10
Functions/features explanation
Normal Coffee volume routine adjustment: (General 122 ml / French/Spanish 100 ml version)
1. Unplug the appliance from the mains.
2. Make sure the
water tank
is
filled
and
placed
on the machine.
(for adjusting the right parameter, the internal
SW
will check if the
water level sensor
is
activated
yes/no.)
3. Press the 1- and 2-cup button simultaneously and plug the mains on.
4. When above step succeeded the led will turn on continuously.
5. Depending if the volume has to de- or increase you have to push the one- or two-cup button.
Every time you push the 1- or 2 cup button the LED will turn off for 0.5 second (feedback to user) and
the pump time will be shortened or lengthened for 0.5 seconds depending which button was pushed.
Pushing 1-cup
button pump, time will be
shorten
with 0.5 sec is approximately - 3.5 cc/ml (less coffee)
Pushing 2-cup
button pump, time will be
lengthen
with 0.5 sec is approxi 3.5 cc/ml (more
coffee)
When the volume has to increase with 10 cc for example, push the
2-cup
button 3 times.
The new value will be stored when you switch the appliance off by pushing the on/off switch.
(LED will turn off)
6. Turn appliance on again and brew one cup, measure the volume. In case the volume is not within
specification repeat steps 1 - 5.
Strength select coffee volume routine adjustment: (General 60 ml / French/Spanish 60 ml version)
Adjusting the scale factor, the scale factor is a factor that ensures the small volume used for the “general-”
and “French/Spanish-” version is correctly applied between the versions.
Adjusting the scale factor for the strong/short (60ml) cup volume.
1. Place an empty
water tank
on the machine.
(for adjusting the right parameter, the internal
SW
will check if the
water level sensor
is
activated
yes/no)
2. Press the 1- and 2 cup button simultaneously and plug the mains on.
3. Release the 1- and 2 cup button, if successful, the on/off LED will switch on less bright/intense as
normal, indicating the scale factor reprogramming has entered.
4. Depending if the volume has to de- or increase you have to push the one- or two-cup button.
Every time you push the 1- or 2-cup button, the LED will turn off for 0.5 second (feedback to user) and
the scale factor will be shortened or lengthened depending which button was pushed.
Pushing 1-cup
button, scale factor will be
shorten
approximately - 1 cc/ml (less coffee)
Pushing 2-cup
button, scale factor will be
lengthen
approxi 1 cc/ml (more coffee)
The new value will be stored when you switch the appliance off by pushing the main switch.
(LED will turn off)
5. Turn appliance on again and brew one strong coffee cup by pressing the 1-cup button twice, measure
the volume. In case the volume is not within specification repeat steps 1 – 4.