CP0603 01...

Страница 5: ... normal cup 122 ml 133 10 266 10 French Spanish version normal cup 100 ml 109 20 218 20 All countries short cup 60 ml 71 10 142 10 Difference between left right volume 10 ml 10 ml Measure equipment needed Thermometer with K sensor 0 100 C 2 C Plastic cup Scale balance 0 300 g 2 g Materials Housing PP Housing ABS only for HD6556 Water container PP Brew chamber PA Spout POM Hoses Silicon Drip tray D...

Страница 6: ...5 Functional diagram Boiler Pump 3 way valve Brew head Water Container Electical diagram CONTROL PCB L N Boiler Pump M Push buttons TCO Fuse Fuse Temp Sensor Water level Sensor Technical information ...

Страница 7: ... the positions see picture 1 and lift the cover over the snap locks on both positions The cover lid can now be lifted up a little and to remove the complete cover including lever and push rod squeeze strongly with two fingers both legs of the push rod see picture 2 to each other so that the two pins will get out of the hinge position on the brew chamber To remove lever from lid cover take a screwd...

Страница 8: ...ew chamber comes loose Reassemble follow above steps backwards To reach the components placed on the base handle as follows First remove back cover brew chamber and 3 way valve Remove both Torx T15 screws see exploded view in the near of position A Bend the 2 click snap locks with a screwdriver see base and the housing can now be removed To remove the rest of the housing unlock the last 4 snap loc...

Страница 9: ...hort coffee Press the 1 cup button once for one large mild cup of coffee Select the strong short coffee recipe by double tap on the 2 cups button for a double cup of strong short coffee Press the 2 cup button once for two large mild cups of coffee Selecting the right PCBA modus Enable Disable the Intensity select feature The PCBA is standard delivered with the Intensity select feature disabled thi...

Страница 10: ...he appliance has finished you are able to perform the volume adjustment Adjusting the normal 1 cup volume WEU or French Spain 6 Empty the cup podholder and push again for one cup setting measure the volume output with a graduated beaker In the table above you can find the requirements for the minimum maximum water volume output cc ml values 7 Unplug the appliance from the mains 8 Make sure the wat...

Страница 11: ...olume is not within specification repeat steps 13 17 18 End Example table switching from WEU to French Spain specification or vice versa you need to execute below Restoring the Boiler_empty flag to production default Sometimes it is needed that the boiler of the SENSEO have to be emptied This for instance in wintertime were the possibility exists that the boiler becomes frozen during transport e g...

Страница 12: ...pliance according instruction for use Boiler NTC defect Exchange boiler NTC Too less coffee Podholder blocked Descale podholder or exchange Boiler full of scale Descale appliance according instructions for use 3 way valve defect Exchange 3 way valve None of the above Adjust the SW in the PCBA Too less coffee 1st cup Pump backflow Exchange pump Too much coffee Bypass podholder Exchange podholder Tr...

Страница 13: ... holder assy 1 cup Black HD5009 01 3 4222 259 62791 Pad holder assy 2 cup Black HD5010 01 4 4222 247 77141 Spout cover Black CP0603 01 5 4222 247 77132 Spout Black CP0602 01 6 4222 247 66481 Drip tray cover Black CP0217 01 7 4222 247 72531 Drip tray CRP117 01 8 4222 247 77601 Front cover printed Mystic blue 9 4222 247 77621 Housing Mystic blue 101 Torx T15 screw Service parts ...

Страница 14: ...rts Pos Service code Description Remark 10 Brew chamber lid 11 Lever 12 4222 247 72881 Pushrod 13 4222 240 06911 Slider spring 14 4222 247 35837 Slider 15 4222 247 07461 Brew chamber seal 16 4222 259 67752 Distributor assy Coffee boost ...

Страница 15: ...2 59 Service parts Pos Service code Description Remark Online CRP 30 4222 247 39963 Sensor housing 31 4222 259 48666 Water container Sepia Grey HD5011 01 32 4222 247 40983 Valve outlet Black 33 4222 259 60151 Back cover assy Black ...

Страница 16: ...emark 17 4222 259 59541 3 way valve 18 4222 259 65482 Boiler assy OPR 230 V 19 4222 247 75271 TCO cap for OPR boiler 20 4222 24743694 Boiler pin cap 21 4222 247 72551 Suspension bracket 22 4222 247 06511 Pressure hose 28 4222 247 05136 O ring NTC 29 4222 259 39373 NTC assy ...

Страница 17: ...3 4222 259 68452 PCB assy OPR Intensity select 230 V 24 4222 259 68401 Button frame printed Black 26 4222 259 63422 On off button printed 27 3000 016 66541 Base plate Black 34 4222 259 37248 Pump 230 V 50 Hz 35 4222 247 05191 Pump damper 36 4213 247 05256 Foot 100 4222 244 50684 Tie wrap Not shown ...

Страница 18: ...17 19 03 Version 1 1 HD7806 50 HD7806 51 HD7806 52 initial release 19 06 Version 1 2 Added new version HD7806 59 Updated Parts List Version history ...

Страница 19: ...www philips com ...