Product Ordering
Pkg
Bulb
Rated
Avg.
Approx.
Class
MOL
Number
Code
Watts
Volts
Qty.
Description
Type
Base
Life, Hours
1
MBCP
2
Lumens
Filament
(In.)
Cool Beam
38884-3
60PAR38/HAL/2FL
60
130
12
Flood 25°
PAR-38
Medium
3000
2500
770
C, CC-8
5
5
⁄
16
Ratings @ 120V = 53W
Standard
6000
700
Reflector
38886-8
90PAR38/HAL/2FL
90
130
12
Flood 25°
PAR-38
Medium
2500
4500
1350
C, CC-8
5
5
⁄
16
Ratings @ 120V = 79W
Standard
5000
1000
Reflector
Side Prong
38887-6
60PAR38/HAL/3FL
60
120
12
Flood 25°
PAR-38
Medium
3000
3000
770 C, CC-8
4
1
⁄
16
Standard Side
Prong
Reflector
38890-0
90PAR38/HAL/3FL
90
130
12
Flood 25°
PAR-38
Medium
2500
4500
1350
C, CC-8
4
1
⁄
16
Ratings @ 120V = 79W
Standard Side
Prong
5000
1000
Reflector
Ordering and Shipping Data
Outer
Case Case
SKUs
SKU
Case
Pallet
Product
SKU UPC
Bar Code
Case Weight Cube
Pallet
Per
Layers Dimensions
Dimensions
Dimensions
Number
(0 46677-)
(5 0046677-)
Qty.
(lbs.)
(cu. ft.)
Qty.
Layer
High
(W x D x H) (In.)
(W x D x H) (In.)
(W x D x H) (In.)
Cool Beam
38884-3
38884 3
38884 8
12
10
0.95
720
180
4
4.63 x 4.63 x 5.69
9.44 x 14.31 x 12.13
42.93 x 47.20 x 48.52
38886-8
38886 7
38886 2
12
10
0.95
720
180
4
4.63 x 4.63 x 5.69
9.44 x 14.31 x 12.13
42.93 x 47.20 x 48.52
Side Prong
38887-6
38887 4
38887 9
12
10
0.95
720
180
4
4.63 x 4.63 x 5.69
9.44 x 14.31 x 12.13
42.93 x 47.20 x 48.52
38890-0
38890 4
38890 9
12
10
0.95
720
180
4
4.63 x 4.63 x 5.69
9.44 x 14.31 x 12.13
42.93 x 47.20 x 48.52
1) Rated average life is the length of operation (in hours) at which point an average of
50% of the lamps will still be operational and 50% will not.
2) Maximum Beam Candlepower
NOTICE:
To avoid deterioration of lampholder by heat, use only heat resistant
lampholders of fixtures listed by a nationally recognized electrical testing organization
for use with reflector or PAR lamps.
PAR HALOGEN CAUTION NOTICE:
Before using bulb, see operating instructions
on inside flap. Adherence to the operating instructions will reduce the risk of personal
injury or fire. The filament capsule contained inside this glass bulb is pressurized, operates
at high temperature and could unexpectedly shatter. Should the outer bulb break,
par ticles of extremely hot glass could be discharged into the fixture and/or the
surrounding environments, thereby creating a risk of personal injury or fire.
OPERATING INSTRUCTIONS:
Before replacing, turn of power and let lamp cool to
avoid electrical shock or burn.
– For indoor or outdoor use. A weather-protected fixture is recommended for wet locations.
– Suitable for use in open fixtures.
– Do not exceed the maximum wattage rating of the fixture.
– Do not use if outer glass is scratched or broken since it may break during operation
or removal.
– If outer glass breaks the lamp may continue to light, however, immediately discontinue use.
– Due to heat that radiates from the bulb, do not use in close proximity to combustible
materials or objects susceptible to drying or fading.
– Manage in accord with disposal laws.
Philips Cool Beam and Side Prong PAR38 Lamps
Electrical,Technical and Ordering Data
(Subject to change without notice)
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in USA 07/05
P-2558-C
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com