Alignments
6.
6.5
Software upgrade
6.5.1
Hardware
Connect the cable of RS232 with PC COM port by jump wire.
6.5.2
Software
1.
Install the Serial upgrade program
GProbe5.1.0.17.EXE
on
a PC and run it.
2.
Check “Options”, “Connection settings”, “Serial”, “Port” and
“Baud Rate”, see
.
3.
Make a directory called ISP on e.g. C-drive and copy the
files, see
.
4.
The latest Firmware file must be renamed into:
“
fli326xxBx_rd2_32626_board_ext.hex
”.
5.
In the “
Execute
” field enter: “
batch D:\ISP\
isp_spi_ext_Sequoia.txt
”.
6.
Put the set in the Factory mode, see section
7.
Press UP on the remote control to enter Factory Setting
defaults and set the ISP MODE to ON.
8.
Click the Execute button in the GProbe program, see
.
9.
Erasing and programming will start, see
.
10. Monitor will show a black screen. When ready (see GProbe
command window) the monitor will show picture again, see
.
Figure 6-2 Gprobe connection setup