3 Instructions for use
You should wash your hands before handling medication or the nebulizer.
1
Connect one end of the tubing to the compressor air outlet.
2
Attach the other end of the tubing into the bottom of the medicine cup.
3
Unscrew the top from the medicine cup.
4
Pour your prescribed medication into the medicine cup, 2-10ml fill.
5
Screw the top back onto the medicine cup and connect the mouthpiece/
mask. Do not lay the SideStream down on its side, because the medication
will spill out.
It is recommended that you replace your SideStream every 6 months.
4 Taking a treatment
• To take the treatment, sit in an upright position and relax.
• Switch on the compressor, supply flow to be 6-8l/min.
• Make sure mist is visibly coming from the mouthpiece/mask.
• Take the mouthpiece between your teeth, surround it with your lips and
breathe in and out slowly through your mouth or place the mask in position
over nose and mouth and breathe slowly in and out through your mouth.
When the SideStream begins to work intermittently and ‘sputters’, then
the treatment is finished. There is no need to nebulize every drop of your
medication, there will always be a small amount left in the medicine cup.
SideStream
Reusable high efficiency nebulizer
1 Important
The SideStream is a compressor-driven nebulizer designed to convert liquid
medication into aerosol for inhalation by the patient.
Please carefully read and understand these instructions before using this product.
If you do not understand any portion of these instructions, contact your
healthcare provider or call Customer Service at 1-800-345-6443 or
1-724-387-4000.
Warning
• Clogged jets or improper assembly may prevent proper delivery of medication.
• To reduce the risk of infection, clean and disinfect the nebulizer between
treatments.
Caution
• Do not try to remove the red jet from the medicine cup. This is
permanently attached.
• Do not towel dry the unit and never use a cleaning brush or put sharp objects
into the jet holes or baffles as this will damage the nebulizer.
• Sidestream reusable is not suitable for use in a ventilator circuit.
• Do not remove top when connected to gas supply.
• Use of 22mm male connectors may reduce output rate.
2 Getting ready
Upon receipt of your SideStream
We recommend that you boil your reusable SideStream (except for tubing) in
water (minimum 212° F) with 2–3 drops of dishwashing liquid for 10 minutes.
This ensures maximum performance.
5 Cleaning
After every use
6
Disconnect the SideStream from the tubing. Unscrew the top from the
medicine cup, rinse out the nebulizer and refill with clean water. Reassemble
top and medicine cup, reconnect the tubing and run SideStream again for a
few seconds to flush out any drug trapped in the nebulizer jets.
7
Take apart the nebulizer.
8
Disconnect tubing from the medicine cup.
9
Wash all items (except tubing) in either hot soapy water or contained within
a basket on the top rack of your dishwasher.
10
Rinse all parts in clean water for 2 minutes.
11
Shake off excess water and allow to air dry. Do not towel dry.
12
Reassemble and store the SideStream in a clean place when not in use.
Once a week
13
Disassemble the nebulizer.
14
Boil the SideStream (except tubing) in water with 2–3 drops of dishwashing
liquid for 10 minutes.
15
Rinse all parts in clean water for 2 minutes.
16
Shake off excess water and allow to air dry. Do not towel dry.
17
Reassemble and store SideStream in a clean place when not in use.
Mouthpiece
Top
Baffle
Medicine cup
Mask
(optional)
1
4
2
5
3
ND
C 0
837
3-0
860-0
0
1
Reu
sab
le n
ebu
liz
er,
mou
thp
iec
e a
nd D
urat
ube
.
For
sin
gle p
atie
nt use
.
Cau
tio
n: F
ede
ral (
U.S
.A
.) l
aw r
est
ric
ts t
his d
evi
ce t
o sal
e by o
r on t
he o
rde
r of a
phy
sic
ian
or l
ice
nse
d h
eal
thc
are
pro
fes
sio
nal
.
1
Neb
uliz
ado
r r
eut
iliza
ble
,
boq
uilla y t
ubo
.
Par
a usa
r en u
n sol
o pac
ien
te.
Pre
cau
ció
n: L
as l
eye
s fed
era
les (
EE.
UU
.) l
im
ita
n la v
ent
a de e
ste d
isp
osit
ivo a u
n
méd
ico
o p
rof
esio
nal s
ani
tar
io c
on l
ice
ncia o
baj
o sus
órd
enes
.
1
Néb
ulis
ate
ur r
éut
ilisa
ble
,
em
bou
t buc
cal e
t un t
ube
.
Pou
r usa
ge p
ar u
n seu
l pat
ien
t.
Mise e
n gar
de : A
ux É
tat
s-U
nis, l
a loi f
édé
ral
e lim
ite l
a ven
te d
e ce d
isp
osit
if
aux m
éde
cin
s ou a
utr
es p
rof
ess
ion
nel
s de l
a san
té d
ûm
ent a
gré
és, o
u sur l
eur
ordon
nan
ce.
Mad
e in C
hin
a / Hec
ho e
n Chi
na / F
abr
iqu
é en C
hin
e
Man
ufa
ctu
red f
or
Res
piro
nic
s Res
pir
ato
ry D
rug D
eliv
ery (
UK
) Ltd
.
Chi
che
ste
r Bus
ine
ss P
ark
, City F
iel
ds W
ay
Tan
gm
ere,
Chi
che
ster
, P
O20
2FT U
K
+1
724
38
7 4
000
800
34
5 6
443
(U
S to
ll f
ree
)
ww
w.p
hili
ps.
com
/re
spi
ron
ics
© 201
3 Koni
nkl
ijk
e Phi
lip
s Ele
ctr
oni
cs N
.V.
All r
igh
ts r
ese
rve
d.
110
881
8 R
00
REF HS860
Side
Stre
am
16089_RRDD_SideStreamKitHS860_1108818_R00_v1.indd 1
7/19/13 10:23 AM