EXPLODED VIEW
C
D
E
F
B
A
3
2
1
4
5
8
9
6
101
11
10
13
14
15
12
102
103
16
Screws :
d x l
A,B,C,D,E
3.5 x 16.5
mm
4.0 x 9.0 mm (with washer)
G
4.0
x
9.0
Страница 1: ...se However if the tap water in your area is very hard we advise you to mix it with a equal portion of distilled water or to use distilled water only Soleplate Ceralon the name indicates the strong combination of a non stick coating lon blended with ceramic Cera particles The soleplate is coated with Ceralon material which is smooth gliding high scratch resistance and good durability advantage over...
Страница 2: ...e Screw A 1x Remove Backplate 1 Remove Screw B 2x cord clamp Remove Cord set 3 Remove Dosing unit 5 Remove Screw D 1x Remove Operation knob 4 Remove Screw C 2x Remove Inlay 6 Remove Dial 10 Remove Screw E 1x Remove Tank set 12 Remove Screw F 3x Romove Cover 14 RESISTOR LAMP FUSE N L E HEATING UNIT INPUT THERMOSTAT 1 Backplate 4822 441 12291 2 Swivel 4822 325 10229 3 Cordset EU 4239 000 08070 4 Ope...
Страница 3: ...EXPLODED VIEW C D E F F F B B C A 3 2 1 4 5 8 9 6 101 11 10 13 14 15 12 102 103 16 Screws d x l A B C D E 3 5 x 16 5 mm F 4 0 x 9 0 mm with washer G 4 0 x 9 0 mm ...
Страница 4: ...he typenumber onto the typeplate with a sharp object 2 Parts with numbers from 100 and higher cannot be ordered seperately 3 After the product has been repaired it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment ADJUSTMENTS AND CONTROLS Thermostat Thermostat fitted to the soleplate 16 has already been adj...