Philips ELI-S-20 Скачать руководство пользователя страница 2

>  The backup micro inverter will be located between the AC power sources and the AC ballast/driver as shown in  

wiring diagram section of instructions.

>  NOTE: The backup micro inverter may be installed in close proximity to the fixture or remote from the fixture. 

The maximum remote distance using 16 AWG wire is 250 ft. Contact the factory for more information.

>  The AC power is fed to the backup micro inverter.  

>  The AC ballast/driver receives power from the backup micro inverter. Identify the output wires of the backup 

micro inverter by the presence of the orange/black and yellow/black leads.

NOTE:  Make sure that the necessary branch circuit wiring is available. An unswitched 

source of power is required. The unswitched and switched power source must be fed 
from the same branch circuit.

warning: to prevent high voltage From Being present on the orange/BlacK 

anD yellow/BlacK oUtpUt leaDs prior to installation, inverter connector 

mUst Be open. Join inverter connector aFter installation is complete anD ac 

power is sUpplieD.

installing the BacKUp micro inverter

>  Disconnect all power sources from lighting fixture and ensure they are locked out during installation or  

maintenance.

>  Disconnect power leads from the AC ballast/driver.

>  Select a suitable location for the backup micro inverter and install such that its output leads can connect to 

the input leads of the AC ballast/driver.  

>  See Illustration 1, for typical installation and select appropriate mounting method.

step 1

Disconnect ac power From FixtUre

INSTALLATION

2

>  Verify that the inverter connector (red and white) is disconnected. Note that the unswitched hot connects to 

the black input lead of the backup micro inverter.

step 2

connect the BacKUp micro inverter to the proper line voltage

wiring the BacKUp micro inverter

>  Use the wiring diagram found on page 4 as reference.

>  Connect the AC power source leads to the input of the backup micro inverter.

>  Connect the output leads of backup micro inverter to the AC ballast/driver. 

>  Wire the AC ballast/driver with the lamp in accordance with manufactures installation instructions. No ballast/

driver is necessary for incandescent lamp application.

>  Make sure all connections are in accordance with the National Electrical Code, Canadian Electrical Code and 

any local regulations.

>  Connect the indicator LED by matching violet and brown leads.

>  In a readily visible location, attach the label “CAUTION–This Unit Has More Than One Power Connection Point. 

To Reduce The Risk Of Electric Shock, Disconnect Both The Branch Circuit-Breakers Or Fuses And DC Power 

 

Supply (Backup Ballast Inverter Connector) Before Servicing.”

step 3

Содержание ELI-S-20

Страница 1: ...ters 8 This product is for use with indoor or damp locations where ambient temperature is 0 C to 50 C Not suitable for wet or hazardous locations 9 This is a sealed unit Integral battery is not replaceable Replace entire unit when necessary 10 The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition 11 Do not use this product for other than intended use 12 S...

Страница 2: ...he AC ballast driver Select a suitable location for the backup micro inverter and install such that its output leads can connect to the input leads of the AC ballast driver See Illustration 1 for typical installation and select appropriate mounting method STEP 1 Disconnect AC power from fixture INSTALLATION 2 Verify that the inverter connector red and white is disconnected Note that the unswitched...

Страница 3: ... for 1 hour Charge for 24 hours before conducting a long term discharge test Refer to OPERATION Illustration 1 The T BAR mounting bracket assembly is sold separately and is available from the factory as an accessory kit T BAR MB Call your local distributor or the factory for complete information T BAR BRACKET M I C R O I N V E R T E R 1 2 4 3 4 TEST MONITOR PLATE INSTALLATION Backup Micro Inverter...

Страница 4: ... ensure that it is working The following schedule is recommended 1 Visually inspect the charging indicator light monthly It should be illuminated 2 Test the emergency operation of the fixture at 30 day intervals for a minimum of 30 seconds The lamp should operate at full illumination 3 Conduct a 90 minute discharge test once a year The lamp should operate at full illumination for at least 90 minut...