background image

FC9060

DISASSEMBLY- AND  RE-ASSEMBLY ADVISE

-  To open the apliance, 

First remove the filter cover 
(

item 24

) then remove the 

vario knob button (

item 11

with a screwdriver as shown 
in the picture.

-  To remove the button panel (

item 13

), first loosen 

mounting screws (

A

), now by using a screwdriver unlock 

the 4 snap connection and separate the panel from the 
housing. (see picture)

-  Display cover (

item 12

) now can easely be removed from 

the button panel.)

-  To remove the motor, you need a torx screwdriver with a 

14.5cm long shank. Screwdriver 9965 000 08332 can be 
used.

REPAIR INSTRUCTION

-  Cotton dustbags, are used in countries in which paper 

dustbags are not available.

-  If the reel half spring unit is replaced, shaft 

G

 must be 

lubricated with 

silicone grease

.  Do not apply any silicone 

grease to or spill any grease on terminals (

39

) or conductors 

(

38

).

Item 37

 is provided with a long cord-winder spring, but 

both long and short cords can be used in combination with 
this spring.  (L = 9.3 m)

-  Depending on the original cord, the spare cord must be 

shortened to the length of the original cord.

-  The cord winder spring must be tensioned to the maximum 

level and then be rewound approx. 1.5 turn 

Item 10

, air valve, opens to cool the motor if the air 

displacement is too low or if the airflow is blocked.

-  To adjust the telescopic tube (

item 46

) to the required 

length, push the adjustment collar in the direction of the 
arrow while sliding the top section of the telescopic tube 
into or out of the lower section.

-  If the function of the electronic control unit (

item 15

) is 

not required, the Triac must be short-circuited in the 
manner shown in the circuit diagram. 

-  When the vacuum cleaner is used to suck up fine dust the 

pores of the dustbag may become clogged, causing the 
passage of air through the dustbag to become obstructed. 
As a result, the dustbag-full indicator will indicate that the 
dustbag needs to be replaced, eventhough the dustbag is not 
full at all.

ELECTRICAL DIAGRAM

Triac

iac

Short-circuit

t

Short-circui

circu

Short-circuit

MOTOR
POWER

MODULE

Black

Black/White

Brown

Blue

CORD WINDER

M

2-7

Содержание FC9060

Страница 1: ...cuum 300 mbar 30 0 kPa Type number dustbag FC8021 Duststorage capacity 3 L Cord length 7 m Fiter system Double layered compatible s bag 3 layer permanent motor protection filter Super Clean Air exhaust filter Dimensions of cleaner 449 x 324 x 250 mm Dimensions of packaging 593 x 393 x 296 mm Net weight 5 7 kg ACCESSORIES Nozzle Tri Active all purpose nozzle Tubes Metal lacquered telescopic tubes A...

Страница 2: ...ion with this spring L 9 3 m Depending on the original cord the spare cord must be shortened to the length of the original cord The cord winder spring must be tensioned to the maximum level and then be rewound approx 1 5 turn Item 10 air valve opens to cool the motor if the air displacement is too low or if the airflow is blocked To adjust the telescopic tube item 46 to the required length push th...

Страница 3: ...le Filter cover lock Light grey Filter cover fr Light Blue Electrostatic filter Phoenix Pos Service code Description 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 4322 001 73360 4322 000 38790 4322 003 23220 4322 000 38760 4322 000 38770 4322 003 23880 4322 001 73520 4322 001 73400 4322 006 97940 4322 000 38820 4322 003 23870 4322 009 07940 4322 009 07950 4322...

Страница 4: ...FC9060 EXPLODEDVIEW 2 5 6 9 8 10 7 3 4 11 12 14 48 15 16 9 13 A B B B B B B A A Y Black White Black Z brown blue 1 4 7 ...

Страница 5: ...FC9060 EXPLODEDVIEW C C C C C C C C C D 21 20 19 18 17 28 27 26 25 24 23 22 29 30 5 7 ...

Страница 6: ...FC9060 EXPLODEDVIEW 32 35 39 36 37 38 E F F F F E E G Z brown blue 40 41 34 50 Black White Y Black 31 33 6 7 ...

Страница 7: ...FC9060 EXPLODEDVIEW 47 Europe Ø 4 8mm 41 Swiss Italy 40 U K H K 43 42 44 51 52 53 45 49 46 7 7 ...

Отзывы: