Electrical,Technical and Ordering Data
(Subject to change without notice)
Philips Advantage T12 Fluorescent Lamps Featuring ALTO
®
Lamp Technology
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in USA 6/05
P-2497-E
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
Approx.
Rated
Color
Color
Nominal
Product
Ordering
Product
Ordering
Length Initial
Design
Average
Temp.
Rendering
Watts
Number
Code
Number
Code
Bulb
(In.)
Lumens
1
Lumens
2
Life (Hrs.)
3
(Kelvin) Index (CRI)
34
23781-8
F34/30U/RS/EW/ALTO
14257-0
F34T12/ADV830/EW/ALTO
T12
48
3100
2945
24,000
3000
85
34
23782-6
F34/35U/RS/EW/ALTO
14258-8
F34T12/ADV835/EW/ALTO
T12
48
3100
2945
24,000
3500
85
34
23783-4
F34/41U/RS/EW/ALTO
14259-6
F34T12/ADV841/EW/ALTO
T12
48
3100
2945
24,000
4100
85
34
23784-2
F34/50U/RS/EW/ALTO
14260-4
F34T12/ADV850/EW/ALTO
T12
48
2950
2800
24,000
5000
85
40
27298-9
F40/30U/ALTO
26604-9
F40T12/ADV830/ALTO
T12
48
3600
3420
24,000
3000
85
40
27299-7
F40/35U/ALTO
26631-2
F40T12/ADV835/ALTO
T12
48
3600
3420
24,000
3500
85
40
27309-4
F40/41U/ALTO
26640-3
F40T12/ADV841/ALTO
T12
48
3600
3420
24,000
4100
85
40
27315-1
F40/50U/ALTO
26643-7
F40T12/ADV850/ALTO
T12
48
3450
3280
24,000
5000
85
Old Product:
Ultralume
New Product:
Advantage
1) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions.
For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the
designated lamp lumen output.
2) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.
3) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
E
N
VIR
O N M
EN
T
B
E
TT
ER FOR T
H
E
†
†
This fluorescent lamp is better for the environment because of its reduced mercury content. All fluorescent lamps
contain mercury for effective operation, however, Philips lamps with ALTO
®
Lamp Technology average 70% less
mercury than the 2001 industry average for fluorescent lamps up to sixty inches which are not TCLP-compliant.