background image

DISASSEMBLY ADVISE IRON

PCS 101 314

BACK PLATE 12

remove  SCREW A

INLAY 1

remove  LAMP 10

remove  MICRO SWITCH 2

ADJUSTMENT AND  CONTROLS

Thermostat 13

Thermostat ( 13 ) supplied as a spare part or fi tted to 

the sole plate ( 9 ) has already been a djusted by the 

supplier and secured by glue.

To avoid disfunction of the iron , NEVER readjust the 

thermostat.

HANDLE 6

remove  THERM. DIAL  4
remove  SCREW B (4x)

unlock  HANDLE carefully

SKIRT 8

remove  ELECTRICAL
 WIRES

remove  EXTENSION 
 PIECE 

5

remove  SPRING CLAMP
 FROM 

STEAM 

HOSE

remove  SCREW C (3x)

Bend back the contact points

THERMOSTAT 13

ONLY

cut 

CONDUCTOR A

 

at location P

remove  SCREW D

P

Q

B

A

D

ASSEMBLY

REQUIREMENTS

THERMOSTAT 2

Instead of metal conductor A, 
the new thermostat has a wire 
with AMP  clamp.
After fi xing screw D, connect 
the AMP clamp to tag Q.
After assembling SKIRT 8 
ALWAYS turn conductor B 
through 180 degrees.

NOTE :

For opening you need a Torx screwdriver 362 TR 

T20 x 100.

Содержание HI 910

Страница 1: ...1 litre length steam hose 1 9 metre length cord set 1 9 metre maximum steam output 50 gr min Voltage 220 240Volt Frequency 50 60 Hz Power consumptium Boiler 1200 Watt Pressure 2 bar Iron 800 Watt 4322 277 00121 99 10 PCS 101 312 Product meets the requirements regarding interference suppression on radio and television After the product has been repaired it should function properly and has to meet t...

Страница 2: ...PCS 101 313 EXPLODED VIEW IRON Screws d x 1 A 3 5 x 12 B 3 5 x 14 3x C M4 x 124 3x B B B C C A DAP0996 3 2 6 13 9 9 14 7 12 5 4 13 11 15 10 1 ...

Страница 3: ...0 01681 9965 000 01682 Handle Rattle Skirt Soleplate Lamp 6 7 8 9 10 9965 000 01683 4822 492 71445 9965 000 01684 9965 000 01685 9965 000 01686 Ball swivel Back plate Thermostat Spring clamp Intermediate cable 11 12 13 14 15 9965 000 01687 9965 002 01689 9965 000 01690 4822 492 71001 9965 000 01691 Safety cut out TABLE UNIT IRON Steam switch Thermostat Thermostat Steam valve ...

Страница 4: ... THERM DIAL 4 remove SCREW B 4x unlock HANDLE carefully SKIRT 8 remove ELECTRICAL WIRES remove EXTENSION PIECE 5 remove SPRING CLAMP FROM STEAM HOSE remove SCREW C 3x Bend back the contact points THERMOSTAT 13 ONLY cut CONDUCTOR A at location P remove SCREW D P Q B A D ASSEMBLY REQUIREMENTS THERMOSTAT 2 Instead of metal conductor A the new thermostat has a wire with AMP clamp After fixing screw D ...

Страница 5: ...EXPLODED VIEW STAND PCS 101 315 E D DAP0998 22 23 21 24 26 27 25 28 30 27 29 31 33 32 34 ...

Страница 6: ...ve LOCKED INSERT 29 NOTE OPEN NOWTHE STAND DON T WORRY IFTHE SNAPS ATTHE SIDE WILL BE BROKEN THEY ARE ONLY FORTHE ASSEMBLY THE STAND REMAINS CLOSE WITHOUTTHESE SNAPS ADJUSTMENT AND CONTROLS To avoid leakage of the sealings and damage to the components in and on the boiler NEVER clean the boiler with vinegar a descaling agent or other chemicals The boiler doesn t contain serviceable parts Never dis...