3-1
Various
other Tests
Activated with
ACTION
TEST
S
S
to Exit
EEPROM FORMAT
TEST
Load default data. Display shows "NEW".
Caution!
All presets from the customer will be lost!!
Disconnect
mains cord
LEAVE SERVICE
TEST PROGRAM
Volume
Knob
ROTARY
ENCODER TEST
Display shows value for 2 seconds.
Volume values increases or decreases in steps of 1
until 0 (VOL MIN) or 40 (VOL MAX) is reached.
Y
N
Y
N
N
B
II
Button pressed?
B
II
Button pressed?
DISPLAY
TEST
Display shows Figure 1
and switch "SACD" LED on
Display shows Figure 2
and switch "SACD" LED off
Y
9
Button pressed?
Figure 1
Figure 2
To start service test program
hold
B
II and
buttons depressed while
plugging in the mains cord
Display shows
"SERVICE"
followed by ROM version
"S-Vxx-yy"
S refers to Service Mode
V refers to Version
xx refers to Software version number of BEA
(counting up from 01 to 99)
yy refers to Software version number of Front uP
(counting up from 01 to 99)
SERVICE TEST PROGRAM
LX8300SA & LX8320SA & LX8500W_Service Test Program_dd wk0429
MAIN MENU
Hold
B
II and buttons depressed
till the Display shown "S-Vxx-yy"
S
S