HD7825/70 /71 /73
REPAIR INSTRUCTION
Filling procedure:
Please note, the software of the Senseo Viva Café has changed,
compared to predecessor Senseo’s! The fi lling procedure
known from predecessor Senseo’s is no longer available.
The command originally used to initiate the fi lling procedure
(cold fl ush: pushing both the 1-cup and 2-cup buttons
simultaneously) will now start the decalcifi cation process.
To perform a cold fl ush of the appliance, it has to be reset to
factory default. See topic “
Restoring the Boiler_empty_fl ag
to factory default
” below.
As a back-up, when the appliance is in factory default setting,
the cold fl ush will also be initiated when the user presses
either the 1-cup or the 2-cup button. This functionality is
only available after restoring the
Boiler_empty_fl ag
to factory
default.
Restoring the Boiler_empty_fl ag to factory
default
Under some circumstances it might be necessary that the
boiler of the Senseo is emptied.
This, for instance, during wintertime were the possibility
exists that the boiler becomes frozen during transport.
For those occasions it is useful to restore the
Boiler_empty_
fl ag
to production default.
Bringing the Senseo back into production status, has the
benefi t that the fl ush routine will be activated automatically
when installed by the consumer, see topic
Automatic fi lling
procedure
.
To
SET
the
Boiler_empty_fl ag
:
Keep the 1-cup button pressed while plugging in the power
cord of the appliance
.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, you should
reconnect the power cord a second time to the net and push
the main switch.
The main switch LED should light continuously.
4-8