INSTALLATION INSTRUCTIONS 
F Series Floodlight 

 

 
 
 
 
 

© 2016  Philips Lighting Holding B.V.  All rights reserved. 

www.philips.com/luminaires

 

Part Number 443561002550 Rev.  F 

Page 

3

 of 

7

 

 
 

FIXTURE WIRING 

This fixture must be wired in accordance 
with the NEC and applicable local codes.  

 
WARNING:  Proper  grounding  is 
required to insure personal safety.  

Connect the green or bare copper fixture-
ground  lead  to  a  suitable  ground 
connector.  Use  approved  connectors  for 
all electrical connections. 

 

 

 

 
 
 
STEP 6 

Unscrew  and  remove  the  cable 
connector nut from cable connector on 
side 

of 

ballast 

mastfitter, 

(See 

FIGURE  5

).  Remove  the  rubber 

grommet  from  cable  connector  body. 
Slide  cable  connector  nut  up  the  S.O. 
cord,  then  slide  the  rubber  grommet 
approximately  3”  up  the  S.O.  cord. 
Insert  S.O.  cord  into  cable  connector 
body,  then  attach  and  securely  tighten 
the cable connector nut to         15 ft-
lbs. 
 

STEP 7 

Remove  inspection  plate  and  gasket 
from  back  of  mastfitter  by  removing 
the two screws (See 

FIGURE 5

).  

Mount  fixture/ballast  assembly  to  2-
3/8” OD vertical pipe tenon (by others) 
after  pushing branch circuit lead wires 
(by  others)  through  the  mastfitter  and 
out  inspection  plate  opening.  Service 
may  also  be  made  by  removing  the 
1/2”  pipe  plug from the mastfitter and 
attaching a proper watertight connector 
(by  others),  and then inserting an S.O. 
cord with branch circuit lead wires (by 
others).  Tighten  the  two  3/8”  square 
head  set  screws  on  the  side  of  the 
mastfitter  against  the  pipe  tenon  to  8 
ft-lbs. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 

 

Содержание F Series

Страница 1: ...will VOID THE WARRANTY GENERAL Upon receipt inspect for any freight damage which should be brought to the attention of the delivering carrier See Damage and Shortage Claims for proper steps in filing claims with the carrier Compare the catalog description listed on the packing slip with the label on the carton to assure you have received the correct material This floodlight is designed for outdoor...

Страница 2: ...cket housing gasket is seated properly and then tighten the screws securely E OR ED SHAPED LAMPS This lamp shape is primarily found in 400 watt size lamps The BT stabilux collar must be removed before installing an E or ED shaped lamp This is accomplished by compressing the BT split collar by hand and removing from the fixture Inside the stabilux cavity of the fixture there is a E lamp stabilux fo...

Страница 3: ...nnector body Slide cable connector nut up the S O cord then slide the rubber grommet approximately 3 up the S O cord Insert S O cord into cable connector body then attach and securely tighten the cable connector nut to 15 ft lbs STEP 7 Remove inspection plate and gasket from back of mastfitter by removing the two screws See FIGURE 5 Mount fixture ballast assembly to 2 3 8 OD vertical pipe tenon by...

Страница 4: ...dlight Follow steps 1 through 3 above Next attach the U bracket to the ballast mastfitter as shown in FIGURE 6 CAUTION the two holes in the bracket for the 3 4 long bolts must be toward the top as shown in FIG 6 Mount fixture to the U bracket and attach the three 3 8 16 mounting bolts and lock washers IMPORTANT The 1 2 long bolt is centered over the fixture flange and to the bottom of the mount Ti...

Страница 5: ...osite fixture lens There are five 9 16 mounting holes for securing the PX 1 to the cross member three of which can be utilized without bolt interference These are the two on top and the lower horizontal hole in the back plate As a minimum these three holes must be utilized Mounting hardware 1 2 bolts provided by user See FIGURE 10 PM Wood Pole Mounting Brackets Aluminum wood pole mounts with verti...

Страница 6: ...MF 1 using hardware as covered in steps 4 and 5 of fixture assembly Remove pipe plug from MF 1 and route S O cord through a watertight cable connector provided by user for internal wiring to the remote ballast Or wiring can be external to an appropriate junction box or similar device See FIGURE 17 HV 1 Trunion Base for Less Ballast Models Can be mounted to any suitable horizontal or vertical surfa...

Страница 7: ...om and back for 3 4 NPT conduit Gasket provided for sealing box to the WB 1 Mounting hardware 1 2 mounting bolts provided by user The WB 5 box is supported by the same bolts used to support the WB 1 and need to be long enough to secure both the WB 1 and box to the wall The box straddles the four mounting bolts See FIGURE 20 TH 1 Hanger for Less Ballast Models For mounting floodlights on standard l...

Отзывы: