background image

Table of contents

2

K5902107 (451920611682) PS32FHDER 20/03/2018

Содержание PS32FHDER

Страница 1: ...User Guide 32 FHD Color LCD Monitor PS32FHDER ...

Страница 2: ...6 26 22 62 Support www barco com en support Visit us at the web www barco com Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support www barco com en support Visit us at the web www barco com Printed in Italy ...

Страница 3: ...o 13 4 4 Color temperature 13 4 5 Display function 14 4 6 OSD menu position 15 4 7 OSD menu time out 15 4 8 OSD lock 16 4 9 Factory reset 16 4 10 Power over DVI 17 4 11 5 VDC power output 18 5 Cleaning your display 19 5 1 Cleaning instructions 19 6 Important information 21 6 1 Safety information 21 6 2 Environmental information 23 6 3 Biological hazard and returns 25 6 4 Regulatory information 25 ...

Страница 4: ...Table of contents 2 K5902107 451920611682 PS32FHDER 20 03 2018 ...

Страница 5: ...ause considered accidentally touchable by the patient for a time 1 minute The maximum temperature of these parts is about 55 C when the ambient temperature is 40 C CAUTION Read all the important safety information before installing and operating your monitor Please refer to the dedicated chapter in this user guide 1 1 What s in the box Overview The monitor comes with this user guide Keep your orig...

Страница 6: ...ng fixation points VESA 100 mm 2 Cable cover Connections 2 1 4 5 6 7 3 Image 1 3 1 100 240 VAC mains power input IEC C14 2 DVI 1 Single Link input 3 DisplayPort 1 1 input 4 DVI 2 Single Link input 5 5 VDC 500 mA power output 6 USB B 2 0 upstream connector 7 USB A 2 0 downstream connector 4 K5902107 451920611682 PS32FHDER 20 03 2018 ...

Страница 7: ...lation procedure Remove cable cover To get access to the connectors the cable cover should be removed 1 Grab the middle bottom of the cable cover and pull it away from the monitor Image 2 1 Earth monitor 1 Optionally For additional grounding earth the monitor by connecting the protective earth pin to a grounded outlet by means of a wire with at minimum AWG18 size according to national Regulation r...

Страница 8: ...power input to a grounded power outlet 3 2 MAIN INPUT DVI2 DVI1 5V USB B USB A DP 1 Image 2 3 Route cables 1 Route all cables trough the provided cable routing channel at the back of the monitor Use the cable straps at the inside of the connector compartment to fix the cables Image 2 4 Reattach cable cover 1 Slide the 4 position clips on top of the cable cover in the matching fixation holes at the...

Страница 9: ...selected according to the thickness of the VESA plate Please con sider that the maximum length of the available thread for the screws inside the monitor is 6 mm and that the unthreaded distance to the outer surface of the plastic back cover is 7 8 mm Caution Use an arm that is in compliance with VESA requirements Caution Use an arm according to clause 9 8 of IEC 60601 1 considering that the produc...

Страница 10: ...2 Monitor installation 8 K5902107 451920611682 PS32FHDER 20 03 2018 ...

Страница 11: ...ring on ON ORANGE blinking Monitor ON powering on self test ON ON RED static Monitor ON MAX brightness ON ON RED blinking Monitor ON self test FAILED ON GREEN static Monitor ON Video sync OK settings different from default brightness ON GREEN blinking Monitor ON No video sync 3 3 OSD menu use To open the OSD menu If the OSD is locked default setting first press and hold both the and keys for appro...

Страница 12: ... the OSD is locked default setting first press and hold both the and keys for approximately 3 seconds until a pop up warns you that the OSD has been unlocked for about 20 sec Afterwards press the brightness increase or brightness decrease keys to adjust the brightness as desired Or If the OSD is not locked press the brightness increase or brightness decrease keys to adjust the brightness as desire...

Страница 13: ...240 sec OSD Timeout PIN 14 ON PIN 16 ON Off DVI1 5V PIN 14 ON PIN 16 ON Off DVI2 5V On Off OSD Lock On Off 5V Output Factory Reset Settings Backlight operating hours Status 12NC Total operating hours Timing Firmware Version Serial Number Model PSXXXHDXR Info Display Function Color Temperature Aspect Ratio DisplayPort DVI1 DVI2 Native Aspect Native Calibrated Full Screen Native DICOM 1 CAL DICOM TG...

Страница 14: ...2 XXXXX Timing Total operating hours Backlight operating hours Status 1920x1080 60 Hz Image 4 2 4 2 Image source selection About image source selection The monitor can have multiple video inputs connected Switching between the different inputs can be done easily in the OSD menu To select the image source 1 Bring up the OSD main menu 2 Navigate to the Image Source menu 3 Select one of the available...

Страница 15: ... Settings Source Aspect Ratio Color Temperature Display Function DVI2 Full Screen Calibrated Native Image 4 4 4 4 Color temperature About color temperature This setting allows you to modify the monitor white point used as reference for all other colors to be displayed The available color temperature settings for your monitor are Native The native unmodified color temperature of the LCD panel Calib...

Страница 16: ...gy In short the DICOM gamma function results in more visible grayscales in the images It is recommended to select the DICOM gamma function for most medical viewing applications There are 4 different DICOM curves DICOM 1 DICOM output curve suitable for an ambient light level of approximately 20 Lux DICOM 2 DICOM output curve suitable for an ambient light level of approximately 80 Lux DICOM 3 DICOM ...

Страница 17: ...ttings OSD Position menu 3 Select one of the available OSD menu positions Info Image Settings OSD Position OSD Timeout OSD Lock Factory Reset DVI1 5V DVI2 5V 5V Output Center 240 sec Off Off Off Off Image 4 7 4 7 OSD menu time out About the OSD menu time out By default the OSD menu will disappear automatically after approximately 15 seconds of inactivity This time out value can be adjusted to a ma...

Страница 18: ...3 Select On to enable or Off to disable the OSD lock Info Image Settings OSD Position OSD Timeout OSD Lock Factory Reset DVI1 5V DVI2 5V 5V Output Center 240 sec Off Off Off Off Image 4 9 To temporarily unlock and enter the OSD Press and hold both the and keys for approximately 3 seconds until a pop up warns you that the OSD has been unlocked for about 20 sec 4 9 Factory reset About the factory re...

Страница 19: ...ate to the Settings menu 3 Select Factory reset Info Image Settings OSD Position OSD Timeout OSD Lock Factory Reset DVI1 5V DVI2 5V 5V Output Bottom right 15 sec On Off PIN 14 ON On Image 4 10 4 10 Power over DVI About power on DVI This setting allows you to select on which pin of the DVI connector s that the 5 VDC supply is applied or to completely disable the 5 VDC over DVI To adjust the power o...

Страница 20: ...nitor features a 5 VDC power output connector that can be used to connect miscellaneous pe ripherals The power on this connector can be enabled or disabled in the OSD menu To enable disable the 5 VDC power output power connector 1 Bring up the OSD main menu 2 Navigate to the Settings 5V Output menu 3 Select On to enable or Off to disable the 5 VDC power output connector Info Image Settings OSD Pos...

Страница 21: ...ne in 70 isopropyl alcohol Like Cleansafe optical cleaning liquid Do not use following products Alcohol solvents at higher concentration 70 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia at higher concentration 1 6 Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with steel thread CAUTION Take care not to damage or scratch the ...

Страница 22: ...5 Cleaning your display 20 K5902107 451920611682 PS32FHDER 20 03 2018 ...

Страница 23: ...ply Class I equipment Degree of safety flammable anesthetic mixture Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Non patient care equipment Equipment primarily for use in a health care facility that is intended for use in the patient area The equipment may not be used with life support equipment The user should not touch ...

Страница 24: ... matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country Grounding reliability Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle Liquids and moisture Never expose the monitor to liquids or moisture Never use the monitor near water e g near a bathtub washbasin swimming pool ...

Страница 25: ...of this product please contact your local city office or your municipal waste disposal service For details please visit the Barco website at http www barco com en AboutBarco weee Turkey RoHS compliance Türkiye Cumhuriyeti AEEE Yönetmeliğine Uygundur Republic of Turkey In conformity with the WEEE Regulation 中国大陆 RoHS Chinese Mainland RoHS 根据中国大陆 电器电子产品有害物质限制使用管理办法 也称为中国大陆RoHS 以下部分列出了 Barco产品中可能包含的有...

Страница 26: ... in GB T 26572 x 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 标准规定的限量要求 x Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in GB T 26572 在中国大陆销售的相应电子信息产品 EIP 都必须遵照中国大陆 电子电气产品有害物质限制使用标识 要求 标准贴上环保使用期限 EFUP 标签 Barco产品所采用的EFUP标签 请参阅实例 徽标内部的编 号使用于指定产品 基于中国大陆的 电子信息产品环保使用期限通则 标准 All Electronic Information ...

Страница 27: ...ral law restricts this device to sale by or on the order of a physician Details exemptions are in the Code of Federal Regulations Title 21 801 Part D Manufacturing country The manufacturing country of the product is indicated on the product label Made in Importers contact information To find your local importer contact one of Barco s regional offices via the contact information provided on our web...

Страница 28: ...t supplies buildings used for domestic purposes This PS32FHDER complies with appropriate medical EMC standards on emissions to and interference from surrounding equipment Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interfer ence that may cause undesired operation Interference...

Страница 29: ...UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5s Mains power quality should by that of a typical commercial or hospital environment If the user of the PS32FHDER requires continued operation during power mains interruptions it is recommended that the PS32FHDER be powered from an uninterruptible power supply or a battery Power fr...

Страница 30: ...the PS32FHDER can help prevent electromagnetic interfer ence by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the PS32FHDER as recommended below according to the maximum output power of the communications equipment 2 Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios a...

Страница 31: ...s the device meets the requirements of the applicable EC directives Indicates compliance with Part 15 of the FCC rules Class A or Class B Indicates the device is approved according to the UL Recognition regulations Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations Indicates the device is approve...

Страница 32: ...ricts this device to sale by or on the order of a licensed healthcare practitioner Indicates the device is approved according to the BIS regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the legal manufacturer Indicates the manufacturing date Indicates the temperature limitations5 for the device to safely operate within specs Indica...

Страница 33: ...icates a device that can be broken or damaged if not handled carefully when being stored Indicates a device that needs to be protected from moisture when being stored Indicates the storage direction of the box The box must be transported handled and stored in such a way that the arrows always point upwards 15 n or n Indicates the maximum number of identical boxes which may be stacked on each other...

Страница 34: ... NV or Barco Inc and the licensee No other use duplication or disclosure of a Barco software product in any form is authorized The specifications of Barco products are subject to change without notice Trademarks All trademarks and registered trademarks are property of their respective owners Copyright notice This document is copyrighted All rights are reserved Neither this document nor any part of...

Страница 35: ...kaged W x H x D 770 x 480 x 1100 mm Net weight 11 5 0 5 kg Net weight packaged 13 6 0 5 kg Mounting standard VESA 100 mm Recommended modalities IGT Certifications EN 60601 1 2006 A1 2013 IEC 60601 1 2005 CORR 1 2006 CORR 2 2007 A1 2012 ANSI AAMI ES60601 1 R 2012 and A1 2012 C1 2009 R 2012 CAN CSA ES60601 1 2014 IEC 60529 1991 A1 2000 Degrees of protection IP code IEC 62471 2006 EN 62471 2008 Photo...

Страница 36: ... 8 mm 746 2 mm 87 2 mm 323 1 mm 100 0 mm 100 0 mm 173 9 mm 173 9 mm Image 6 1 Identification label position The product identification label is located at the back of the monitor under the cable cover as illustrated below 34 K5902107 451920611682 PS32FHDER 20 03 2018 ...

Страница 37: ...6 Important information Image 6 2 K5902107 451920611682 PS32FHDER 20 03 2018 35 ...

Страница 38: ......

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ...K5902107 01 451920611682 March 2018 FIMI S r l Saronno Italy Barco NV Beneluxpark 21 8500 Kortrijk Belgium Registered address President Kennedypark 35 8500 Kortrijk Belgium ...

Отзывы: