background image

HD9140/90

2-3

DISASSEMBLY- AND  RE-ASSEMBLY ADVISE

-  To disassemble the base cover, remove the 7 screws 

(5 of them hidden under the rubber feet).

REPAIR INSTRUCTION

Electrical circuit

When the appliance does not work, check the electrical 
circuit.

Decalcification

Fill the water tank to the MAX level with white vinegar 
(8 % acetic acid).  Do not use any other type of descaler!
Put the drip tray, all bowls and the lid on the base properly.
Plug in a wall socket and set timer for 25 minutes to begin 
steaming.

WARNING:

  If vinegar begins to boil over the edge of base, 

unplug the unit and reduce the quantity of vinegar slightly.
When the 25 minutes have elapsed, unplug the appliance 
and allow the vinegar to cool down before pouring it out.
Rinse the water basin several times with cold water.

Note

:  Repeat the procedure if there is still some scale in the 

water tank.

Cleaning filter

Clean the filter by rinsing it under a running tap.
If necessary, a soft nylon brush can be used.
The filter can also be cleaned by de-scaling it.
Let the filter soak in a cup of warm water with some white 
vinegar.
Take the filter out of the cup and rinse it thoroughly.

OPTIONAL (accessories)

-  No specific issues.

E

L

N

E

Thermostat

Therm.

Fuse

Control

PCB

220 - 240 V AC
755 - 900 W
           or
110 - 127 V AC
755 - 1010 W

PARTS LIST

Pos

Service code

Description

1
2
3
4
5

6
7

8
9

10
11
12
13
14

4222 459 45357
4222 459 45358
4222 459 45356
4222 459 45363
4222 459 45404

4222 459 45405
4222 459 45364
4222 459 45365
4222 459 45366
4222 459 45406

4222 459 45369
4222 459 45407
4222 459 45367
4222 459 45368
4222 459 45370

Water receiver incl.  Supporter 

Black

Cover incl.  Handle 

Black

Steam cap incl.  Support
Filter
Rice bowl

Upper steam bowl
Heating element incl. thermostat 220 - 240 V
Heating element incl. thermostat 110 - 127 V
Fuse assy incl.  wires
Middle steam bowl

Tube 8*13.4  L = 45mm
Lower steam bowl
Base cover
Rubber foot  (1 pc)
Bend pipe

Отзывы: