HX6942/14, HX6942/20,
HX6962, HX6972, HX6992
6/2009
3-4
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
-
UV light bulb replacement
1.
Unplug sanitizer.
2.
Pull the drip tray straight out.
4.
Remove light bulb by grasping it and pulling it out of
the metal clasp.
5.
Align replacement light bulb with metal clasp and push
bulb into clasp then reinsert light bulb screen.
OPTIONAL (accessories)
-
No specific issues
5.
The rechargeable battery can now be recycled and the rest
of the product discarded appropriately.
1.
To deplete the rechargeable battery of any charge,
remove the handle from the charger, turn on the Sonicare
and let it run until it stops. Repeat this step until you can
no longer switch on the Sonicare.
3.
Hold the handle upside down
and push down on the shaft
to release the internal
components of the handle.
2.
Insert a screwdriver into the
slot located at the bottom of
the handle and turn
counterclockwise to release
the bottom cap.
4.
Insert the screwdriver under
the circuit board, next to the
battery connections, and
twist to break the
connections. Remove the
circuit board and pry the
battery from the plastic
carrier.
3.
To remove the
screen, grasp the
edges next to the
snaps, gently
squeeze and pull
out the protective
screen..