AC power adapter 230V AC, 50 Hz (two included).
Output voltage 9V DC, 200mAh.
–
Up to 200 meters / 750 feet in open air.
Depending on the surroundings and other disturbing factors
this range may be limited.
Dry materials
Material
Loss of
thickness
range
Wood, plaster, plaster
< 30cm / 12˝
0-10%
cardboard, glass (without
metal or wires, no lead)
Brick, plywood
< 30cm / 12˝
5-35%
Reinforced concrete
< 30cm / 12˝
30-100%
Metal grids, bars
< 1cm / 0.4˝
90-100%
Metal, aluminium sheets
< 1cm / 0.4˝
100%
For wet and moist materials reduction can be as up to 100%.
10 °C - 40 °C
40.665 MHz, 40.680 MHz, 40.695 MHz
EN
Technical specifications
14
Question
Parent unit reacts too
slow/late on baby's cry.
Parent unit reacts too quick
on other ambient sounds.
The link is lost every now and
then, sound interruptions etc.
Frequently asked questions
Answer
Set microphone sensitivity on the baby unit to a higher level
and/or move the baby unit closer to the baby
(keep minimal distance of 1 meter / 3 feet).
Set microphone sensitivity on the baby unit to a lower level
and/or move the baby unit closer to the baby
(keep minimal distance of 1 meter / 3 feet).
You are probably approaching the outer boundaries of the
practical range.Try a different location or reduce the distance
slightly. Please note that it takes about 30 seconds each time
before a new link is established.
Power supply
Operating range
Operating temperature
Transmission frequencies