Connecting Power
9
PLPROFILE4 MKII LED Luminaires
Installation & User’s Manual
3. Connecting Power
Note:
Refer to
Figure 1 on page 7
for AC Input and Output connections.
If the unit is supplied with an AC input cable,
Table 1
describes how to connect power to your PLPROFILE4 MKII
LED Luminaire . Field wiring of the PLPROFILE4 MKII LED Luminaire is straight forward. A total of 3 wires/
conductors need to be brought to the unit. The following wiring scheme is required:
Table 1:
PLPROFILE4 MKII LED Luminaire AC Input
Connections
4. Connecting to the DMX512 Network
Note:
Refer to
Figure 1 on page 7
for DMX512 Input and Output/Thru connections.
Basic DMX512 installation consists of connecting multiple PLPROFILE4 MKII LED Luminaires together (up to 30
luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX
connector on the first PLPROFILE4 MKII LED Luminaire. Another cable runs from the other DMX connector on the
first unit to a DMX connector on the next PLPROFILE4 MKII LED Luminaire (or DMX512 device to be controlled).
Note:
For more information on DMX512 networking and systems, refer to
"Additional Resources for DMX512" on
page 1
. For PLPROFILE4 MKII LED Luminaire DMX Mapping, refer to
"DMX CONTROL" on page 23
.
Figure 2: Connecting DMX512
Wire Color
Purpose
Brown
Main / Line (120 to 240VAC)
Blue
Neutral
Green/Yellow
Ground
Neutral
Main /
Ground / Earth
Line
AC Input Connector
(on back of unit)
DMX512
DMX512
(out from first
to second luminaire)
DMX512
(out to the next luminaire or
DMX512 controlled device)
PLPROFILE4 LED Luminaires
DMX512 Connections
Note: Remaining pins on each connector are not used.
DMX512 Signal
XLR Pin
Common (Drain)
1
DMX512 -
2
3
(from console or
control device)