background image

GC8280

9-9

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

HOSE-CORD ASSY 3

 or 

CORDSET 55

, they must be replaced. 

Continued usage is not allowed.

-  To avoid damage to the sealing & components of the 

BOILER ASSY 38

NEVER

 clean the boiler assy with vinegar, descaling 

agent or other corrosive chemicals.

- When replacing 

ELECTROVALVE 40

 or 

PUMP ASSY 45

, please be reminded to apply loctite at the joints for good sealing.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. 
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

REPAIR INSTRUCTIONS

Содержание GC8280

Страница 1: ...ould function properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1370 W Dimension F box 350 x 350 x 250 mm L x W x H Weight with packing 6 4 kg Water advice If the tap water in your area is very hard it is advisable to mix the tap water with an equal amount of demineralised water...

Страница 2: ... C5 Disassemble POWER BOARD CAP 13 INLAY 4 SIQ CONTROLLER 11 DISASSEMBLY ADVICE IRON Fig 3 Rear catch of INLAY 4 Release Rear catch of INLAY 4 Fig 3 Disassemble INLAY 4 Fig 4 Inlay mounted assy D1 D2 Remove Screws D1 D2 Fig 4 Disassemble SIQ CONTROLLER 11 HOUSING 12 SOLEPLATE COVER 15 HEAT BARRIER 16 BRAIDED RUBBER HOSE 18 THERMISTOR ASSY 22 SOLEPLATE ASSY 23 Remove Screw C1 Disassemble HOUSING 12...

Страница 3: ...6 21880 4239 021 32940 4239 021 32590 4239 026 22320 4239 015 56210 4239 015 55970 4239 026 21810 4239 021 42260 4239 021 31880 4239 026 22140 4239 015 53580 4239 021 32190 4239 026 21750 4239 015 70150 4239 015 56540 4239 010 09350 4239 010 10280 4239 010 10110 4239 021 18120 4239 021 43520 Backplate IQ moulded Swivel Green Hose cord assy IQ Inlay IQ Soft Touch Display cap assy Temperature button...

Страница 4: ...GC8280 4 9 EXPLODEDVIEW IRON 4 5 5 10 16 8 9 15 14 17 2 1 6 7 19 13 12 18 11 21 20 3 22 23 Hose clip H F2 E1 F1 B1 C2 E3 C1 E2 C3 B2 C5 D1 D2 A C4 G ...

Страница 5: ...L PRINTED 37 M1 M2 M3 12 11 10 9 Pos Connected to Pos Connected to 9 Reed switch 11 Thermistor 10 Power board 12 Hosecord Black Fig 6 Connections on CONTROL BOARD 44 DISASSEMBLY ADVICE STAND DETACHABLE WATERTANK Remove Connections 9 10 11 12 Fig 6 Remove Screws M1 M2 M3 Fig 6 Disassemble CONTROL BOARD 44 21 20 15 14 18 13 22 16 17 19 Pos Connected to Pos Connected to 13 Pump Control 18 Electrovalv...

Страница 6: ...ear Tray rubber Front Tray Safe storage Stand top Green Nipple plate Cord storage lever Green Front panel printed IQ Boiler assy EE C Wall Electrovalve Braided hose Inox clamp Power board Control board Pump assy Inlet tube De air tube Pos Service code Description 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 4239 015 55980 4239 015 55990 4239 015 56050 4239 026 22490 4239 022 56490 4239 02...

Страница 7: ...GC8280 7 9 EXPLODEDVIEW STAND 58 35 30 31 32 33 34 36 45 44 62 60 49 61 63 64 41 42 K4 K2 K1 K3 M2 L2 L1 M3 M1 J1 J2 J3 59 37 40 39 3 43 55 49 53 54 48 57 56 20 38 47 46 52 51 50 65 ...

Страница 8: ...n 70 71 72 73 74 4239 021 32960 4239 026 22130 4239 015 55390 4239 026 22110 4239 015 56060 Water tank assy Green Tank washer Sealing ring Tank coupling Tank coupling seal Pos Service code Description 75 76 77 78 4239 026 22540 4239 010 09330 4239 015 56070 4239 021 31860 Tank lever Green Spring Pick up tube Filter assy ...

Страница 9: ...Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate vis...

Отзывы: