HD9140/90
2-3
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To disassemble the base cover, remove the 7 screws
(5 of them hidden under the rubber feet).
REPAIR INSTRUCTION
-
Electrical circuit
When the appliance does not work, check the electrical
circuit.
-
Decalcification
Fill the water tank to the MAX level with white vinegar
(8 % acetic acid). Do not use any other type of descaler!
Put the drip tray, all bowls and the lid on the base properly.
Plug in a wall socket and set timer for 25 minutes to begin
steaming.
WARNING:
If vinegar begins to boil over the edge of base,
unplug the unit and reduce the quantity of vinegar slightly.
When the 25 minutes have elapsed, unplug the appliance
and allow the vinegar to cool down before pouring it out.
Rinse the water basin several times with cold water.
Note
: Repeat the procedure if there is still some scale in the
water tank.
-
Cleaning filter
Clean the filter by rinsing it under a running tap.
If necessary, a soft nylon brush can be used.
The filter can also be cleaned by de-scaling it.
Let the filter soak in a cup of warm water with some white
vinegar.
Take the filter out of the cup and rinse it thoroughly.
OPTIONAL (accessories)
- No specific issues.
E
L
N
E
Thermostat
Therm.
Fuse
Control
PCB
220 - 240 V AC
755 - 900 W
or
110 - 127 V AC
755 - 1010 W
PARTS LIST
Pos
Service code
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
4222 459 45357
4222 459 45358
4222 459 45356
4222 459 45363
4222 459 45404
4222 459 45405
4222 459 45364
4222 459 45365
4222 459 45366
4222 459 45406
4222 459 45369
4222 459 45407
4222 459 45367
4222 459 45368
4222 459 45370
Water receiver incl. Supporter
Black
Cover incl. Handle
Black
Steam cap incl. Support
Filter
Rice bowl
Upper steam bowl
Heating element incl. thermostat 220 - 240 V
Heating element incl. thermostat 110 - 127 V
Fuse assy incl. wires
Middle steam bowl
Tube 8*13.4 L = 45mm
Lower steam bowl
Base cover
Rubber foot (1 pc)
Bend pipe