background image

4. PREPARATIONS BEFORE USING THE

RECEIVER

4.1Hardware setting

1. Opening the housing
-

Slide the battery lock (fig.5B) open in the direction of the clip.

-

Remove the battery cover (fig.5A).

-

Remove the batteries.

2. Separating housing parts
To get access to the solder links, the housing parts must be
separated as follows:
-

Slide down the housing attachment (fig.5D) inside the battery
compartment with the help of a small screwdriver.

-

Pull the housing parts away at the bottom with the thumbs
(fig.5C) and open the housing hooks first at the bottom.

-

Remove the housing part with the clip only and leave the PCB
assembly in the other housing part.

3. Solder links
-

Battery saving circuit
Solder link (fig.6A) for 5F5F pre-amble string encoders only. 
Factory default setting is “disable”. To enable battery saving,
close solder link (A).

-

Decimal group call
The receiver recognises one or more of the address digit
locations 2, 3 and 4 when they are equal “F”.
Factory default setting is “enable”. To ‘disable’ the decimal
group call, close solder link (B).

-

Accu mode (PCB version 5 and higher)
Make solder link (D) to enable receivers ‘on’ in accu mode.
Older version PCB’s are always on in the accu mode.

-

UHF front end module
Solder link (C) for factory use only.
VHF module. Solder link C is open
UHF module. Solder link C is closed

INSTALLATION INSTRUCTION  77

DP 6000 DIGITAL PAGING SYSTEM 

Page 3/5

June 1992

II

I

0

C

D

A

B

E

II

I

0

P

N

C H

C

E

A

B

D

A

B

C

D

Battery cover

Opening housing

Numeric PCB layout

Содержание LBB 6186

Страница 1: ...upler LBB 5840 xx and the LBB 6000 Alpha desk user editor edit menu receives 2 OPERATING CONTROLS AND DISPLAYS 2 1Operating Controls 2 1 1 ON OFF volume switch fig 1B position 0 off position I on with low bleep volume position II on with high bleep volume When switching on a single bleep is emitted and the personal address is shown on the display if present With rechargeable batteries installed th...

Страница 2: ...switched off with a high volume bleep The receiver also contains a back up battery to supply the receiver memory when exchanging the main batteries 2 Battery saving When the battery saving mode has been enabled see 4 1 3 the receiver is switched on off by means of the 5F5F pre amble string Battery saving is not possible with the older encoder types LBB 59xx The encoders LBB 5900 10 and LBB 5840 xx...

Страница 3: ...t 3 Solder links Battery saving circuit Solder link fig 6A for 5F5F pre amble string encoders only Factory default setting is disable To enable battery saving close solder link A Decimal group call The receiver recognises one or more of the address digit locations 2 3 and 4 when they are equal F Factory default setting is enable To disable the decimal group call close solder link B Accu mode PCB v...

Страница 4: ...splay again One call address must be programmed A not programmed address contains the default value C C C C A decimal group call is transmitted when the address contains an F in the 3 least significant digits xxxF xxFx or xFxx A decimal group call is possible with the normal call address and the group call addresses Decimal group calls can be disabled by a solder link on the PCB Receivers can alwa...

Страница 5: ... 8A by releasing the hook fig 8B First remove the clip from the right hinge position by pressing it upwards Now the left hinge can easily be removed The clip carrier can be removed by loosing the 2 screws fig 8C When no clip is used the 2 small cups fig 8D stored behind the clip carrier can be used for covering the screw holes Consult your local Philips representative or sales office for other pos...