background image

Version 5: September 2010 

 

 
 

Earth Test Point -

 

located on the rear housing of the Acclaim luminaire; to test 

the earth - place the test probe where indicated, and perform the earth test.

  

 

Acclaim Zoomspot 

Earth test point on the rear of the luminaire. 

 
 
 

Lamps and Lamping Procedure: 

 

Lamp base / socket = G.Y.  9.5 

 

220V 

– 240V 

M38 

        300W, 2000hrs av. life - display lamp 

M40 

        500W, 2000hrs av. life - display lamp 

T/25              500W, 500hrs av. Life 

– theatre lamp 

T/26, T/27    650W, 600hrs av. life - theatre lamp 
CP82    500W, 180hrs av. life 

– studio lamp 3200K 

CP 89  650W, 180hrs av. life - studio lamp 3200K  
 

Disconnect from the mains supply before lamping. Be aware also that the lamp or luminaire may still be hot, 
so exercise the necessary caution to avoid burns. 
Please dispose of any lamps 

as per the manufacturer‟s instructions. 

 

 
Access to the lamp is by the bottom-hinged door, which is fastened with a side clip. Push the clip to release the door. Use 
the  ejector  to  remove  the  failed  lamp.  Align  the  pins  of  the  new  lamp  to  the  correct  holes  (they  are  different  sizes)  and 
push the lamp firmly home. Do not touch the quartz envelope of the lamp with your fingers 

– use the sheath supplied to 

insert the lamp. Close the door and reconnect the luminaire to the power supply. 
 

 

Point luminaire at blank white wall 4-8m away and focus light to narrow angle 

– front lens forward rear lens back. To 

obtain sharp focus adjusts rear lens only. 

 

Adjust lamp peak/flat knob 

– towards back for flattest field and forward for peaked position. Reconnect the luminaire 

to the power supply and bring up on the dimmer. 

 
 

Focusing your Zoomspot:  

 
The variable beam of your Acclaim Zoomspot is altered by adjusting the front and rear lens in relation to one another. The 
front  lens  defines  the  beam  spread;  the  rear,  the  focus  degree  of  softness  or  sharpness  of  the  beam  edge  or  shutters. 
Finger tight pressure is only necessary to lock the lens off in their required positions. 
 
To find the narrow angle of the beam range: 
 

 

18º-34º 

– move front lens to front of luminaire, adjust rear lens to required focus 

 

24º-44º 

– move rear lens back to rear of slot. Move front lens to define beam angle (24°), approximately 95mm 

from front of lens tray 

 
 

Peak/Flat Light Distribution: 

 
The  lamp  position  can  be  altered  to  peak  or  flatten  the  light  output  of 
Zoomspots.  
 
The peak beam gives a central hot spot falling off evenly to the beam edges. 
This  setting  is  useful  for  normal  stage  lighting  purposes  where  beams  are 
overlapped to achieve an even cover.  
 
Flat  adjustment  provides  a  visually  even  light  beam  suitable  for  gobo 
projection.  Take  care  to  move  the  lamp  carefully  as  the  lamp  filament  is 
burning h

ot and at its most vulnerable. Don‟t over tighten the lamp tray knob; 

finger tight pressure is all that is required. 

 

Содержание Selecon Acclaim

Страница 1: ...tirely at your risk Read this manual from cover to cover before attempting installation Do not attempt installation unless you are suitably qualified If you do not understand a point in this manual don t guess Don t take short cuts If in doubt stop Contact Philips Selecon or one of its authorised distributors for advice Don t be afraid to ask for help Table of Contents Important 2 Safety Warnings ...

Страница 2: ...rty Philips Selecon used all due care in preparing this manual However Philips Selecon accepts no liability for errors or omissions Philips Selecon reserves the right to change the specifications of its luminaires or the information in this manual without necessarily giving its customers notice thereof Installation operation and maintenance are entirely at the customer s risk Philips Selecon lumin...

Страница 3: ...t Pass the set screw through the yoke hole from the inside put on a washer then the hook clamp another washer and then tighten the nut If you are not using the set screw washers and nut please dispose of them responsibly To mount on a telescopic stand Reverse the yoke under the luminaire and bolt the stand s spigot onto the set screw Yoke Pivot Adjustment The yoke on the Acclaim range can be posit...

Страница 4: ...4 8m away and focus light to narrow angle front lens forward rear lens back To obtain sharp focus adjusts rear lens only Adjust lamp peak flat knob towards back for flattest field and forward for peaked position Reconnect the luminaire to the power supply and bring up on the dimmer Focusing your Zoomspot The variable beam of your Acclaim Zoomspot is altered by adjusting the front and rear lens in ...

Страница 5: ... 44º Open the tray with the tray hanging down lift up and out to free the hinge Cleaning Reflector wipe with a soft cloth to remove accumulated dust Lens the assembly can be removed out of the luminaire clean with a soft cloth To remove baked on dust use a window cleaner Accessories Suspension Hookclamp Order Code 20HC Adjustable Iris Order Code 15ACIRIS Lens Safety Mesh Order Code 15ACSM 24º 44º ...

Страница 6: ... indirect incidental special or consequential costs or damages including dismantling and re installation costs loss of operations or profits to the maximum extent permitted by law Philips Selecon accepts no liability for personal injury or property damage resulting from failure to heed relevant operating and safety procedures specified by Philips Selecon or imposed by law This is an express warran...

Страница 7: ...Version 5 September 2010 7 ...

Отзывы: