background image

5

Eng

SAFETY PRECAUTIONS

This label may appear on the bottom of the unit
due to space limitations.

THE LIGHTNING FLASH WITH AN
ARROWHEAD SYMBOL, WITHIN
AN EQUILATERAL TRIANGLE, IS
INTENDED TO ALERT THE USER
TO THE PRESENCE OF UN-INSU-
LATED “DANGEROUS VOLTAGE”
WITHIN THE PRODUCT’S ENCLO-
SURE THAT MAY BE OF SUFFIC-
IENT MAGNITUDE TO CONSTI-
TUTE A RISK OF ELECTRIC SHOCK
TO PERSONS. 

The exclamation point within an equi-
lateral triangle is intended to alert the
user to the presence of important
operating and maintenance (servicing)
instructions in the literature accompa-
nying the appliance.

Note: A note alerts the user or installer to
special installation or operating procedures.
The hand symbol in a circle indicates a
note.

Caution: Installation should be per-
formed by qualified service personnel
only in accordance with the National
Electrical Code or applicable local
codes.

CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
OPEN COVERS. NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

WARNING: TO PREVENT FIRE OR
SHOCK HAZARD, DO NOT
EXPOSE UNITS NOT SPECIFICALLY
DESIGNED FOR OUTDOOR USE
TO RAIN OR MOISTURE.

COVER REMOVAL

Caution: Power Disconnect. Units
with or without ON-OFF switches
have power supplied to the unit
whenever the power cord is inserted
into the power source; however, the
unit is operational only when the
ON-OFF switch is in the ON posi-
tion. The power cord is the main
power disconnect for all units.

Caution: External Power Supplies
use only the Recommended Power
Supplies. Power supplies must com-
ply with the requirements of the lat-
est version of IEC 65/VDE 0860. Sub-
stitutions may damage the unit or
cause a fire or shock hazard.

WARNING: REMOVAL OF THE
COVER SHOULD ONLY BE PER-
FORMED BY QUALIFIED SERVICE
PERSONNEL - NOT USER SER-
VICEABLE. THE UNIT SHOULD
ALWAYS BE UNPLUGGED
BEFORE REMOVING THE COVER,
AND REMAIN UNPLUGGED
WHILE THE COVER IS REMOVED.

Содержание LBC 2502/10

Страница 1: ...Philips Communication Security Systems Call Station Extension LBC 2502 10 SM25B SoundManagement Instructions for Use Eng F D E NL I ...

Страница 2: ...2 GB Installation Instructions 5 F Instructions d installation 8 D Installationsanleitung 11 E Instalación de uso 14 NL Installatievoorschrift 17 I Istruzioni per d installazione 20 ...

Страница 3: ... or local power company For units intended to operate from battery power or other sources refer to the operating instructions 11 Grounding or Polarization This unit may be equipped with a polarized alternating cur rent line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug fully into...

Страница 4: ...ed protection of this unit during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and discon nect the cable system This will prevent damage to the unit due to lightning and power line surges FCC ICES INFORMATION U S A and Canadian Models Only WARNING THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B D...

Страница 5: ... applicable local codes CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT OPEN COVERS NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE UNITS NOT SPECIFICALLY DESIGNED FOR OUTDOOR USE TO RAIN OR MOISTURE COVER REMOVAL Caution Power Disconnect Units with or without ON OFF switches have power supplied to the unit w...

Страница 6: ...n illuminate fig 2a Note Zones or groups of zones that have already been selected can be de selected by pressing the selection button again Press and hold the PTT button on the Call Station If the chime feature is selected the on air indicator will flash during the chime It is not possible to make a call while this indicator is flashing fig 2b When the on air indicator illuminates continuously the...

Страница 7: ...6 by toggling the corresponding buttons 1 to 6 the LEDs next to the selected zone s illuminate 4 Press button 8 to store the zone selection in the group 1 to 6 the selected LEDs go out LED 8 remains flashing to indicate program mode Note The buttons on a single Call Station Extension can also be programmed to activate zones 7 to 12 If any zone s in the group 7 to 12 have been previously selected t...

Страница 8: ...23 1 2 3 b c a 4 ...

Страница 9: ...stems 3922 988 54782 40 99 1999 by Philips Electronics N V 1999 by Philips Communication Security Systems Inc All Rights Reserved Philips is a registered trademark of Philips Electronics N A Corp Data subject to change without notice 5 ...

Отзывы: