Type
Diameter
M.O.L.
(In.)
(In.)
500PAR56Q/NSP
7
5
500PAR56Q/MFL
7
5
500PAR56Q/WFL
7
5
1000PAR64Q/NSP
8
6
1000PAR64Q/MFL
8
6
1000PAR64Q/WFL
8
6
FFN
8
6
FFP
8
6
FFR
8
6
FFS
8
6
Diameter
M.O
.L.
Rated
Std.
Heat
Average Approx.
Product ANSI
Pkg.
Resistant
Bulb
Beam
Candle-
Initial
Life
Color
Number
Description
Code
Watts
Qty. Volts
Description
Type
Base
Angle
1
Power
2
Lumens
(Hrs.)
3
Temp.
35619-6
500PAR56Q/NSP
500
8
120
Narrow Spot
PAR-56
Mog. End
17 x 34
88,000
3500
4000
3000
35621-2
500PAR56Q/MFL
500
8
120
Med. Flood
PAR-56
Mog. End
20 x 48
47,000
3800
4000
3000
35620-4
500PAR56Q/WFL
500
8
120
Wide Flood
PAR-56
Mog. End
28 x 70
22,500
5000
4000
3000
27555-2
1000PAR64Q/NSP
1000
8
120
Narrow Spot
PAR-64
Ext. Mog End
16 x 28
200,000
9800
4000
3000
27556-0
1000PAR64Q/MFL
1000
8
120
Med. Flood
PAR-64
Ext. Mog End
24 x 44
80,000
12,000
4000
3000
27558-6
1000PAR64Q/WFL
1000
8
120
Wide Flood
PAR-64
Ext. Mog End
42 x 76
31,000
14,800
4000
3000
34350-9
1000PAR64QVNSP
FFN
1000
8
120
Very Narrow Spot
PAR-64
Ext. Mog End
12 x 6
400,000
11,000
800
3200
34351-7
1000PAR64QNSP
FFP
1000
8
120
Narrow Spot
PAR-64
Ext. Mog End
14 x 7
330,000
12,000
800
3200
34352-5
1000PAR64QMFL
FFR
1000
8
120
Med. Flood
PAR-64
Ext. Mog End
28 x 12
120,000
14,000
800
3200
34353-3
100PAR64QWFL
FFS
1000
8
120
Wide Flood
PAR-64
Ext. Mog. End
55 x 22
40,000
19,000
800
3200
Tungsten Halogen PAR Lamps
Electrical,Technical and Ordering Data
(Subject to change without notice)
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in USA 07/05
P-1223-D
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
1) Beam Spread to 50% peak candlepower.
2) Candlepower Average in central 5˚ cone for spot to 10˚ cone for flood.
3) Rated Average Life is the length of operation (in hours) at which point an average of 50% of the lamps will still be operational and 50% will not.
Note: Lamps can be operated in ANY position.
Operation & Handling
Studio and theater lamps require care to gain
optimum performance with every use. Handling
the glass of a quartz lamp should be avoided. It is
advisable to use gloves when touching a lamp.
Should the lamp be touched, careful cleaning can
be done with a solvent such as alcohol. Shielding
of halogen lamps is generally considered an
advisable precaution.
Average Performance Characteristics
Fig. 1 and Fig. 2 — Data becomes more
inaccurate beyond 80–120%. Overvolting Stage
and Studio lamps can result in immediate failure;
undervolting increases live expectancy while
reducing color temperature.
Fig. 1
Variation of life characteristics
with applied voltage
300
260
220
180
140
100
60
20
88
92
96
100
104
108
Percentage Life
Percentage Rated Volts
Fig. 2
Variation of light characteristics
with applied voltage
140
100
60
20
88
92
96
100
104
108
Percentage Life
Percentage Rated Volts
Lumens
Watts