background image

Warning high leakage current earth connection

essential before connecting supply 

(5.1.7.1 of IEC60950-1)

1.5 mm

2

1000 W

2.5 mm

2

4 mm

2

6 mm

2

2000 W

Less then 20 m

20 to 40 m
40 to 60 m
60 to 80 m

Less then 35 m

35 to 60 m
60 to 85 m

85 to 120 m

FLOODLIGHT

CONNECTION

1.2 Nm

1

2

1

2

1.2 Nm

Exercise appropriate care in the handling of high voltages. Do not touch any conductive parts during operation.

Ensure the units are disconnected from the mains before exchanging the lamp connected to the PSU / ignitor resp. in to the end application. The residual charge

left on the capacitors is a danger to life if the units are still connected to mains!

Caution: The residual charge on the capacitors can be a danger to life even if the units are disconnected from the mains. Please handle with care!

Both electronic lamp ballast and ignitor must never be installed or operated in an explosive or volatile atmosphere. Never use the ballast or ignitor near 

flammable

gases or liquids. See that there will be no moisture, dust or similar which could lead to short circuits or fire.

Before using the ballast or ignitor in any kind of outdoor application you have to take additional measures and observe special requirements. If you are uncertain,

contact Philips.

No potential isolation is provided between line input and output. Accidentally grounding of an output terminal by direct contact or arcing to GND can damage

the unit (no warranty replacement).

The unit is designed for case mounting. Due observation of electrical safety and RFI suppression code requirements is mandatory in all applications.

See that sufficient cooling of EPS and ignitor is provided.

All installation and repair work on this unit is only permitted by qualified personnel. Always comply with local safety requirements when operating the unit

uncased.

Extreme care must be taken when testing the unit live. The use of an isolating transformer is mandatory. On no account may grounded test instruments / meters

be used for this purpose!

Philips does not assume liability for disregarding of this notice, incorrect use of the EPS and ignitor or dis-regarding of any legal requirements.

This product is subject to technical changes without prior notice.

It is essential to isolate the electronic ballast/ignitor or the connected luminaire electrically from mains voltage before maintenance !

Do not attempt to handle or operate an electronic power supply (EPS) and ignitor before completely reading and understanding this notice. 

Contact Philips if you are uncertain of hazards associated with these devices.

The Ballast and the ignitor produces starting voltages of up to 11 kV and electromagnetic radiation interference which are hazardous to 

personnel and sensitive instrumentation.

*) After under voltage protection activation, driver start again 

when Umains return to nominal value

After over voltage protection activation, driver start again when 

Umains will off during 30 sec. and then return to nominal value.

Behavior after over temperature shutdown: Automatic restarting 

after cool down.

4411 102 68142

12/2014

Data subject to change

Printed in France

www.philips.com/lighting

2/2

Main supply must be fused according to local safety regulations. Philips 

recommends 2-phase fuse protection (fuses are not provided by 

Philips).

The appropriate fuse value can be calculated as:

Plamp ×1,5/Vin    Ifuse    Plamp ×1,2/Vin