background image

HD7820/60

2-5

Volume adjustment

The new PCB circuit board makes it possible to adjust the 
volume output by means of pushing the one-cup and two-cup 
user controls.
How to adjust the volume output:
1.  Be sure the boiler is fi lled properly, other wise perform fi ll 

procedure see DFU for instructions.

2.  Switch appliance on and wait until the unit is ready to 

brew.

3.  Be sure a 

pod holder

 is placed, but 

without

 a Coffee 

POD.  (Only adjusting with 

plain

 water)

4.  Place a cup on the drip tray cover and push the one-cup 

button.

5.  When the appliance has fi nished it is stabilized to perform 

the volume adjustment. 

6.  Empty the cup, podholder and push again for one cup 

setting, measure the volume output with a graduated 
beaker.  In the table you can fi nd the requirements for 
the minimum / maximum volume output cc/mL values 
depending from the country version:

Min. water cc/mL

Max. water cc/mL

France version

104

120

General version

125

141

7.  Unplug the appliance from the mains.
8.  Press the 1- and 2 cup button simultaneously and plug the 

mains on.

9.  When above step succeeded the LED will turn on 

continuously.

10. Depending if the volume has to de- or increase you have 

to push the 1- or 2 cup button.
Every time you push the 1- or 2 cup button the LED will 
turn off for 0.5 second (feedback to user) and the pump 
time will be shortened or lengthened for 0.5 seconds 
depending which button was pushed.

Pushing 1 cup

 button pump, time will be 

shorten

 with 

0.5 sec is approximately − 3.5 cc/mL  (less coffee)

Pushing 2 cup

 button pump, time will be 

lengthen

 with 

0.5 sec is approxi 3.5 cc/mL  (more coffee)
When the volume has to increase with 10 cc for example, 
push the 

2 cup

 button 3 times.

The new value will be stored when you switch the 
appliance off by pushing the main switch.
(LED will turn off )

11. Turn appliance on again and brew one cup, measure the 

volume.  In case the volume is not within specifi cation 
repeat steps 6 - 11.

12. End.

DISASSEMBLY- AND  RE-ASSEMBLY ADVISE

To remove the back cover, follow below steps:

- Remove Screw 

A

  (see exploded view).

-  Remove valve outlet.
-  Start at the upper side of the back cover and stick a 

screwdriver into the 2 snap locks positions and gently pull 
the back cover from the appliance so that a little chink 
between back cover and brew chamber becomes visible.

-  Put the screwdriver into the 4 rectangular holes (snap locks) 

at the back and gently pull the screwdriver such away that 
the lips of the snap locks are bent outwards.

-  If all clicks positions are loose, it is possible to remove the 

back cover.

-  Reassemble follow steps backwards.

To reach the components placed on the base (for example 
exchange the NTC temperature sensor) follow below steps:

-  First remove back cover, brew chamber, 3-way valve and 

boiler.

- Remove both Torx T15 screws 

B

  (see exploded view).

-  Bend the 2 click snap locks with a screwdriver (see base), 

the housing can now be removed.

-  To remove the rest of the housing unlock the last 4 snap 

locks at the base and gently pull of the front cover.

-  To reassemble follow above steps backwards.

OPTIONAL (accessories)

-

  No specific issues.

REPAIR INSTRUCTION

Descaling

Regular descaling will prolong the life of your appliance and 
will guarantee optimal brewing results for a long time.
•  Follow the steps in the section headed “Preparing the 

appliance for use” see DFU (Direction for Use manual)

•  Instead of only water use a mix of water and Lemon sour.
•  For the best result leave the mix of water and Lemon sour 

for about 30 Minutes in the appliance, before you start with 
flushing the appliance.

•  To get the best results repeat above-mentioned step once or 

twice.

•  When finished, flush the appliance twice by repeating the 

above-mentioned steps only use water instead.