INTELIA 07 DISASSEMBLY
Saeco International Group
Rev. 01 / September 2011
Page / 11
7.9. Pump
7.10. Flow-meter
Lift the
fl
ow meter out of the casing assembly and
remove the electrical and water circuit connections.
Loosen the screws as
illustrated, slide out the
electrical connection and
remove the card guard.
Slide the card off the
support and disconnect the
electrical connections.
Disconnect the water circuit connections (A) and
electrical connections (B), loosen the safety valve
(C) and slide the pump off the brackets (D).
06
7.11. Control board
A
B
D
D
C
A
A
7.12. Water sensor control board
Slide the card off the
support.
Slide out the pipe
connecting the
fl
ow
meter to the pump.
Loosen the screw as illustrated and
remove the capacitive sensor glued to
the seat.
Содержание HD 8753
Страница 3: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 1 INTRODUCTION ...
Страница 9: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Страница 13: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 3 USER INSTRUCTIONS ...
Страница 19: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 4 OPERATING LOGIC ...
Страница 28: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 5 TROUBLESHOOTING ...
Страница 40: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 6 STANDARD CHECKS ...
Страница 43: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 7 DISASSEMBLY ...
Страница 55: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 8 NOTES ...
Страница 56: ...INTELIA 08 NOTES Saeco International Group Rev 01 September 2011 Page 01 01 ...
Страница 57: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 9 WATER CIRCUIT DIAGRAM ...
Страница 60: ...Saeco International Group Rev 01 September 2011 INTELIA CHAPTER 10 ELECTRICAL DIAGRAM ...
Страница 61: ...INTELIA 10 WIRING DIAGRAM Saeco International Group Rev 01 September 2011 Page 01 01 Intelia Focus and Class ...