background image

1.12

1.14

1. N/C

4. Remote Alarm Contact

2. N/C

5. Remote Alarm Contact

3. N/C

1.13

1. N/C
2. N/C
3. N/C
4. Remote Contact
5. Remote Contact

ON

ON

OFF

OFF

Switch

Signal

On/Off activation with key released alarm signals

1.15

ON

ON

OFF

OFF

Switch

Signal

Fixed time

Fixed time

On/Off activation with fixed time alarm and time signals

1.16

ON

ON

OFF

OFF

Switch

Signal

Pulse on/Pulse off activation with key released alarm signals

1.17

1.18

Содержание LBB 2540/10

Страница 1: ...Philips Communication Security and Imaging Alarm Routing Module LBB 2540 10 SM25B SoundManagement Installation Instructions Eng F D E NL I ...

Страница 2: ...Eng Installation Instructions 5 F Instructions d installation 13 D Installationsanleitung 22 E Instalación de uso 30 NL Installatievoorschrift 39 I Istruzioni per d installazione 47 2 ...

Страница 3: ... marking label If you are not sure of the type of power supply you plan to use consult your appliance dealer or local power company For units intended to operate from battery power or other sources refer to the operating instructions 11 Grounding or Polarization This unit may be equipped with a polarized alternating current line plug a plug having one blade wider than the other This plug will fit ...

Страница 4: ...xhibits a distinct change in performance this indicates a need for service 18 Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards 19 Safety Check Upon completion of any service o...

Страница 5: ... applicable local codes CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT OPEN COVERS NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE UNITS NOT SPECIFICALLY DESIGNED FOR OUTDOOR USE TO RAIN OR MOISTURE COVER REMOVAL Caution Power Disconnect Units with or without ON OFF switches have power supplied to the unit w...

Страница 6: ...rconnection Module LBB 2505 10 GMM General Mixing Module LBB 2510 10 HGS Hand grip Set LBC 1501 00 INT Internal LED Light emitting diode indicator Mic Microphone MIX Mixing Input Module LBB 2516 10 MXF Module Extension Frame LBB 2500 00 MZS Manual Zone Switch LBB 2550 00 NC Not connected PCB Printed Circuit Board PCF Power Consumption Factor PSM Power Supply Module LBB 2502 10 PTT Press to talk bu...

Страница 7: ...figuring the ARM 10 ARM configuration switches 10 1 4 Trouble shooting the ARM 12 WARNING READ THE IMPORTANT SAFETY INSTRUCTIONS BEFORE INSTALLING THIS EQUIPMENT REFERENCE DOCUMENTATION The following documents are referred to in this installation instructions Installation Instructions Instructions for use Booster Frame 3922 988 52281 Booster Frames 3922 988 52681 MXF 3922 988 53581 ...

Страница 8: ... signal switching contacts must be set to normally open For more information refer to section 1 3 Alarm and time signal Inputs The ARM must be configured so that either the alarm signals or time signals are routed to preselected zones or group of zones If the alarm signals are routed to preselected zones or group of zones the time signals are routed to all zones all call and vice versa A priority ...

Страница 9: ...int all switches on the PCB are accessible If the ARM is to be configured refer to section 1 3 2 Insert the ARM and push it completely home fig 1 7 3 Tighten the captive Torx screw on top of the front panel fig 1 8 detail A 4 The SM 25B Booster Frame is connected to the ARM via a flexible 16 pole system cable This IDC flat cable runs from the Booster Frame PCB along the top of the Booster Frame fi...

Страница 10: ... OFF S301 6 Normally open closed 3 Normally closed 7 Normally open S301 7 Interruption deactivation 3 Deactivation 7 Interruption S301 8 Zone selection 3 Alarm All call Time pre select 7 Time All call Alarm pre select S302 1 2 3 4 5 6 7 8 Zone selection 1to 8 Select any combination of zones 1 to 8 using DIP switches 1 to 8 respectively S303 1 2 3 4 Zone selection 9 to 12 Select any combination of ...

Страница 11: ... predetermined time If a deactivation signal arrives before the end of the predetermined time it has no effect These activation and deactivation properties are illus trated in figs 1 15 to 1 18 inclusive To select Pulse or ON OFF Set switch 5 on DIL switch S301 to ON for pulse OFF for ON OFF It is necessary to select whether the alarm is activated by closing switching contacts which are normally o...

Страница 12: ...hooting the ARM To trouble shoot the ARM it is recommended that the following points be investigated If the output volume is too high or low adjust the output volume using level control R233 Ensure that the external switch es correspond to the ARM settings such as normally open and normally closed This ensures that the ARM correctly recognizes the alarm signal Ensure that the connections at the ba...

Страница 13: ...1 1 1 2 1 3 ...

Страница 14: ...t 5 Remote Contact ON ON OFF OFF Switch Signal On Off activation with key released alarm signals 1 15 ON ON OFF OFF Switch Signal Fixed time Fixed time On Off activation with fixed time alarm and time signals 1 16 ON ON OFF OFF Switch Signal Pulse on Pulse off activation with key released alarm signals 1 17 1 18 ...

Страница 15: ...58 1 19 ...

Страница 16: ...This page left intentionally blank 59 ...

Страница 17: ... Imaging 3922 988 92381 09 00 2000 by Philips Electronics N V 2000 by Philips Communication Security Systems Inc All Rights Reserved Philips is a registered trademark of Philips Electronics N A Corp Data subject to change without notice ...

Отзывы: