Repair instruction for replacing switch:
If the switch has to be replaced please follow the next steps:
• Remove bottom base plate.
• Pull the complete pump unit (including hose pieces) downwards until the hose
pieces are loosened from the two water tank pipes. (hose pieces and wires
must stay connected to the pump).
• Remove the complete top cover including the water tank. (see picture 1)
• Now it is possible to get to the switch.
• To remove the switch from the housing, follow the steps see pictures below.
• The new switch can be placed on the same way, to do so follow the above steps backwards!
• Insert the complete top cover assy including plastic tank gently back into the housing.
• Take the pump unit and attach the hose pieces to the water tank pipes of the previously inserted tank.
(be sure that the hose pieces are well attached to the water tank pipes, otherwise leakage problems can occur)
• Assemble the base plate again.
Transportation lock:
To prevent damaging the dosing/weighting system in case the appliance has to
be shipped/transported, It is possible to order a special transportation lock.
For the position of the transportation lock see picture 2.
The code number transportation lock: 4222 247 59510
Commercial trade number jug + lid: HD7965/81 (frost grey)
picture 1
START
POSITION
1
MID
POSITION
2
END
POSITION
3
PRESS
IN THIS
DIRECTION
PULL AND
ROTATE
CLOCKWISE
MOVE THE
SWITCH IN
THIS DIRECTION
HOUSING
PART
SMALL
DETENT
PIECE A
4222 247 59510
picture 2