![Philips Selecon PL1 Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/philips/selecon-pl1-series/selecon-pl1-series_installation-and-user-manual_310623008.webp)
Installation & User’s Manual
PL1 LED Luminaires
6
INSTALLATION AND SET UP
INSTALLATION AND SET UP
1. Power Requirements
The PL1 LED Luminaire operates on 120 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto-
ranging power supply. Depending on supply voltage, each luminaire can draw up to 1.91 amps.
2. Connecting Power
If the unit is supplied with an AC input cable, Table 2 describes how to connect power to your PL1 LED Luminaire .
Field wiring of the PL1 LED Luminaire is straight forward. A total of 3 wires/conductors need to be brought to the
unit. The following wiring scheme is required:
Table 2:
PL1 LED Luminaire AC Input Connections
3. Connecting to the DMX512 Network
Basic DMX512 installation consists of connecting multiple PL1 LED Luminaires together (up to 30 luminaires) in
"daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX connector on
the first PL1 LED Luminaire. Another cable runs from the other DMX connector on the first unit to a DMX
connector on the next PL1 LED Luminaire (or DMX512 device to be controlled).
Table 1: PL1 LED Luminaire Voltage vs. Current
Voltage (AC)
Total Current (A)
90
1.91
100
1.72
110
1.56
120
1.43
130
1.32
140
1.23
150
1.15
160
1.07
170
1.01
180
0.96
190
0.91
200
0.86
210
0.82
220
0.78
230
0.75
240
0.72
Wire Color
Purpose
Brown
Main / Line (120 to 240VAC)
Blue
Neutral
Green/Yellow
Ground