background image

Parent Unit

Remove the battery compartment cover (20) by lifting the cover outward

from the bottom.

Insert the two enclosed AA rechargeable batteries, noting the + and -

configuration inside the battery compartment.

Put the battery compartment cover back in place.

First slide the upperside of the cover into the recesses in the battery
compartment.Then press the underside downwards until it clicks in
position.

Connect the AC power adapter (19) to a mains socket.

Place the Parent Unit inside the charging base (17).

> The red charging light (18) lights up.
> The Parent Unit can be operated now, but you should leave it in the

charging base until the batteries are fully charged (at least 16 hours).
When the batteries are fully charged, the Parent Unit can be taken out
of the charging base and used cordlessly for up to 16 hours.

> When the battery check light (21) lights up red, the battery power is

low. Place the Parent Unit inside the charging base to recharge the
batteries.

> If the rechargeable batteries begin to lose their effectiveness, replace

them with two new rechargeable batteries.

Note: Use rechargeable batteries only! 

Never operate the Parent Unit with other types of batteries!

Disposal of batteries

Dispose of used batteries in an environmentally friendly manner.

Do not mix old and new batteries, or different types of batteries.

Remove Baby Unit batteries if the baby monitor is not to be used for
long periods.

ENGLISH

8

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

SC478_book.qxd  06-07-2004  09:46  Pagina 8

Содержание SBCSC478

Страница 1: ...l 28 Bedienungsanleitung Deutsch 40 Gebruiksaanwijzing Nederlands 52 Istruzioni per l uso Italiano 64 Instruções de uso Português 76 88 Bruksanvisning Svenska 100 Vejledning Dansk 112 Bruksanvisning Norsk 124 Käyttöohje Suomi 136 baby monitor SC478 DECT SBC SC478_book qxd 06 07 2004 09 46 Pagina 1 ...

Страница 2: ...nce Phone 08 25 88 97 89 Greece Phone 00800 3122 1280 Ireland Phone 01 764 0292 Italia Italy Phone 199118899 Nederland Netherlands Phone 0900 8406 Norge Norway Phone 2274 8250 Österreich Austria Phone 0810 001203 Portugal Phone 2416 3033 Schweiz Suisse Svizzera Switzerland Tel 0844 800 544 Suomi Finland puh 09 615 80 250 Sverige Phone 08 598 522 50 UK United Kingdom Phone 0870 9009070 SC478_book q...

Страница 3: ...3 1 3 2 4 5 6 9 0 8 7 A Baby Unit B Parent Unit SC478_book qxd 06 07 2004 09 46 Pagina 3 ...

Страница 4: ...ays out of reach of the baby at least one metre away Never place the Baby Unit inside the baby s bed or playpen Never cover the baby monitor with a towel blanket etc Clean the baby monitor with a damp cloth Never use the baby monitor near water Dispose of used batteries in an environmentally friendly manner Safety precautions Check if the voltage indicated on the type plate of the adapters corresp...

Страница 5: ...ew A Baby Unit 1 Page button pages the Parent Unit in case you need to locate it 2 Night light button ɨ switches on the nightlight 3 DECT SYSTEM LINK light lights orange unit switched on blinks red no connection for more than 30 seconds the system check alarm on the Parent Unit beeps blinks green slowly searching for connection blinks green fast transmitting sound when TALK button pressed lights g...

Страница 6: ...n TALK button pressed lights green connection OK 16 Loudspeaker 17 Charging base 18 Charging light 19 AC power adapter 20 Battery compartment cover 21 Battery check light lights up red when battery power is low 22 Belt clip 23 ON OFF button A switches the Parent Unit On and Off 24 TALK button talks to your baby via the Baby Unit 25 Sound level lights indicate that sound is detected by the Baby Uni...

Страница 7: ...ce Slide the cover upward until it clicks in position Turn the Battery Lock knob to the right for this use a coin The Baby Unit is now ready for battery operated use The Baby Unit operates for a minimum of 25 hours on fresh batteries When the battery check light 10 flashes red the battery power is low The Baby Unit should now still operate for 15 minutes After that you should install new batteries...

Страница 8: ...ase until the batteries are fully charged at least 16 hours When the batteries are fully charged the Parent Unit can be taken out of the charging base and used cordlessly for up to 16 hours When the battery check light 21 lights up red the battery power is low Place the Parent Unit inside the charging base to recharge the batteries If the rechargeable batteries begin to lose their effectiveness re...

Страница 9: ...n 2 Press and hold the A button 5 on the Baby Unit to switch on the Baby Unit 3 Press and hold the A button 23 on the Parent Unit to switch on the Parent Unit All lights light up for 2 seconds and then turn off again The DECT SYSTEM LINK lights 3 and 15 of both units light up orange then start blinking green The units now search for connection The DECT SYSTEM LINK lights 3 and 15 of both units lig...

Страница 10: ... Baby Unit and Parent Unit is established Adjusting microphone sensitivity 1 Press the SENSITIVITY button 14 on the Parent Unit The sound level lights 25 give visual feedback about the current sensitivity level for approximately 2 seconds 2 Use the buttons 13 on the Parent Unit to increase decrease the microphone sensitivity of the Baby Unit The sound level lights 25 on the Parent Unit give visual...

Страница 11: ...The more sound your baby makes the more lights light When no sound is detected all lights will be off If the volume of the Parent Unit is set to Off the Parent Unit will beep as soon as the second sound level light 25 lights red Checking that the units have established a connection Check that the DECT SYSTEM LINK light 15 on the Parent Unit lights continuously green to confirm that the connection ...

Страница 12: ...t Unit will automatically reset to medium volume level and paging alert will sound To stop the paging alert press the Page button again or any button on the Parent Unit Operating range The SBC SC478 baby monitor has an open air operating range of up to 300 metres Walls ceilings large objects and even glass will decrease the operating range Depending on your local circumstances the operating range ...

Страница 13: ...teries do not using only NiMH rechargeable batteries charge Battery polarity misfitted Fit battery in correct polarity position Poor contact between Unit and Clean Charger contact with soft dry cloth Charger No sound Volume on Parent Unit is set too low Increase Parent Unit volume Sensitivity setting on Parent Unit too low Adjust sensitivity level of Parent Unit Units are out of range Move Parent ...

Страница 14: ...ange may decrease to 50 meters Operating temperature 0 C to 40 C Standard Digital Enhanced Cordless Telecommunications DECT Resetting to default factory settings Factory Initialisation mode With this mode both units can be reset to the default factory settings Factory Initialisation can be used if problems occur which can not be solved by following the suggestions in chapter Problem solving Resett...

Страница 15: ...set again Factory default settings are Parent Unit Volume level 1 1 light Baby Unit Volume level 3 3 lights Baby Unit Sensitivity level 5 5 lights Need Help In case you have any questions about the SBC SC478 please contact our helpline for assistance You can find the number in the list on page 2 Before you call please read this manual carefully You will be able to solve most of your problems The m...

Страница 16: ...ur Forhandlerens navn adresse og unterskrift Forhandlerens navn adresse og unterskrift Jälleenmyyjän nimi osoite ja allekirjoitus Nome morada e assinature da loja Date of purchase Date de la vente Verkaufsdatum Aankoopdatum Fecha de compra Date d acquisito Data da adquirição G Inköpsdatum Anskaffelsesdato Kjøpedato Oatopäivä 6 month guarantee on rechargeable batteries 6 mois de garantie sur les pi...

Отзывы: