background image

GC8320

9-9

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

HOSE-CORD ASSY 3

 or 

CORDSET 55

, they must be replaced. 

Continued usage is not allowed.

-  When replacing the 

MICROSWITCH ASSY 9

, please dress the 2 attached wires such that they are free of tension. Pulling force 

on the wires may affect the steam triggering.

-  To avoid damage to the sealing & components of the 

BOILER ASSY 38

NEVER

 clean the boiler assy with vinegar, descaling 

agent or other corrosive chemicals.

- When replacing 

ELECTROVALVE 40

 or 

PUMP ASSY 45

, please be reminded to apply loctite at the joints for good sealing.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. 
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

REPAIR INSTRUCTIONS

Содержание GC8320

Страница 1: ... TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1370 W Dimension F box 350 x 350 x 250 mm L x W x H Weight with packing 6 4 kg Water advice If the tap water in your area is very hard it is advisable to mix the tap wate...

Страница 2: ...2 DISASSEMBLY ADVICE IRON INLAY 4 STEAM LOCK 6 LAMP ASSY 7 MICROSWITCH ASSY 9 SWITCH HOLDER 10 PIVOT HOLDER 11 TRIGGER 12 THERMOSTAT DIAL ASSY 14 HOUSING PRINTED 16 SOLEPLATE COVER 17 THERMOSTAT BUSH 19 RUBBER HOSE 25 BRASS JOINT 21 SOLEPLATE ASSY 23 Remove Screw A Disassemble BACKPLATE 1 Release Inlay rear catch Disassemble INLAY 4 Disassemble STEAM LOCK 6 Disassemble SWITCH HOLDER 10 Disassemble...

Страница 3: ...4239 026 08280 4239 026 21820 4239 021 36861 4239 021 31790 4239 026 21780 4239 026 21790 4239 026 21800 4239 010 09290 4239 021 35310 4239 021 51430 4239 021 32870 4239 015 70150 4239 026 13220 4239 010 10280 4239 021 41330 4239 015 56120 4239 015 56510 4239 026 24180 4239 021 31780 4239 010 10110 Backplate Purple Hose cord mounted assy Inlay SOS Lamp cover Steam lock Lamp mounted assy Microswitc...

Страница 4: ...GC8320 4 9 EXPLODED VIEW IRON 6 5 13 22 4 26 9 10 11 16 17 27 24 19 23 25 21 2 7 12 14 1 3 18 A S N L E B1 B2 D3 Hose clip a Hose clip b E2 D2 C D1 E1 E3 28 22 ...

Страница 5: ... FRONT PANEL PRINTED 37 M1 M2 M3 12 11 10 9 Pos Connected to Pos Connected to 9 Reed switch 11 Thermistor 10 Power board 12 Hosecord Black Fig 5 Connections on CONTROL BOARD 44 DISASSEMBLY ADVICE STAND DETACHABLE WATER TANK Remove Connections 9 10 11 12 Fig 5 Remove Screws M1 M2 M3 Fig 5 Disassemble CONTROL BOARD 44 21 20 15 14 18 13 22 16 17 19 Pos Connected to Pos Connected to 13 Pump Control 18...

Страница 6: ...55990 Tray rubber Main Tray rubber Rear Tray Stand top assy White Nipple plate Front panel printed Boiler assy EE C Wall Electrovalve Braided rubber hose Inox clamp Power board Control board Pump assy Boiler rubber support A Boiler rubber support B Pos Service code Description 50 51 52 53 54 55 56 59 60 61 62 63 64 66 4239 015 56050 4239 026 22330 4239 022 62500 4239 021 31820 4239 026 22050 4239 ...

Страница 7: ...GC8320 7 9 EXPLODED VIEW STAND 35 30 31 33 34 45 62 60 49 61 63 64 41 42 K4 K2 K1 K3 M2 L2 L1 M3 M1 J1 J2 J3 59 37 39 3 43 55 49 53 54 48 56 20 38 47 46 52 51 50 44 40 66 ...

Страница 8: ...GC8320 8 9 EXPLODED VIEW PARTS LIST DETACHABLE WATER TANK N1 N2 N3 70 Pos Service code Description 70 4239 021 35320 Water tank assy Purple ...

Страница 9: ...1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elasta...