background image

Type

Diameter

M.O.L.

(In.)

(In.)

500PAR56Q/NSP

7

5

500PAR56Q/MFL

7

5

500PAR56Q/WFL

7

5

1000PAR64Q/NSP

8

6

1000PAR64Q/MFL

8

6

1000PAR64Q/WFL

8

6

FFN

8

6

FFP

8

6

FFR

8

6

FFS

8

6

Diameter

M.O

.L.

Rated 

Std.

Heat 

Average Approx.

Product ANSI

Pkg.

Resistant

Bulb 

Beam

Candle-

Initial

Life

Color

Number

Description

Code

Watts

Qty. Volts

Description

Type

Base

Angle

1

Power

2

Lumens

(Hrs.)

3

Temp.

35619-6

500PAR56Q/NSP

500

8

120

Narrow Spot

PAR-56

Mog. End

17 x 34

88,000

3500

4000

3000

35621-2

500PAR56Q/MFL

500

8

120

Med. Flood

PAR-56

Mog. End

20 x 48

47,000

3800

4000

3000

35620-4

500PAR56Q/WFL

500

8

120

Wide Flood

PAR-56

Mog. End

28 x 70

22,500

5000

4000

3000

27555-2

1000PAR64Q/NSP

1000

8

120

Narrow Spot

PAR-64

Ext. Mog End

16 x 28

200,000

9800

4000

3000

27556-0

1000PAR64Q/MFL

1000

8

120

Med. Flood

PAR-64

Ext. Mog End

24 x 44

80,000

12,000

4000

3000

27558-6

1000PAR64Q/WFL

1000

8

120

Wide Flood

PAR-64

Ext. Mog End

42 x 76

31,000

14,800

4000

3000

34350-9

1000PAR64QVNSP

FFN

1000

8

120

Very Narrow Spot

PAR-64

Ext. Mog End

12 x 6

400,000

11,000

800

3200

34351-7

1000PAR64QNSP

FFP

1000

8

120

Narrow Spot

PAR-64

Ext. Mog End

14 x 7

330,000

12,000

800

3200

34352-5

1000PAR64QMFL

FFR

1000

8

120

Med. Flood

PAR-64

Ext. Mog End

28 x 12

120,000

14,000

800

3200

34353-3

100PAR64QWFL

FFS

1000

8

120

Wide Flood

PAR-64

Ext. Mog. End

55 x 22

40,000

19,000

800

3200

Tungsten Halogen PAR Lamps

Electrical,Technical and Ordering Data 

(Subject to change without notice)

Philips Lighting Company 
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation 

Printed in USA 07/05

P-1223-D

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050  

A Division of Philips Electronics Ltd.

www.philips.com

1) Beam Spread to 50% peak candlepower.
2) Candlepower Average in central 5˚ cone for spot to 10˚ cone for flood.
3) Rated Average Life is the length of operation (in hours) at which point an average of 50% of the lamps will still be operational and 50% will not.
Note: Lamps can be operated in ANY position.

Operation & Handling

Studio and theater lamps require care to gain
optimum performance with every use. Handling
the glass of a quartz lamp should be avoided. It is
advisable to use gloves when touching a lamp.
Should the lamp be touched, careful cleaning can
be done with a solvent such as alcohol. Shielding
of halogen lamps is generally considered an 
advisable precaution.

Average Performance Characteristics

Fig. 1 and Fig. 2 — Data becomes more 
inaccurate beyond 80–120%. Overvolting Stage
and Studio lamps can result in immediate failure;
undervolting increases live expectancy while
reducing color temperature.

Fig. 1   

Variation of life characteristics 
with applied voltage

300

260

220

180

140

100

60

20

88

92

96

100

104

108

Percentage Life

Percentage Rated Volts

Fig. 2   

Variation of light characteristics 
with applied voltage

 

 

 

 

140

100

60

20

88

92

96

100

104

108

Percentage Life

Percentage Rated Volts

Lumens

Watts

Отзывы: