Ordering accessories

To purchase accessories for this appliance, please 

visit our online shop at 

www.shop.philips.

com/service

. If the online shop is not available in 

your country, go to your Philips dealer or a Philips 

service centre. If you have any difficulties obtaining 

accessories for your appliance, please contact the 

Philips Consumer Care Centre in your country. You 

find its contact details in the worldwide guarantee 

leaflet. 

The following parts are available:

HQ8505 adapter

RQ12 Philips Shaving Unit 

HQ110 Philips Shaving Head Cleaning Spray

HQ200 Philips Cleaning Fluid

RQ111 Beard Styler attachment

shaving heads

We advise you to replace your shaving heads 

every two years. Always replace the shaving unit 

with an original RQ12 Philips Shaving Unit.

Cleaning

Specific types only: use Jet Clean Solution 

(HQ200) for regular cleaning of the shaving heads. 

Environment

Do not throw away the appliances with the 

normal household waste at the end of their life, 

but hand them in at an official collection point for 

recycling. By doing this, you help to preserve the 

environment.

-

-

-

-

-

-

-

-

English

DFU_RQ1295CC他3機種_EN_CS2_A6.indd   61

12.4.19   7:43:08 PM

Содержание RQ1251

Страница 1: ...フ ィ リップス 電動シェーバー 品 番 RQ CC RQ CC RQ CC RQ 取 扱 説 明 書 保証書付 保証書は この取扱説明書の最終 ページについておりますので販売店 で記入を受けてください ...

Страница 2: ...電アダプタ HQ8505 出荷時にLED表示部 分を保護するために シールを貼っています お使いになる前に はがしてください スタイラー コーム ヒゲスタイラー アタッチメン ト RQ111 RQ1285CC RQ1265CC RQ1251CCのみ RQ1265CC RQ1251CC用 専用クリーニング液 フィリップス シェーバーをお買い上げいただき まことにありがとう ございます 長い間ご愛用いただくために ご使用前にこの取扱 説明書をよくお読みのうえ 正しくお使いください また お読みになった後は お使いになる方がいつでも見られる ところに必ず保管してください 商品のご確認 商品をご確認ください 改良の為 仕様を予告なく変更することがあります ...

Страница 3: ...なります 該当する品番を下記の一覧よりお選びいただき 付属品をご確認ください RQ1285CC RQ1265CC RQ1251CC RQ1251 保護キャ ップ クリーニング ブラシ ソフ トケース 充電スタン ド 充電アダプタ HQ8505 ヒゲスタイラーアタッチ メント RQ111 ー ー 洗浄充電器 RQ1008 ー ー ー 洗浄充電器 RQ1007 ー ー 専用クリーニング液 ー 付属品 品番 品番末尾にCCの付く製品は 洗浄充電器付きモデルです ...

Страница 4: ...でき ません 一度通電しホルダーの位置を上げてからシェーバーをセッ トしてく ださい クリーニング液に関して フィリップスの専用クリーニング液であれば どのタイプの製品もご使用い ただけます 初期充電時は 満充電の表示は 60分 ですが ご使用状況 1回あたりの 使用時間 ヒゲの濃さ ヒゲの長さ 肌への製品のあて方 による自動学習機 能が働き その状況で継続使用された場合の使用可能時間を本体に表示 します ご使用状況が変わると表示される数字も変化しますが これは故障 ではありません 洗浄充電器付きモデルお買い上げのお客様へ RQ1285CCお買い上げのお客様へ ...

Страница 5: ... 9 11 充電の仕方 12 シェービングの仕方 13 15 トリマーの使い方 16 ヒゲスタイラーアタッチメン トの使い方 17 18 お手入れ方法 19 25 携帯の仕方 シェービングユニッ トの交換 26 シェーバーを廃棄するとき 27 故障かな と思ったら 28 30 Guidance in English 31 67 保証とアフターサービス 68 仕様 お客様情報センター 69 無料修理規定 70 保証書 最終ページ は じ め に ご 使 用 方 法 困 っ た と き 英 文 解 説 保 証 ...

Страница 6: ...ない 感 電やケガをすることがあります 充電アダプタが傷んだり コンセン ト の差込みが緩いときは使用しない 感電 ショー ト 発火の原因になります 充電アダプタ 洗浄充電器および充 電スタン ドを水につけたり 水をか けたりしない 故障や ショート 感 電の原因になります 充電アダプタを傷付けたり 電源 コー ドを無理に曲げたり 引っ張った り ねじったり たばねたり 重い物を 載せたり 挟み込んだり 加工したり しない 電源コードが破損し 火災 感電の原因となります 乳幼児の手の届くところに本製品を 置かないでください 充電アダプタには変圧器が内蔵さ れています 充電アダプタを切り離 して別のプラグに接続するのは危険 ですのでおやめください 絵表示の例 記号は してはいけない 禁止 を示します 図の中や近くに 具体的な禁止内容 左図の場合は分解禁止 を示します 記号は 必ずしていただく...

Страница 7: ...外刃は 薄く仕上げてありますので 刃部を強く押さえたり 硬いものに当てないよう ていねいに扱ってください 注 意 充電アダプタの電源プラグを抜くと きは 電源コード部を持たずに必ず 先端の電源プラグ部を持って引き 抜く 感電やショートして発火する ことがあります 充電時または洗浄充電器の使用時 以外は 充電アダプタをコンセン ト から抜く ケガややけど 絶縁劣化に よる感電 漏電 火災の原因となり ます 刃は強く押さえない 破損して皮膚 を傷つけることがあります 刃が破損または故障した場合は 本 製品を使用しないでください ケガ の原因になります 交換の際には必 ずフィリップス社製の同型部品と お取り替えください 電源コネクタ受部にピンやごみを 付着させない 感電 ショート 発火 の原因になります 12 シェーバー本体は防水加工をしておりますが 水や液体の中に浸けないでください 14 洗浄...

Страница 8: ... シェービングユニッ ト 保護キャ ップ LED表示 ON OFF スイッチ 本体 トリマー トリマー スライ ドノブ シェービングユニッ ト RQ12 内刃 外刃 保持板 ヒゲスタイラー アタッチメン ト RQ111 スタイラー コーム 長さ調節 レバー RQ1285CC RQ1265CCのみ 各部の名称 ...

Страница 9: ...ーバーをセッ トしてください 洗浄ON OFF スイッチ モード選択 スイッチ RQ1008のみ LED表示 クリーニング室 シェーバーホルダー 洗浄充電器 ジェ ッ トクリーン RQ1008 洗浄充電器 ジェッ トクリーン RQ1007 RQ1265CC RQ1251CC用 電源コネクタ受部 ソフ トケース クリーニング ブラシ 電源 コネクタ部 電源 プラグ部 充電アダプタ HQ8505 充電スタン ド 電源コネクタ 受部 RQ1285CC用 専用クリーニング液 RQ1285CC RQ1265CC RQ1251CCのみ ...

Страница 10: ...分に達すると白色の点滅になります 洗浄充電器で充電の場合は MINUTES LEFT の表示が白色に点滅します 充電完了表示 充電が完了すると 使用可能時間 分 の表示が点灯し続けます 満充電後 約30分経過すると充電表示ランプが消えます 満充電後に本体を再び充電スタン ドに置くと 充電表示ランプが点灯しますが 故障ではありません 初期充電時は 満充電の表示は 60分 ですが ご使用状況 1回あたりの使用 時間 ヒゲの濃さ ヒゲの長さ 肌への製品のあて方 による自動学習機能が働 き その状況で継続使用された場合の使用可能時間を表示しています ご使用 状況が変わると表示される数字も変化します 充電催促表示 充電残量が少なくなると MINUTES LEFT の表示が赤色に点 滅します スイッチを切ると 使用可能時間 分 の表示が数秒間点滅後 消灯する と電子音が鳴ります クリーニング表示 3分...

Страница 11: ...点灯しますが 故障ではありません 充電催促表示 充電残量が少なくなると 一番下の充電表示ランプがオレンジ色 に点滅し始めます スイッチを切ると 一番下の充電表示ランプが数秒間オレン ジ色に点滅後 消灯します クリーニング表示 3分以上使用し OFF にすると クリーニングをうながすため に蛇口マークが点滅します 表示されるタイミングは使用時間 状況により異なり ます お手入れ方法 P19 25 をご参照ください シェービングユニッ ト交換表示 シェービングユニッ トの交換マークが点滅する と 交換時期です シェービングユニッ トを交換してください P26参照 この表示 は約2年間 1日3分 使用すると自動的に表示されます ブロック表示 刃に長いヒゲがからまっていたり刃が破損していると クリー ニング表示と マーク 刃の点検表示が同時に点滅し スイッチをONにする ことができません シェービ...

Страница 12: ...までの時間は約2時間です モー ド選択スイッチはありません 洗浄時間や乾燥時間は前後することがあります 洗浄中は洗浄ランプが点滅します 洗浄が終わると ドライランプが点滅します シェーバーの乾燥中は ドライランプが点滅します クリーニング液が入っていない場合や量が少ない場 合 または専用クリーニング液以外をご使用の場合 クリーニング液補充ランプが点滅し クリーニング液 の補充を促します 専用クリーニング液以外をご使用の場合 クリーニング室に ある液体を全て捨ててから 新しいクリーニング液を入れて ください 洗浄ランプ ドライランプ クリーニング液補充ランプ 洗浄から乾燥終了までの時間 AUTO 約2時間 ECO 約1時間 INTENSIVE 約2時間半 INTENSIVEモー ドでは洗浄効果を高めるため 洗浄中に約30分動作が止まります ECO AUTOモー ドでは シェーバーの使用状況に...

Страница 13: ...チッと音がするまで押 し込み 図 シェーバー ホルダーにセッ トします 2 充電アダプタの電源コネクタ部を洗浄 充電器の電源コネクタ受部につない で ご家庭のコンセン トに電源プラグ部 を差し込みます 洗浄充電器で充電する場合 RQ1285CC RQ1265CC RQ1251CCのみ 充電池 の寿命 満充電後の使用時間が3分の2程度になったら充電池の交換時期です お買い求めの販売店へ充電池の交換を依頼してください 有料になります 充電スタン ドで充電する場合 4 シェーバーを充電スタン ド に置きます 充電中は充電 表示ランプが点滅します 充電表示については P9 10をご参照ください 2 充電スタン ドを 開きます 1 充電アダプタの電源コネクタ 部を充電スタン ドの電源コネ クタ受部につなぎます 3 ご家庭のコンセン トに電源プラグ部を 差し込みます 1 2 この商品は通常約1時間充電...

Страница 14: ...2 刃を肌に軽く押しあて 円を描くように 動かしながら剃ります 肌が乾いた状態でのシェービングの 仕方です シェーバー本体は防水加工をしており 浴室でも使用できますが 水や 液体の中に浸けないでください 故障の原因となります 警告 モーターの始動時 微弱の振動がシェーバー本体に伝わりますが 問題はありません ほこりなどで肌が汚れている場合 ふきとってからご使用ください ご使用の前に外刃の破れや変形がないか確認してください 外刃に破れや変形があると肌を傷つける原因になります ヒゲ剃り以外の目的 頭髪など には 使用しないでください ...

Страница 15: ... ほお 肌を伸ばし ヒゲを立たせるように小さく回 しながら剃ります あごの裏側 刃を肌に軽くあて 図のようにあごを上げて 回転させながら剃ります ほおの奥から首筋 片方の手で肌を後ろに引っ張り小さく回しな がら剃ります 鼻の下 鼻の下を伸ばし 小さく回しながら剃ります フィリップスのシェーバーを初めてお使いの方は 剃り方に慣れるまで2 3週間かかることが あります 肌に強く押しつけるのではなく 軽く押しあてるのがコツです ...

Страница 16: ...くよう に動かしながら剃ります シェービングフォームやシェービング ジェルにより 鏡を見た時に剃った部分 を確認しやすくなります 途中 よりなめらかにシェービングするため に シェービングヘッ ドを水で濡らすと効果 的です 5 シェービング後はスイッチを押し 電源 をOFFにします 6 シェーバーをきれいに洗います P22 お手入れ方法 洗浄充電器を使う前に水洗いによるお手入 れ P22 を行うと クリーニング液が長もち します シェービングフォームやシェービン グジェルがしっかりと洗い流されているかを 確認してください シェーバー本体は防水加工をしており 浴室でも使用できますが 水や 液体の中に浸けないでください 故障の原因となります 警告 モーターの始動時 微弱の振動がシェーバー本体に伝わりますが 問題はありません ご使用の前に外刃の破れや変形がないか確認してください 外刃に破れや変形...

Страница 17: ...と トリマーが出ます スイッチを ONにすると トリマー先端の刃が往復 してカッ トします 3 カチッ 1 2 4 ご使用ごとに 必ずスイッチをOFFにし てからクリーニングブラシの短い方の 毛で刃の部分を軽く掃除してください トリマーの切れ味を保つため 使用後は必ず ぬるま湯ですすぎ洗いをしてください P23 トリマーのお手入れ方法 5 シェービングユニッ トのつけ方 トリマーを戻し シェービングユニッ ト の突起部 図 をシェーバー上部の 溝 図 に合わせ カチッと音がする まで押し込み 図 本体に取りつけ ます 注意 あまり押し当て過ぎると肌を傷 めますのでご注意ください スライドノブ シェービングユニッ ト は 回さずにまっすぐ 引き抜いてください トリマーはヘアーライン もみあげ ヒゲなどを整えるのに便利です ...

Страница 18: ...ずします 2 ヒゲスタイラーアタッチメン トの突起部 図 をシェーバー上部の溝 図 に合わせ カチッと音がするまで押し込 み 図 本体に取り付けます シェービングユニッ トは回さ ずにまっすぐ引き抜いてく ださい 1 スタイラーコームをヒゲス タイラーアタッチメン トの 両側にある溝にそって カ チッと音がするまでスライ ドさせて取り付けます ヒゲスタイラーアタッチメン トにコームを取り付けて カッ トの仕上がりが均一になるようにした り 違った長さでそろえたりすることができます スタイラーコームを使用し カッ ト後の仕上がり の長さを1 5mmにそろえることができます 1 2 3 カチッ 3 電源スイッチをONに します 2 長さ調節レバー 図 を押し 右左に 動かして 図 好みの長さに調節し ます 4 コームの先を肌に密着させヒゲの流れ に逆らうように動かします カチッ ...

Страница 19: ...ゲ もみあげの手入れをしたり 輪郭を整えたりすることができます 1 スタイラーコーム をヒゲスタイラー アタッチメン トから はずします 3 ヒゲの流れに逆らうように動かします 2 電源スイッチをONにします ヒゲスタイル 下記のようなさまざまなヒゲスタイルをお楽しみください ちょいワル無精ヒゲ フルフェイス ピラミッ ドヒゲ ドーナツヒゲ コームの中心をつ かんで ヒゲスタ イラーアタッチメ ントからはずしま す コームの両側 を持ってはずさな いでください コームなしの仕上がりの 長さは0 5mmです ...

Страница 20: ...洗いのお手入れもでき ますが 洗浄充電器によるお手入れもできま す 水洗いの場合は P22をご参照ください 洗浄充電器を使ったお手入れ方法 RQ1285CC RQ1265CC RQ1251CCのみ 洗浄充電器の準備 クリーニング液の入れ方 クリーニング液を上の ラインより多く注がな いでください こぼれ る原因となります 1 1 洗浄充電器を水平な場所に 設置します 洗浄充電器両サ イドにあるクリーニング室の 着脱ボタンを同時に押して 図 洗浄充電器本体を持 ち上げクリーニング室を 外します 図 2 カチッ 出荷時はシェーバーホルダーが下がっているため シェーバーをセッ トできません 一度通電しホルダーの 位置を上げてからシェーバーをセッ トしてください シェーバーをご使用の都度 洗浄充電器で洗浄 乾燥 充電をしていただいても シェーバー本体や 洗浄充電器に問題はありません ご使用のたびに...

Страница 21: ... P19を参照し ク リーニング液をウェーブマー クが見えなくなるまで注いで ください 2 洗浄を開始すると 洗浄ランプが点 滅し シェーバーをセッ トした シェーバーホルダーが下 降しクリーニング室内で シェービングユニッ トの 洗浄を行います 3 ドライランプが点滅し シェーバーを 乾燥させます 乾燥が終了すると シェーバーの充電表示が現れ 充電を 再開します ジェッ トクリーンシステムでは洗浄はできますが 消毒はできません 衛生上 シェーバーを他の人と共有しないでください 洗浄中に電源プラグが抜けて洗浄が中断された場合 シェーバーホルダーはその ままの位置で止まります 再び電源プラグを接続するとシェーバーホルダーが元 の位置に戻ります 洗浄するには 再び洗浄ON OFFスイッチを押してください 洗浄中は 洗浄充電器を動かしたり クリーニング室を取り外さないでください シェービングユニ...

Страница 22: ...します 図 2 クリーニング室にあるクリーニング液 とヒゲクズを洗い流してください クリーニング室は2週間に一度お手入れしてください 3 クリーニング室をきれいに水洗いし て 乾いた布で水分を拭き取ってくだ さい 4 洗浄充電器を水平な場所に設置しま す クリーニング液をクリーニング室 のウェーブマークが見えなくなるまで 約150ml 注ぎます クリーニング室 の上に洗浄充電器をセッ トします カチッ と音がしてセッ トされたことを確認して ください クリーニング室は食器洗浄乾燥機で洗わないでください 変形 故障する 原因となります 洗浄充電器本体のお手入れは 水で濡らした布を絞ってお使いください 注意 カチッ ...

Страница 23: ...る場合がありますが これは正常な状態です 電子部品 はすべてシェーバー内部の密閉された部分に内蔵されているので 危険はありません お手入れの際は スイッチをOFFにしてから外刃を開けて水洗いしてください シェービングユニッ トは水洗いできますが 本体は水中に浸けないでください シェービングユニッ トを乾燥させる時に タオルやティ ッシュペーパーを使 用しないでください 刃を傷める場合があります 注意 2 外刃を一つずつ開けてください 3 シェービングユニッ トにたまったヒゲク ズをぬるま湯または水で約30秒洗い 流します 5 細かい部分は シェービングユニッ トが 乾いてからクリーニングブラシで掃除 してください より細かいお手入れ方法は P24をご参照く ださい 水洗いの後は充分乾燥させてから外刃を閉めて ください 乾燥が不充分な場合 臭いが出る原因 となります 水洗いによるお手入れ方法...

Страница 24: ...ら トリ マーを戻します トリマーにヒゲクズが 残った場合には クリーニングブラシで 取り除いてください トリマーのお手入れ方法 ヒゲスタイラーアタッチメン トのお手入れ方法 RQ1285CC RQ1265CCのみ ヒゲスタイラーアタッチメン トは 使用後必ずお手入れしてください 1 コームをヒゲスタ イラーアタッチメン トからはずします 2 ヒゲスタイラーアタッチメン トとコーム を別々にぬるま湯で洗います 付属のクリーニングブラシを使って掃除する こともできます コームの中心をつ かんで ヒゲスタ イラーアタッチメ ントからはずしま す コームの両側 を持ってはずさな いでください ...

Страница 25: ...の状態が元通りにな るまで数週間かかる場合があります 刃の取り外し方 1 シェービングユニッ トを本体からはず します シェービングユニッ トは 回さずにまっすぐ 引き抜いてください 2 外刃を開けます 外刃と内刃の組み合 わせが変わるのを防ぐために 複数の 刃を同時に分解せず 1つずつお手入 れしてください 5 取りはずした内刃を1つずつぬるま湯 40 前後 に浸して 皮脂やヒゲクズ をクリーニングブラシで掃除します 6 外刃の内側をクリーニングブラシで 掃除します 4 内刃を取り出します 3 保持板のツメ部分 図 を押し 保持 板 図 を開けます 1 2 ...

Страница 26: ...25 刃の取り付け方 1 内刃のカッター部分を下に向けて 外刃に戻します 2 保持板を戻し 保持板のツメ部分をカチッと音がするまで押し込み 外刃を閉じます 3 シェービングユニッ トの突起部 図 をシェーバー上部の溝 図 に合わせ カチッと 音がするまで押し込み 図 本体に取り付けます 必ず刃は 下向きに カチッ 3 カチッ 1 2 ...

Страница 27: ...ェービン グユニッ トの交換 3をご参照ください な お お客様ご自身でリセッ トされない場合 は 合計9回のご使用の間 この表示が続 き 9回目のご使用が終わると自動的にリ セッ トされます シェービングユニッ ト交換 表示についてはP9 10をご参照ください 1 シェー バ ー 本 体 から シェービングユニッ ト をはずします シェービングユニッ トは 回さずにまっすぐ引き抜 いてください 2 新しいシェービングユニッ トの突起部 図 をシェーバー上部の溝 図 に合わ せ カチッと音がするまで押し込み 図 本体に取り付けます MINUTES LEFT MINUTES LEFT シェービング ユニッ トの交換 シェービングユニッ トは約2年 1日3分 ご使用の場合 での交換が目安です 専用のシェービングユニット 品番 RQ12 と交換してください 3 カチッ 1 2 3 スイッチを押し...

Страница 28: ...協力店 にお持ちください スイッチをONにして 完全に動作しなくなるまで充電池を放電させてから 行ってください 1 シェービングユニッ トをはずし 本体下 部の穴に ドライバーをこ じ入れて ユニッ トカバーをはずします 充電池を取り外した後は 通電しないでください 製品を廃棄するとき以外は 絶対に本体を分解しないでください 本体内部の金具は鋭いので ご注意ください 注意 お客様による充電池の 修理交換はできません 2 フロン トカバーとモーターユニッ ト 灰 色の部分 を固定している2つの金具を はずして フロン トカバーを取りはずし ます 3 モーターユニッ トにある左右3つずつ 計6つのツメをはずし カバーを開け ます 4 充電池ホルダーを持ち上げて工具でワ イヤーを切断し 取り出します ...

Страница 29: ...交換をしてください 充電しても使用時間が極端に短い シェーバーが完全に止まるまで作動させてからもう一度充電してください それでも改善されないときは 充電池の寿命です P12 充電池の寿命 の項をお読みください だんだん切れ味が悪くなった シェービングユニット部が汚れていませんか シェービングユニット部が損傷または摩耗していませんか 損傷または摩耗しているときは シェービングユニットを交換してください シェービングユニット品番 RQ12 シェービングユニットに長いヒゲがからまっていませんか P24 25 分解掃除の仕方 の項をお読みください 専用クリーニング液が汚れていませんか P19 お手入れ方法 をお読みになり 新しいクリーニング液と入れ替えてください シェーバー本体のモーターは回転しているが 内刃が回転しない 外刃にキズ ヘコミはありませんか シェービングユニットを交換してください シ...

Страница 30: ... 充電スタンドや洗浄充電器で充電しても 満充電にならない シェーバー本体が正しくセットされていますか しっかりと固定されるまで シェーバーを押し込んでください 洗浄充電器を使用してもシェーバーがあまりきれいにならない 専用クリーニング液が古くなっていませんか 専用クリーニング液を使用していますか P19 お手入れ方法 の項をお読みください 洗浄充電器の洗浄ON OFFボタンを押しても作動しない 充電アダプタの電源プラグ部はコンセントにきちんと差し込まれていますか 洗浄充電器のシェーバーホルダーにシェーバーが正しくセットされていますか 専用クリーニング液がウェーブマークが見えなくなるまで入っていますか P19 お手入れ方法 の項をお読みください 洗浄充電器のシェーバーホルダーにある金属製の本体との接点が汚れていませんか ご家庭のコンセントから電源プラグ部を必ず抜き取った上で 乾いた布で接点の...

Страница 31: ... の項をお読みください これは故障ではありません 本製品はお客様のご使用状況 1回あたりの使用時間 ヒゲの濃さ ヒゲの長さ 肌への製 品のあて方 により本体にかかる負荷を自動的に学習し その状況で継続使用された場合の 使用可能時間を表示しています ご使用状況が変わると表示される数字も変化します 満充電後の使用時間が40分程度になったら充電池の交換時期です お買い求めの販売店へ充電池 の交換を依頼してください 有料になります 1時間充電 満充電 しても 使用可能時間表示が60分より多い 少ない RQ1285CCのみ ...

Страница 32: ...31 RQ129x RQ128x RQ127x RQ126x RQ125x English ...

Страница 33: ...32 A C D 1 2 3 4 5 8 7 6 14 13 9 10 11 12 B E F G H ...

Страница 34: ...Shaver on off button 3 Protection cap 4 RQ12 Shaving unit 5 Trimmer 6 Trimmer on off slide B RQ111 Beard Styler attachment RQ1295 RQ1285 RQ1275 RQ1265 1 Hair length selector 2 Comb of Beard Styler attachment C Foldable charger D Jet Clean System RQ1296CC RQ1295CC RQ1290CC RQ1286CC RQ1285CC RQ1280CC RQ1275CC RQ1265CC RQ1260CC RQ1252CC RQ1251CC only 1 Cleaning chamber empty symbol 2 Cleaning symbol ...

Страница 35: ...a transformer Do not cut off the adapter to replace it with another plug as this causes a hazardous situation These appliances are not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliances by a person responsible for their safety ...

Страница 36: ...ories if they are damaged If the adapter or any of the other accessories is damaged always have it replaced with one of the original type in order to avoid a hazard Water may leak from the socket at the bottom of the shaver when you rinse it This is normal and not dangerous because all electronics are enclosed in a sealed power unit inside the shaver Beard Styler attachment specific types only Cau...

Страница 37: ...ot dishwasher proof When the Jet Clean System is ready for use do not move it to prevent leakage of cleaning fluid Compliance with standards This shaver complies with the internationally approved safety regulations and can be safely used in the bath or shower and cleaned under the tap These Philips appliances comply with all standards regarding electromagnetic fields EMF If handled properly and ac...

Страница 38: ...s The shaving minutes increase until the shaver is fully charged Quick charge When the shaver contains enough energy for one shave the display shows 5 minutes in red RQ127x RQ126x RQ125x Note The displays of the various shaver types look different but the charging lights work in the same way MINUTES LEFT MINUTES LEFT MINUTES LEFT MINUTES LEFT MINUTES LEFT MINUTES LEFT MINUTES LEFT MINUTES LEFT Eng...

Страница 39: ...gy consumption and converts the remaining battery capacity into shaving minutes The energy consumption and therefore the remaining number of shaving minutes depend on your skin and beard type and your shaving behaviour e g the use of shaving gel If the number of shaving minutes of the fully charged shaver is less than 60 minutes this is completely normal and does not mean that the battery capacity...

Страница 40: ... empty when there are only 5 or fewer shaving minutes left the bottom charging light flashes orange When you switch off the shaver the bottom charging light continues to flash orange for a few seconds Remaining battery capacity RQ129x RQ128x The remaining battery capacity is indicated by the number of shaving minutes shown on the display RQ127x RQ126x RQ125x Note The displays of the various shaver...

Страница 41: ...eplace the shaving unit the appliance is equipped with a replacement reminder which is activated automatically after approx two years The replacement reminder is repeated at 9 successive shaves specific types only or until you reset the shaver specific types only Travel lock RQ128x RQ127x RQ126x RQ125x only You can lock the shaver when you are going to travel The travel lock prevents the shaver fr...

Страница 42: ...er or Jet Clean System the travel lock is automatically deactivated Power saving mode RQ129x only The appliance is equipped with an automatic power saving mode When the shaver enters the power saving mode the light in the on off button goes out to save energy When the appliance is switched off but detects movement for 5 minutes for instance when you are travelling with the shaver in your suitcase ...

Страница 43: ...arging takes approx 1 hour RQ129x RQ128x RQ127x RQ126x A fully charged shaver has a shaving time of up to 60 minutes or 20 days Note RQ129x RQ128x When the battery is fully charged the display shows the actual remaining shaving minutes see section Battery fully charged in chapter The display RQ125x A fully charged shaver has a shaving time of up to 50 minutes or 16 days Charge the shaver before yo...

Страница 44: ...g in the Jet Clean System specific types only 1 Put the small plug in the Jet Clean System 2 Put the adapter in the wall socket 3 Hold the shaver upside down above the holder with the back of the shaver pointing towards the holder Note The shaver cannot be placed in the Jet Clean System when the protection cap is on the shaving unit Note RQ129x only when you turn the shaver upside down the minutes...

Страница 45: ...44 turned upside down so you can still see to what level the battery is charged English ...

Страница 46: ...ve regularly at least 3 times a week for a period of 3 weeks to allow your skin to adapt to the new shaver During this period use your new electric shaver exclusively and do not use other shaving methods If you use different shaving methods it is more difficult for your skin to adapt to the new shaving system 1 Press the on off button once to switch on the shaver The display lights up for a few se...

Страница 47: ...e shaver 5 Move the shaving heads over your skin in circular movements Note Rinse the shaver under the tap regularly to ensure that it continues to glide smoothly over your skin 6 Dry your face and thoroughly clean the shaver after use see chapter Cleaning and maintenance Note Make sure you rinse all foam or shaving gel off the shaver Trimming You can use the trimmer to groom your sideburns and mo...

Страница 48: ...r 1 Then press down the shaving unit 2 to attach it to the shaver click Using the Beard Styler attachment specific types only 1 Make sure the shaver is switched off 2 Pull the shaving unit straight off the shaver Note Do not twist the shaving unit while you pull it off the shaver 3 Insert the lug of the Beard Styler attachment into the slot in the top of the shaver 1 Then press down the beard styl...

Страница 49: ...48 setting but also at different length settings The hair length settings on the Beard Styler attachment correspond to the remaining hair length after cutting and range from 1 to 5mm English ...

Страница 50: ...ft or right 2 to select the desired hair length setting 3 Press the on off button on the shaver to switch it on 4 You can now start styling your beard Using the Beard Styler attachment without comb You can use the Beard Styler attachment without the comb to contour your beard moustache or sideburns 1 Pull the comb off the Beard Styler attachment 2 1 2 1 English ...

Страница 51: ...Do not pull at the sides of the comb 2 Press the on off button to switch on the shaver 3 You can now start contouring your beard moustache sideburns or neckline Beard styles Below you find some examples of beard styles you can create A stubble look A full beard A moustache English ...

Страница 52: ...u can also rinse the shaver under the tap or clean it with the cleaning brush supplied Be careful with hot water Always check if the water is not too hot to prevent your hands from getting burnt Clean the shaver after every shave for optimal shaving performance You can clean the outside of the shaver with a damp cloth Regular cleaning guarantees better shaving performance Cleaning the shaving unit...

Страница 53: ...ith the cleaning brush supplied Be careful with hot water Always check if the water is not too hot to prevent your hands from getting burnt 4 Carefully shake off excess water and leave the shaving heads open to let the shaving unit dry completely Never dry the shaving unit with a towel or tissue as this may damage the shaving heads Cleaning the shaving unit in the Jet Clean System specific types o...

Страница 54: ...em for use Fill the cleaning chamber before first use 1 Put the small plug in the Jet Clean System 2 Put the adapter in the wall socket The holder automatically moves to the highest position 3 Simultaneously press the release buttons on both sides of the cleaning chamber 1 Then lift the Jet Clean System off the cleaning chamber 2 The cleaning chamber remains behind 4 Unscrew the cap from the bottl...

Страница 55: ...8 Press the up down button to select a cleaning program 4 Press the on off button on the Jet Clean System to start the cleaning program The shaver display stops showing the charging indication The cleaning light starts to flash and the shaver is automatically lowered into the cleaning fluid The cleaning light flashes throughout the cleaning program which takes a few minutes Note RQ1007 The cleanin...

Страница 56: ...eaning or drying light stops flashing and the holder moves to the highest position Note If you remove the adapter from the wall socket during the cleaning program the program aborts The holder remains in its current position When you put the adapter back into the wall socket the holder moves to the highest position When the cleaning fluid drops below the minimum level the cleaning chamber empty sy...

Страница 57: ...g chamber You can simply pour the cleaning fluid down the sink 3 Rinse the cleaning chamber under the tap The cleaning chamber is not dishwasher proof 4 Fill the cleaning chamber with HQ200 cleaning fluid to a level between the two lines 5 Place the Jet Clean System back onto the cleaning chamber Make sure the release buttons click back into place Extra thorough cleaning method Make sure the appli...

Страница 58: ...r release tab 1 until the retainer opens 2 Note Do not clean more than one cutter and shaving guard at a time since they are all matching sets If you accidentally put a cutter in the wrong shaving guard it may take several weeks before optimal shaving performance is restored 4 Remove the cutter from the shaving guard 5 Clean the cutter with the cleaning brush supplied 1 2 1 2 English ...

Страница 59: ...down the retainer over the cutter 9 Close the shaving heads 10 Insert the lug of the shaving unit into the slot in the top of the shaver 1 Then press the shaving unit downwards 2 to attach it to the shaver click Cleaning the trimmer Clean the trimmer every time you have used it 1 Slide the trimmer slide forwards to slide out the trimmer 2 1 2 1 English ...

Страница 60: ...ler attachment every time you have used it 1 Pull the comb off the Beard Styler attachment 2 Rinse the Beard Styler attachment and the comb separately under a hot tap for some time Note You can also clean the Beard Styler attachment and the comb with the cleaning brush supplied 3 Lubricate the trimmer teeth with a drop of sewing machine oil every six months Storage 1 Slide the protection cap onto ...

Страница 61: ...the new RQ12 shaving unit into the slot in the top of the shaver 1 Then press down the shaving unit 2 to attach it to the shaver click 4 RQ128x RQ127x RQ126x RQ125x To reset the shaver press and hold the on off button for approx 10 seconds Note If you do not reset the shaver at the first replacement reminder it continues to beep specific types only and show the shaving unit symbol at 8 more shaves...

Страница 62: ...lowing parts are available HQ8505 adapter RQ12 Philips Shaving Unit HQ110 Philips Shaving Head Cleaning Spray HQ200 Philips Cleaning Fluid RQ111 Beard Styler attachment Shaving heads We advise you to replace your shaving heads every two years Always replace the shaving unit with an original RQ12 Philips Shaving Unit Cleaning Specific types only use Jet Clean Solution HQ200 for regular cleaning of ...

Страница 63: ...le battery when you discard the shaver Make sure the battery is completely empty when you remove it Be careful the battery strips are sharp 1 Remove the back panel of the shaver with a screwdriver 2 Remove the rechargeable battery Guarantee and service If you need service or information or if you have a problem please visit the Philips website at www philips com support or contact the Philips Cons...

Страница 64: ...e chapter Replacement Long hairs obstruct the shaving heads Clean the shaving heads by following the steps of the extra thorough cleaning method see chapter Cleaning and maintenance Specific types only The Jet Clean System has not cleaned the shaver properly because the cleaning fluid in the cleaning chamber is soiled or the cleaning fluid level is too low Clean the shaver thoroughly before you co...

Страница 65: ...see chapters Cleaning and maintenance and Replacement The temperature of the shaver is too high In this case the shaver does not work and the exclamation mark on the display flashes Switch off the shaver and let it cool down As soon as the temperature of the shaver has dropped sufficiently you can switch on the shaver again Specific types only The shaver is not entirely clean after I clean it in t...

Страница 66: ...cleaning fluid Only use HQ200 Philips Cleaning Fluid The Jet Clean System does not work when I press the on off button The Jet Clean System is not connected to the mains Put the small plug in the Jet Clean System and put the adapter in the wall socket You have not placed the shaver in the Jet Clean System properly so there is no electrical connection between the Jet Clean System and the shaver Pre...

Страница 67: ...use of shaving gel If the number of shaving minutes of the fully charged shaver is less than 60 minutes this is completely normal and does not mean that the battery capacity of the shaver has diminished RQ1008 The operating time of the Jet Clean System is suddenly shorter or longer than it used to be You have selected another cleaning program The Jet Clean System has three cleaning programs the ec...

Страница 68: ...67 ...

Страница 69: ...中は 製品に保証書を添えてお買い上げの販売店にご持参ください 保証書の記載内容により無料修理いたします 保証期間が過ぎているときは 修理によって商品の機能が維持できる場合は 補修用性能部品の保有期間内であれば ご希望により有料で修理させていただきます 海外での本製品の保証及びアフターサービスについて 本製品の保証は海外においても有効です 同シリーズ製品の取り扱いがある国に限ります 日本国以外のフィリ ップスサービス部門においても保証期間内及び保証期間の経過後の アフターサービスを受けることができますが この場合多少日数を要することもあります 海外にてアフターサービスを受けられる場合は 現地のフィ リ ップスサービス部門に お問い合わせください 尚 お困りの点がございましたら下記までご連絡ください Philips Consumer Lifestyle Service Department P...

Страница 70: ...ナビダイヤル 全国共通番号 修理に関するお問い合わせ 小泉成器修理センター 0 0 0 ナビダイヤル 全国共通番号 部品に関するお問い合わせ 小泉成器部品センター 0 0 0 ナビダイヤル 全国共通番号 0 0 受付時間 平日9 00 17 30 土 日 祝日 夏期休暇 年末年始を除く 小泉成器東日本修理センター TEL 048 718 3340 344 0127 埼玉県春日部市水角1190 小泉成器西日本修理センター TEL 06 6613 3145 559 0033 大阪市住之江区南港中1丁目3番98号 ナビダイヤルにかからない時は ホームページアドレス http www philips co jp 品 番 RQ1285CC RQ1265CC RQ1251CC RQ1251 洗浄充電器品番 RQ1008 RQ1007 電 源 方 式 充電式 専用充電アダプタ使用 消 費 電 力 1 5...

Страница 71: ...地変 公害や異常電圧による故障及び損傷 4 一般家庭以外 例えば 業務用の長時間使用 に使用された場合の故障及び損傷 5 保証書の提示がない場合 6 保証書にお買い上げ年月日 お客様名 販売店名の記入のない場合 或は字句を書き 換えられた場合 保証書は 本書に明示した条件のもとにおいて無料修理をお約束するもの です 従って保証書を発行している者 保証責任者 及びそれ以外の事業者 に対するお客様の法律上の権利を制限するものではありません 保証期間経過後の修理についてご不明の場合は お買い上げの販売店または 小泉成器修理センターにお問い合わせください 保証期間経過後の修理 補修用性能部品の保有期間について詳しくは取扱 説明書の保証とアフターサービスの項目をご覧ください お客様にご記入いただいた個人情報 保証書の控え は保証期間内のサービス 活動及びその後の安全点検活動のために利用させていただく...

Страница 72: ...証書は再発行しませんので 大切に保管してください ご販売店様へ この保証書はお客様へのアフターサービスの実施と責任を明確にする ものです 贈答品 記念品の場合も含めて必ず記入捺印してお客様にお渡しください 修理に関するお問い合わせ 製品に関するお問い合わせ 部品に関するお問い合わせ ナビダイヤルにかからない時は TEL 06 6261 8230 FAX 06 6268 1432 フィ リ ップスコンシューマーライフスタイル事業部 日本販売総代理店 小泉成器株式会社 541 0051 大阪市中央区備後町3 3 7 ナビダイヤルにかからない時は TEL 06 6613 3211 559 0033 大阪市住之江区南港中1丁目3番98号 ナビダイヤルにかからない時は 小泉成器東日本修理センター TEL 048 718 3340 344 0127 埼玉県春日部市水角1190 小泉成器西日本修理センタ...