FC9722/09 / FC9722/19
4-11
•
After removing the two buttons remove the 4 screws
B
at the back and the 5 screws
C
at the front of the upper
housing (see pictures).
•
Screw
D
at the front does not need to be removed, this
screw is for ESD and is located in the lower housing.
B
B
B
B
D
C
C
C
C
C
•
To replace the potmeter (
9
) situated at the bottom
of the upper housing, remove knob (
7
) on top of the
upperhousing and remove the 2 scews
E
at the bottom
of the upper housing (see picture).
E
E
•
After removing the upperhousing, Hose connection (
10
)
and Bucket inlet sealing (
13
) are accessible. To replace
the hose connection screw
F
has to be removed.
F
•
To replace Cordwinder (
24
) or Motor (
31
) Motor housing
(
28
) has to be removed, this can be done by removing
the 4 screws
G
(see picture).
Remark:
A special long screw driver is needed!
H
H
G
G
G
G
•
To replace the PCB (
9
) remove the 2 short screws
H
.