Table of Contents

1

About this Guide

5

About the Data Export Test Tool

5

Manufacturer's Information

6

Trademark Information

6

2

DETT - Instructions for Use

7

Installation of DETT

7

Un-Installation of DETT

7

Deletion of Log Files

7

System Requirements for DETT

8

How to start DETT

8

The Menu

9

System List Window

14

System Detail Window

16

Debug Information Window

21

Log Files

21

DETT overview example

22

How to connect a PC with DETT to an IntelliVue

23

Index

25

Содержание IntelliVue MP2

Страница 1: ...Instructions for Use Data Export Test Tool MP2 X2 MP5 20 30 40 50 60 70 80 90 MX800 ...

Страница 2: ...Part Number 453564254321 Printed in Germany 01 11 453564254321 ...

Страница 3: ...DETT Instructions for Use 7 Installation of DETT 7 Un Installation of DETT 7 Deletion of Log Files 7 System Requirements for DETT 8 How to start DETT 8 The Menu 9 System List Window 14 System Detail Window 16 Debug Information Window 21 Log Files 21 DETT overview example 22 How to connect a PC with DETT to an IntelliVue 23 Index 25 ...

Страница 4: ...4 ...

Страница 5: ... user or patient A caution alerts you where special care is necessary for the safe and effective use of the product Failure to observe a caution may result in minor or moderate personal injury or damage to the product or other property and possibly in a remote risk of more serious injury About the Data Export Test Tool DETT is used to test the communication interface protocol which transfers data ...

Страница 6: ...warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Philips shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Trademark Information Microsoft is a U S registered trademark of Microsof...

Страница 7: ...ation xml DataExportTestTool chm DETT exe MdilDataTypes dll Tnlscat x PluginInterfaces dll DETT Plugins ConnectionStatePlugin dll DataStorePlugin dll DiscoverPlugin dll DiscoverSerialPlugin dll Un Installation of DETT Delete the DETT installation directory including DETT exe Log files deletion Delete DETT log files either in the default program directory or the selected log files path refer to Fil...

Страница 8: ...MB RAM required 1GB recommended Free hard disk space About 2 MB for the zip file and less than 10 MB for the extracted tool excl stored log files NOTE Future releases of the DETT may require more hard disk space Network Interface Card with 10BaseT half duplex It is recommended that you install the latest driver available for your Network Card RS 232 interface to communicate with the IV MIB RS 232 ...

Страница 9: ...tarting the application the main window is displayed No system data is displayed The application window consists of these main areas 1 Menu 2 System List Window 3 System Details Window 4 Debug Information Window 5 Status Strip 6 Frame Border which can be dragged to change split screen size Refer to chapter DETT overview example for an example of how DETT displays connected patient monitor devices ...

Страница 10: ...ation to import a new NLS text catalog file change the default path for the log files or change the baud rate of the COM interface When selecting Change path the log file path can be adapted to any PC or network directory The default path for the log files is given by the installation path of the DETT ...

Страница 11: ... the COM interface 19200 or 115200 NLS The NLS text catalog Tnlscat X can be be imported to achieve full text compatibility between the DETT tool and the Monitor Rev If the text string of transmitted data is incorrect this might be solved by an upgrade of the NLS text catalog For further information please refer to the respective Service Documentation for the patient monitors The NLS text catalog ...

Страница 12: ...2 DETT Instructions for Use 12 File Exit From the File file pull down menu select Exit to exit the DETT This will terminate the program including all open threads ...

Страница 13: ...PC without a BootP Server in the LAN network e g direct LAN Connection the PC must use a valid IP address within the same subnet as the IV To start the data export communication select Start from the Menu By selecting Start from the Menu the DETT detects any available connected IntelliVue Patient Monitors and displays the received data in the numeric grid Patient Monitors connected via LAN can tak...

Страница 14: ...he connection to all monitors is terminated Logging is stopped as well Help About In the pull down menu Help and About can be accessed Help Select Help to open the main help file About Select About to open the About box The picture below shows an example of the About box To exit the About box select OK ...

Страница 15: ... Strip The Status Strip shows the current status of the DETT The following status messages are displayed 1 Ready DETT is launched and ready to be started 2 Running DETT has been started and is communicating 3 Stopped DETT has been stopped ...

Страница 16: ...em list window The system window provides the following information selections Debug This check box enables or disables the debugging feature of the data export protocol For further details refer to chapter The debug Information Status The status of the connected patient monitoring system is displayed The following states are possible 0 Not connected either LAN or COM ...

Страница 17: ...esses the Association Request and sends an Association Result Type The type of data export connection is displayed Either LAN IEEE802 3 10BaseT 10MBit s Local Area Network or COM RS 232 or RS 232 via USB adapter interface or RS 232 over LAN adapter Name The Associated Name of the patient monitor system or the Interface is displayed LAN If the connected patient monitor uses a label it will be displ...

Страница 18: ...he general details of the selected patient monitor sub menu buttons and a grid displaying numeric data if available The following information is displayed within a tab Bed label displays the associated bed label of the patient monitor if available e g Z0S14 Part number displays the Product Number of the patient monitor e g M8105A Serial number displays the Serial Number of the patient monitor e g ...

Страница 19: ...lows export of data into e g MS Excel The following details are copied and transferred to a spreadsheet Associated Name of the patient monitor system or the Interface Bed label MAC Address LAN connected monitor system Area Application Status Operation Mode Label of the numeric attributes transmitted by the monitor device Respective value of numeric transmitted by monitor device System time PC clie...

Страница 20: ... Data When selecting patient data a new window will be opened displaying the patient data Those details are not copied to the clipboard For details on the ID attributes refer to latest revision of the Data Export Interface Programming Guide ...

Страница 21: ...se 21 MDS Data When selecting MDS data a new window will be opened displaying the connected patient monitor system details For details on the ID attributes refer to latest revision of the Data Export Interface Programming Guide ...

Страница 22: ...indow will be opened displaying the current available Wave parameters and data transmission For details on the ID attributes refer to latest revision of the Data Export Interface Programming Guide The X mark in the column Data indicates the wave data transmission for the respective wave parameter ...

Страница 23: ... patient monitors is selected debug details are displayed in this window Refer to chapter the Menu for further details on how to enable disable the debug mode The presentation of the data reflects the format described in the current revision of the Data Export Interface Guide Within the debug information window the displayed strings can be selected by highlighting and copied to a clipboard This al...

Страница 24: ...more details on how to start The file name is built in one of the following ways 1 Monitor connected to LAN Interface DevIfTest_ Date _ Time _ Bed Label _ MAC Addr txt 2 Monitor connected to COM Interface DevIfTest_ Date _ Time _ COM No _ Baud rate txt The log files contain the communication data in hexadecimal code Each data package is preceded by a header with a time stamp and a communication ty...

Страница 25: ...low shows the DETT with several connected patient monitors In this example one device is selected for debugging The parameter values are displayed in the System Information section and the data stream details are visible in the Debug Information section of the tool window ...

Страница 26: ...etails on how to set up and configure the LAN Interface Connecting to the IntelliVue MP20 90 MIB RS232 Interface Please refer to the current Revision of the IntelliVue Data Export Interface Programming Guide for details on how to setup and configure the MIB RS 232 Interface Connecting an IntelliVue Monitor LAN Interface by using a LAN RS232 converter Please refer to the Instruction for Use of the ...

Страница 27: ...ebug 15 Debug Information Window 21 Deletion of Log Files 7 DETT Instructions for Use 7 DETT overview example 22 F File Configuration 9 File Exit 11 H Help 13 How to connect a PC with DETT to an IntelliVue 23 How to start DETT 8 I Installation of DETT 7 IP 15 L Log Files 21 Log Path 10 M Manufacturer s Information 6 MDS Data 18 N Name 15 NLS 11 P Patient Data 17 S Selectable Buttons within a Tab 1...

Отзывы: